Promotion Restriction | Not eligible for promotion |
Item | Digital Clamp Meter |
Digital/Analog | Analog, Digital |
Max. AC Amps | 2,500 A |
Clamp Meter Jaw Style | Plier |
Max. DC Volts | 1,000 V |
Max. Ohms | 60 kilohm |
Jaw Capacity | 1.3 in (34mm) |
Temp. Range | -4 Degrees to 158 Degrees F, -40 Degrees to 158 Degrees F |
Safety Rating | IEC 61010-1, IEC 61010-2-032: CAT III 1000 V/CAT IV 600 V, IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V |
Display | LCD |
Jaw Opening | 1.38 in |
Max. DC Amps | 999.9 A |
Max. AC Volts | 1,000 V |
Calibration Frequency | 5 to 500 Hz |
Data Logging | Yes |
Bar Graph | No |
Midscale Resistance | 30,000 ohm |
Frequency Counter | 200 kHz |
Special Features | 4 Gripping Points for Pulling Round Objects, Log and Trend Measurements to Pinpoint Intermittent Faults, Secure Hold by Aggressive Serrated Jaws and 4-Point Gripping Hole, Side Cutting Edge for Wire Cutting, Straight, Half-Round, Long and Slim Knurled Jaws, Specially Profiled, Transmit Results Wirelessly Via Fluke Connect Measurements App, True-Rms Voltage and Current for Accurate Measurements on Non-Linear Signals, Unique Milled Wave Pattern Gripping Zones |
Capacitance | 9,999 uF |
Max. Conductor Size | 34 mm |
Non-Contact Voltage Detector | No |
Manufacturers Warranty Length | Lifetime |
Audible Continuity | Yes |
Operating Temp. | 14 Degrees to 122 Degrees F |
Memory | 65,000 Readings, Data Hold, Max/Min, Max/Min/Avg |
Peak Hold | No |
Inrush | Yes |
Standards | CSA, IEC 61326-1, IEC 61326-2-2, T?V, UL, VDE Listed |
Auto Power Off | Yes |
Counts | 6000 |
Battery Type | Alkaline |
AC Response | TRMS |
AC Current Accuracy | 1.5% +/-5 Digits |
Data Hold | Yes |
Auto Ranging | Yes |
Calibration Certificate | No |
Includes | (1 Pair) TL75 Test Leads, (2) AA Batteries (Installed), 18 in iFlex Flexible Current Probe, Fluke 376 FC True-RMS Clamp Meter, Fluke Insulated High Leverage Diagonal Cutter 8 in, 200mm, 1000V, Fluke Insulated Linesman Combination Plier 8 in, 200 mm, 1000V, Fluke Insulated Long Nose with Side Cutter 8 in, 200mm, 1000V, Fluke Insulated Phillips Screwdriver #1 3 in, 75 mm, 1000V, Fluke Insulated Phillips Screwdriver #2 4 in, 100 mm, 1000V, Fluke Insulated Slotted Screwdriver 1/4x5 in, 6 mm x 125 mm, 1000V, Fluke Insulated Slotted Screwdriver 3/32x3 in, 2.5 mm x 75 mm, 1000V, Fluke Insulated Slotted Screwdriver 5/32x4 in, 4 mm x 100 mm, 1000V, Quick Reference Guide, Roll Up Pouch, Soft Carrying Case, TPAK Magnetic Hanging Strap |
Diode Test | Yes |
DC Voltage Measurement Resolution | 0.1 mV |
Intrinsically Safe | Yes |
Maximum Resistance Measurement | 50 megaohm |
Maximum Frequency Measurement | 200 kHz |
Battery Chemistry | Alkaline |
Jaw Style | Plier |
Battery Access | Yes |
Frequency Measurement Resolution | 0.01 Hz |
Basic DC Voltage Accuracy | +/-1% |
Basic AC Current Accuracy | +/-3.00% |
AC Voltage Measurement Resolution | 0.1 V |
Display Type | LCD |
Basic AC Voltage Accuracy | +/-1.5% |
Resistance Measurement Accuracy | +/-1.00% |
Thermal Imaging | No |
Batteries Included | Yes |
Battery Size | AA |
Maximum Operating Temperature | 1,994 Degrees F |
AC Current Measurement Resolution | 0.1 A |
Minimum Operating Temperature | 14 Degrees F |
Maximum Storage Temperature | 140 Degrees F |
AC Response Calculation | TRMS |
Dustproof | No |
Minimum Capacitance Measurement | 0.1 uF |
Instrument Counts | 6,000 |
Bluetooth Compatible | Yes |
Capacitance Measurement Accuracy | +/-1.00% |
DC Current Measurement Resolution | 0.01 uA |
Resistance Measurement Resolution | 0.1 ohm |
Basic DC Current Accuracy | 2 % |
Maximum AC Current Measurement | 2,500 A |
Parameters Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance |
Minimum Storage Temperature | -40 Degrees F |
Maximum AC Voltage Measurement | 1,000 V |
Capacitance Measurement Resolution | 0.1 uF |
Maximum DC Current Measurement | 999.9 A |
Bar Graph Included | No |
Waterproof | No |
Inrush Current Measurable | Yes |
Maximum Capacitance Measurement | 9,999 uF |
Calibration Certificate Included | No |
Current Leakage Testing | No |
Maximum Conductor Size | 34mm |
Removable Screen | No |
Frequency Measurement Accuracy | +/-0.005% |
IP Rating | IP30 |
Maximum DC Voltage Measurement | 1,000 V |
Country of Origin (subject to change) | Singapore |
Package Quantity | 1 |
Clamp Meter Kit, LCD, 2,500 A A, 1.3 in (34mm) Jaw Capacity, FLUKE, Mfr# FLK-376FC-IFLEX36
$735,99
Free shipping will be applied on orders over $50
Digital Clamp Meter, Audible Continuity Yes, Safety Rating IEC 61010-1, IEC 61010-2-032: CAT III 1000 V/CAT IV 600 V, IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V, AC Response Calculation TRMS, Maximum AC Current Measurement 2,500 A, Maximum AC Voltage Measurement 1,000 V, Maximum DC Current Measurement 999.9 A, Maximum DC Voltage Measurement 1,000 V, Current Leakage Testing No, IP Rating IP30, Parameters Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance
9999 in stock
Must order in multiples of 1
Subtotal:
$735.99
You must be logged in to post a review.
Reviews
There are no reviews yet.