Item | Fused Terminal Block |
Amps | 6 A |
Max. Wire Size | 10 AWG |
Min. Wire Size | 26 AWG |
Voltage | 500V AC |
Number of Poles | 1 |
Number of Connections | 2 |
Terminal Type | Lever-Type Fuse, No Lamp |
Depth | 2.85 in |
Width | 0.32 in |
Standards | CSA Certified, CURus, EAC |
Description/Special Features | Accepts 5 x 20mm Glass or Ceramic Fuse |
Pieces per Foot | 50 |
Block Material | Polyamide 6/6 |
Color | Black |
Temp. Range | -76 Degrees to 266 Degrees F |
Connection Type | Screw Clamp |
Channel Size | 35mm |
Mounting Type | DIN |
Height | 2.22 in |
Length | 72.5 mm |
Material | polyamide 6/6 insulating case |
Overall Length | 2.85 in |
For Maximum Wire Size | 10 AWG |
Circuit Protection Type | Fuse |
Termination Style | Screw |
For Conductor Type | Solid, Stranded |
Special Features | Accepts 5 x 20mm Glass or Ceramic Fuse |
End Barrier Compatibility | Not Applicable |
Maximum Voltage | 600 V AC |
Wire Size Ranges | 26 AWG - 10 AWG |
RoHS Compliant | Yes |
Terminal Block Type | Fused Disconnect |
Overall Depth | 2.85 in |
Housing Material | Polyamide 6/6 |
Overall Width | 0.32 in |
For Minimum Wire Size | 26 AWG |
Strip Length | 5/16 in |
Housing Color | Black |
Terminal Material | Copper |
UL 94 Flammability Rating | V-0 |
Current | 6 A |
Maximum Operating Temperature | 266 Degrees F |
Termination Screw Size | M3 |
For Conductor Material | Copper |
Number of Tiers | 2 |
For Channel Rail Size | 35mm |
Torque | 7 lb-in |
Minimum Operating Temperature | -40 Degrees F |
Dielectric Loss | 0.01 at 1 MHz IEC 60250 || 0.01 at 1 MHz VDE 0303-T4 |
Range | Linergy |
Cable Cross Section | 0.2-4 mm?, flexible without cable end || 0.2-4 mm?, solid or flexible with cable end |
Resistivity | 10000 ?.cm IEC 60093 || 10000 ?.cm VDE 0303-T30 |
Tool Type | connection screwdriver || disconnection screwdriver |
Surface Resistance | 1000 MOhm IEC 60093 || 1000 MOhm VDE 0303-T30 |
Tightening Torque | 0.5-0.8 N.m |
Number Of Terminals | 2 |
Range Compatibility | Prisma G || Prisma P || Prisma PH || Prisma Pack || Spacial || Kaedra || Pragma || TeSys |
Ambient Air Temperature For Operation | -40-130°C IEC 60216-1 || -40-130°C VDE 0304-T21 |
Product Name | Linergy TR |
Product Or Component Type | terminal block |
Product Certifications | cURus || CSA || EAC |
Device Short Name | TRV |
Product Compatibility | Spacial enclosures |
[Ue] Rated Operational Voltage | 500 V EN/IEC 60947-7-1 || 600 V cURus || 600 V CSA |
Dielectric Constant | 3.7 at 1 MHz |
Fuse Size | 5 x 20 mm |
Connection Position | sideways |
Connections - Terminals | 1 x screw terminal upstream || 1 x screw terminal downstream |
Line Rated Current | 6.3-6.3 A EN/IEC 60947-7-1 || 12-12 A cURus || 6.3-6.3 A CSA |
Dielectric Strength | 1000 V IEC 60243-1 |
Flame Retardance | V0 0.8 mm UL 94 |
Terminal Block Level | 1 |
Number Of Measurement Input | 0 |
Device Application | protection |
Nominal Cross Section | 4 mm? |
Wire Stripping Length | 8 mm |
Mounting Mode | clip-on |
Creep Resistance | 500 CTI (> 400 kB) IEC 60093 || 500 CTI (> 400 kB) VDE 0303-T30 |
Country of Origin (subject to change) | Turkey |
Package Quantity | 1 |
Terminal Block, Screw Clmp Tech Fused Blk, SCHNEIDER ELECTRIC, Mfr# NSYTRV42SF5
$8.88
Free shipping will be applied on orders over $50
Fused Terminal Block, Circuit Protection Type Fuse, Connection Type Screw Clamp, Current 6 A, For Minimum Wire Size 26 AWG, For Maximum Wire Size 10 AWG, Housing Color Black, Maximum Voltage 600 V AC, Mounting Type DIN, Number of Poles 1, Number of Tiers 2, For Conductor Material Copper, For Conductor Type Solid, Stranded, Overall Depth 2.85 in, Overall Length 2.85 in, Overall Width 0.32 in, Standards CSA Certified, CURus, EAC, Terminal Block Type Fused Disconnect
9999 in stock
Must order in multiples of 1
Subtotal:
$8.88
You must be logged in to post a review.
Reviews
There are no reviews yet.