Center Line Pipe Center Size
3 5/8 in
Electrical Connections
1/2
Valve Design
2-Way/2-Position
Valve Configuration
Normally Closed
Body Material - Valves
Brass
Seal Material - Valves
NBR
Environmental Rating - Valves
Indoor, Outdoor
Valve Ways and Positions
2-Way/2-Position
NEMA Rating
1, 2, 3, 3S, 4, 4X
Application
Air Compressors, Car Wash, Industrial Water Control, Laundry Equipment, Pumps
Max. Fluid Temp.
180 Degrees F
Media
Air/Inert Gas and Water
Coil Enclosure
Watertight No Junction Box
Max. Operating Pressure Differential Light Oil
Not Rated
Max. Operating Pressure Differential Water
125 psi
Max. Operating Pressure Differential Air/Inert Gas
150 psi
Min. Operating Pressure Differential
5 psi
Operation Type
Pilot Operated
Operating Pressure Differential Water - Minimum
5 psi
Operating Pressure Differential Air/Inert Gas - Maximum
150 psi
Operating Pressure Differential Steam - Minimum
Not Applicable
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Valve Positions
2-Position
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Operating Pressure Differential Liquid CO2 - Minimum
Not Applicable
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
Operating Pressure Differential Hot Water - Minimum
Not Applicable
NEMA Enclosure Rating
1, 2, 3, 3S, 4, 4X
Operating Pressure Differential Liquid CO2 - Maximum
Not Applicable
Operating Pressure Differential Fuel Oil - Maximum
Not Applicable
Ambient Temperature - Minimum
14 Degrees F
Operating Pressure Differential Light Oil - Minimum
Not Applicable
Operating Pressure Differential Air/Inert Gas - Minimum
5 psi
For Media
Air, Inert Gases, Light Oil, Water
Operating Pressure Differential Cryogenic Fluid - Minimum
Not Applicable
Operating Pressure Differential - Minimum
5 psi
Operating Pressure Differential Cryogenic Fluid - Maximum
Not Applicable
Valve Starting Configuration
Normally Closed
Ambient Temperature - Maximum
140 Degrees F
Operating Pressure Differential Fuel Oil - Minimum
Not Applicable
Operating Pressure Differential - Maximum
150 psi
Operating Pressure Differential Light Oil - Maximum
Not Rated
Environmental Rating
Indoor, Outdoor
Coefficient of Volume (Cv)
2.2
Fluid Temperature - Maximum
150 Degrees F
Outlet Connection Type
NPTF
Operating Pressure Differential Water - Maximum
125 psi
Mounting Orientation
Vertical
Inlet Connection Type
NPTF
Operating Pressure Differential Steam - Maximum
Not Rated
Operating Pressure Differential Hot Water - Maximum
Not Rated
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Country of Origin (subject to change)
Mexico