Includes
Audible Continuity Check, Resettable Overload Protection Circuit, Test Leads with Alligator Clips
Sensitivity
20K ohm/V DC, 5K ohm/V AC
Accuracy
V AC: +/-3% Full Scale, V DC: +/-2% Full Scale
AC Frequency Response
60 Hz
Movement
Taut-Band, Mirrored Scale
Special Features
Large Tri-Colored Dial with Mirrored Scale to Prevent Parallax Error
Basic AC Voltage Accuracy
+/-3.00%
Minimum DC Current Measurement
50 uA
Battery Voltage
1.5V DC; 9V DC
Maximum Resistance Measurement
20 megaohm
Maximum DC Voltage Measurement
1,000 V
Basic AC Current Accuracy
+/-3.00%
Minimum Sound Level Measurement
-20 dB
Minimum AC Voltage Measurement
2.5 V
Calibration Certificate Included
No
Parameters Measured
AC Voltage, DC Current, DC Voltage, Resistance
Minimum Resistance Measurement
0 microohm
Basic DC Current Accuracy
+/-1.50%
Maximum DC Current Measurement
10 A
Minimum DC Voltage Measurement
250 V
Basic DC Voltage Accuracy
+/-2.00%
Maximum AC Voltage Measurement
1,000 V
Maximum Sound Level Measurement
50 dB
Resistance Measurement Accuracy
Rx1 2.5 Degrees of Arc, Rx100 2.0 Degrees of Arc, Rx10000 2.0 Degrees of Arc
Country of Origin (subject to change)
United States