| Property | Value |
|---|---|
| Item | Meter Main |
| Main Circuit Breaker or Main Lug | Main Lug |
| Number of Spaces | 20 |
| Amps | 200A |
| Phase | 1 |
| Short Circuit Current Rating | 22kA |
| Height | 39.80 in |
| Width | 16.80 in |
| Depth | 3.40 in |
| Series | SC |
| Max. No. of Tandem Breakers | 20 |
| Mounting Style | semi flush outdoor) |
| Circuit Breaker Type | Homeline |
| Hub type | A-L |
| Wire Size | AWG 8...AWG 2/0 aluminium/copper)service ground || AWG 4...250 kcmil aluminium/copper)line side |
| Number Of Circuits | 40 |
| Meter Socket Type | ringed |
| Service Disconnect Rated Current | 200 A |
| Product Compatibility | solar ready |
| Tightening Torque | main lugs 250 lb.in, AWG 4...250 kcmil, aluminium/copper || service ground 50 lb.in, AWG 14...AWG 2/0, copper || service ground 50 lb.in, AWG 12...AWG 2/0, aluminium || branch lugs 50 lb.in, AWG 14...AWG 4, copper || branch lugs 50 lb.in, AWG 12...AWG 2, aluminium || branch lugs 35 lb.in, AWG 6...AWG 4, aluminium/copper || branch lugs 25 lb.in, AWG 8, aluminium/copper || branch lugs 20 lb.in, AWG 14...AWG 10, aluminium/copper || branch lugs 20 lb.in, AWG 12...AWG 10, aluminium/copper || Cover 10 lb.in |
| Electrical Connection | lugs line side || lugs service ground |
| Ground Bar Kit | service disconnect (factory installed) |
| Bypass Type | no bypass |
| Country of Origin (subject to change) | Mexico |
| Package Quantity | 1 |
Meter Main, SC, 20 Spaces, 200A, Main Lug, 1 Phase, Square D, Mfr#: SC2040M200PF