VA Rating - UPS Systems
1.0 kVA
Output Voltage
115/120V AC
Backup Time (Half/Full Load)
28 min/10 min
Special Features
Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output, Extended Runtime w/BP36V15-2U, BP36V42-3U
Green Environmental Attribute
Product Contributes To Reducing Energy Consumption
NEMA Plug Configuration
5-15P
Standards
CSA, FCC Part 15 Category A (EMI), UL 1778, UL60601-1 (Medical Grade)
Includes
PowerAlert Software and Cables
Automatic Volts Regulation
Yes
NEMA Receptacle Configuration
(4) 5-15R
Fax/Modem Line Protection
No
Green Certification or Other Recognition
UL1778 (USA, Series AGSM1200PSR3HG), UL2601-1 (Medical), cUL (Canada), FCC Class A (emissions), Conforms to IEEE 587 / ANSI C62.41 specifications
Capacity - Batteries
1000 VA/750 W
Operating Temp. Range
104u0026deg;F (40u0026deg;C)
Battery Type
Sealed Lead Acid (SLA)
Input Connection
6 ft Cord with NEMA 5-15P-HG Plug
Internal UPS Replacement Battery Cartridge
RBC36SLT
Severe Undervoltage Correction
Input voltages between 81 and 95 are boosted by 21%
Output Volt Amp Capacity (VA)
1000
UPS Input Cord Length (ft.)
6
Relative Humidity
0 to 95%, non-condensing
Installation Form Factors Supported with Optional Accessories
Wallmount (UPSWM - tower mounting kit)
Primary UPS Depth (mm)
241
Battery Mode BTU / Hr. (Full Load)
315.2
Half Load Runtime (min.)
28 min. (375w)
Leakage Current
Less than 100 microamps
EMI / RFI AC Noise Suppression
Yes
Battery Access
Battery access door
Grounding Lug
Grounding lug (equipotential)
Input Circuit Breakers
15A
Nominal Output Voltage(s) Supported
115V; 120V
Output AC Waveform (Battery Mode)
PWM sine wave
High Availability UPS Features
Hot swappable batteries
Output Watt Capacity (Watts)
750
Output Voltage Regulation (Line Mode)
-18%, +8%
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions
Overvoltage Correction
Input voltages between 126 and 143 are reduced by 9%
AC Suppression Joule Rating
940
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Expandable Battery Runtime
Extended runtime supported via optional external battery packs
Rated input current (Maximum Load)
9.2A
Low Voltage Transfer to Battery Power (Setpoint)
81
DC System Voltage (VDC)
36
Battery Recharge Rate (Included Batteries)
Less than 4.5 hours from 10% to 90%
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Output kVA Capacity (kVA)
1
Recommended Electrical Service
15A 120V
Nominal Input Voltage(s) Supported
120V AC
PowerAlert Software
For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert
Output Receptacle Details
Hospital grade output receptacles
Communications Interface
USB; DB9 Serial
Full Load Runtime (min.)
10 min. (750w)
Frequency Compatibility
60 Hz
Individually Controllable Load Banks
No
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade)
High Voltage Transfer to Battery Power (Setpoint)
143
Output Voltage Regulation (Battery Mode)
115V (+/- 5%)
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
UPS AC Suppression Response Time
Instantaneous
External Battery Pack Compatibility
BP36V15-2U (limit 1); BP36V27-2US (multi-pack compatible); BP36V42-3U (multi-pack compatible)
AC Mode BTU / Hr. (Full Load)
162.8
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
UPS AC Suppression Joule Rating
940
Undervoltage Correction
Input voltages between 96 and 106 are boosted by 10%
Output Isolation Transformer
Hospital grade load isolation transformer
Battery Replacement Description
Hot-swappable, user replaceable batteries
Primary UPS Height (mm)
318
Communications Cable
USB and DB9 serial cabling included
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
UPS Power Module Dimensions (hwd, in.)
12.5 x 7.5 x 9.5
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible Alarm
Factory-muted audible alarm indicates power-failure, overload and low-battery conditions
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
AC Mode Efficiency Rating (100% Load)
0.94
Package Contents
SmartPro 1200XLHG UPS, SMART 1200XLHG Medical Grade Tower UPS System, PowerAlert Software and cabling, Warranty information, Instruction manual
Maximum Operating Temperature
104°F (40°C)
Additional Information
Ideal UPS protection for applications in medical patient-care areas where UL 2601-1 listed medical electrical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Built-in isolation transformer with faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes, Provides connected equipment with continuous power during short and long duration loss of commercial power, Expandable runtime is available with the addition of one or more external battery packs (part# BP36V27), Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation prevents shock potential and operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 1000VA / 750 watts, 34 minutes half load runtime (500VA/375 watts), 16 minutes full load runtime (1000VA/750 watts), 4 protected hospital-grade outlets; 6-ft. cord, 1-RS-232 and 1-USB serial port for network interface; SNMP compatible, SNMP compatible with separate purchase SNMPWEBSOLO ethernet adapter accessory, Complete surge protection, line isolation and EMI/RFI noise filtering, 2 year product warranty, PowerAlert unattended shutdown software and complete cabling included, 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload u0026 battery low/replace, Battery replacement door, Back panel grounding lug
Network Management
SNMP Manageable
Load Capacity
1000 VA/750 W
Certifications u0026 Standards
UL1778 (USA, Series AGSM1200PSR3HG), UL2601-1 (Medical), cUL (Canada), FCC Class A (emissions), Conforms to IEEE 587 / ANSI C62.41 specifications
Backup/Run Time (Half Load)
28 Minute
Status Indicators
Includes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning
Alarm
On Battery, Low Battery, Overload
Battery Chemistry
Lead Acid
Typical Battery Recharge Time
4 Hour
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
315.2
UPS Applications
Hospital/Medical
Output Capacity (Watts)
750
Product Compliance
FCC Part 15 Class A (USA)
Product Certifications
CSA (Canada); UL 1778; UL 60601-1
Installation Form Factors Supported with Included Accessories
Tower
Grounding Details
Grounding lug (equipotential)
Package Includes
SMART1200XLHG 1kVA/750W Medical-Grade Tower UPS System;USB monitoring cable, 6 ft.;DB9 serial monitoring cable, 6 ft.;PowerAlert Software;Owner's Manual
Country of Origin (subject to change)
China