Controller, 24VDC, 4.17 in. H, Compact, SCHNEIDER ELECTRIC, Mfr# TM221C24R

$438,99
Free shipping will be applied on orders over $50

Controller, Input Voltage 24V AC/DC, Output Type Relay, 2 A Amps, Number of Inputs 24, Number of Outputs 24, No Clock, 7 Segment LED Display, Depth 5.47 in, Height 4.17 in, Width 6.1 in

9999 in stock

Must order in multiples of 1
Subtotal:
$438.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: TM221C24R
Availability: Ships in 5 days
SKU: GRG9372133 Category:
ItemController
Input Voltage24V AC/DC
Output TypeRelay
Amps2 A
Number of Outputs24
ClockNo
Display7 Segment LED
Number of Inputs24
Depth5.47 in
Height4.17 in
Width6.1 in
Response Time35 µs turn-off, I2 to I5 input || 10 ms turn-on output || 10 ms turn-off output || 5 µs turn-on, I0, I1, I6, I7 fast input || 35 µs turn-on, other terminals input || 5 µs turn-off, I0, I1, I6, I7 fast input || 100 µs turn-off, other terminals input
StandardsEN/IEC 61010-2-201 || EN/IEC 60664-1 || EN/IEC 61131-2
Electrical Durability100000 cycles AC-12, 120 V, 240 VA, resistive || 100000 cycles AC-12, 240 V, 480 VA, resistive || 300000 cycles AC-12, 120 V, 80 VA, resistive || 300000 cycles AC-12, 240 V, 160 VA, resistive || 100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive || 100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive || 100000 cycles DC-12, 24 V, 48 W, resistive || 300000 cycles DC-12, 24 V, 16 W, resistive || 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms) || 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Resistance To Electrostatic Discharge8 kV in air EN/IEC 61000-4-2 || 4 kV on contact EN/IEC 61000-4-2
Counting Input Number4 fast input (HSC mode) 100 kHz 32 bits
Discrete Input Logicsink or source (positive/negative)
Reset Time1 s
Discrete Output Current2A
Discrete Output Number10 relay
Mounting Supporttop hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Exct Time For Event Task60 µs response time
Maximum Cable Distance Between Devicesshielded cable <10 m fast input || unshielded cable <30 m output || unshielded cable <30 m digital input || unshielded cable <1 m analog input
Resistance To Fast Transients2 kV EN/IEC 61000-4-4 power lines) || 2 kV EN/IEC 61000-4-4 relay output) || 1 kV EN/IEC 61000-4-4 I/O) || 1 kV EN/IEC 61000-4-4 Ethernet line) || 1 kV EN/IEC 61000-4-4 serial link)
Voltage State 0 Guaranteed<= 5 V input
Minimum Load1 mA 5 V DC relay output
Transmission Rate1.2 to 115.2 kbit/s (115.2 kbit/s by default) 15-15 m RS485 || 1.2 to 115.2 kbit/s (115.2 kbit/s by default) 3-3 m RS232 || 480 Mbit/s USB
Operating Altitude0 to 6561.68 ft (0 to 2000 m)
Resistance To Magnetic Fields30 A/m 50/60 Hz EN/IEC 61000-4-8
Storage Altitude0-3000 m
Electrical Connectionremovable screw terminal block for inputs || removable screw terminal block for outputs || terminal block, 3 for connecting the 24 V DC power supply || connector, 4 for analogue inputs || mini B USB 2.0 connector for a programming terminal
Insulationbetween input and internal logic 500 V AC || non-insulated between analogue input and internal logic || non-insulated between analogue inputs || between supply and ground 1500 V AC || between sensor power supply and ground 500 V AC || between input and ground 500 V AC || between output and ground 1500 V AC || between supply and internal logic 2300 V AC || between sensor power supply and internal logic 500 V AC || between output and internal logic 2300 V AC || between Ethernet terminal and internal logic 500 V AC || between supply and sensor power supply 2300 V AC
Mechanical Durability20000000 cycles relay output
Product CertificationsCSA || LR || ABS || IACS E10 || DNV-GL || RCM || cULus || EAC
Data Backed Up256 kB built-in flash memory backup of application and data
Memory capacity256 kB user application and data RAM 10000 instructions || 256 kB internal variables RAM
Backup Time1 year 25 °C by interruption of power supply)
Electromagnetic Emissionconducted emissions 79 dB??V/m QP/66 dB??V/m AV power lines (AC))0.15-0.5 MHz EN/IEC 55011 || conducted emissions 73 dB??V/m QP/60 dB??V/m AV power lines (AC))0.5-300 MHz EN/IEC 55011 || conducted emissions 120 to 69 dBµV/m QP power lines)10-150 kHz EN/IEC 55011 || conducted emissions 63 dB??V/m QP power lines)1.5-30 MHz EN/IEC 55011 || radiated emissions 40 dB??V/m QP class A 10 m)30-230 MHz EN/IEC 55011 || conducted emissions 79 to 63 dB??V/m QP power lines)150-1500 kHz EN/IEC 55011 || radiated emissions 47 dB??V/m QP class A 10 m)200-1000 MHz EN/IEC 55011
Maximum Current Per Output Common4 A COM 2 || 7 A COM 0 || 7 A COM 1
Clock Drift<= 30 s/month 25-25 °C
Vibration Resistance3.5 mm 5-8.4 Hz symmetrical rail || 3.5 mm 5-8.4 Hz panel mounting || 1 gn 8.4-150 Hz symmetrical rail || 1 gn 8.4-150 Hz panel mounting
Resistance To Electromagnetic Fields10 V/m 80 MHz to 1 GHz EN/IEC 61000-4-3 || 3 V/m 1.4 GHz to 2 GHz EN/IEC 61000-4-3 || 1 V/m 2 to 2.7 GHz EN/IEC 61000-4-3
Execution Time Per Instruction0.2 µs Boolean
Discrete Input Voltage24 V
Conversion Time1 ms per channel + 1 controller cycle time analog input
Configurable Filtering Time0 ms input || 3 ms input || 12 ms input
Regulation Loopadjustable PID regulator up to 14 simultaneous loops
Pollution Degree<= 2
Power Supply Output Current0.52-0.52 A 5 V expansion bus || 0.16-0.16 A 24 V expansion bus
Permitted Overload On Inputs+/- 30 V DC 5 min maximum)analog input || +/- 13 V DC permanent)analog input
Realtime Clockwith
Lsb Value10 mV
Communication Port ProtocolUSB port USB - SoMachine-Network || non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
Sensor Power Supply24-24 V DC 250 mA supplied by the controller
Integrated Connection TypeUSB port mini B USB 2.0 || non isolated serial link serial 1 RJ45 RS485 || non isolated serial link serial 2 RJ45 RS232/RS485
[Us] Rated Supply Voltage100 to 240 V AC
Surge Withstand2 kV power lines (AC) common mode EN/IEC 61000-4-5 || 2 kV relay output common mode EN/IEC 61000-4-5 || 1 kV I/O common mode EN/IEC 61000-4-5 || 1 kV shielded cable common mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) differential mode EN/IEC 61000-4-5 || 1 kV power lines (AC) differential mode EN/IEC 61000-4-5 || 1 kV relay output differential mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) common mode EN/IEC 61000-4-5
Supplyserial)serial link supply 5 V, <200 mA
Ip Degree Of ProtectionIP20 with protective cover in place
Resistance To Conducted Disturbances10 V 0.15 to 80 MHz EN/IEC 61000-4-6 || 3 V 0.1 to 80 MHz Marine specification (LR, ABS, DNV, GL) || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Analogue Input Resolution10 bits
Execution Time For 1 Kinstruction0.3 ms event and periodic task
Analogue Input Number2 0 to 10 V
Discrete Input Current7 mA discrete input || 5 mA fast input
Ambient Air Temperature For Operation-10-55 °C horizontal installation) || -10-35 °C vertical installation)
Relative Humidity10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Local Signallingfor PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for SL1 1 LED (green) || for SL2 1 LED (green) || for I/O state 1 LED per channel (green)
Environmental Characteristicordinary and hazardous location
Immunity To Microbreaks10 ms
Maximum Number Of I/O Expansion Module7 (local I/O-Architecture) || 14 (remote I/O-Architecture)
Data Storage Equipment2 GB SD card optional)
Voltage State 1 Guaranteed>= 15 V input
Discrete Input Voltage TypeDC
Input Impedance3.4 kOhm discrete input || 100 kOhm analog input || 4.9 kOhm fast input
Discrete I/O Number24
Shock Resistance98 m/s? 11 ms
Network Frequency50/60 Hz
Discrete Output Voltage5 to 125 V DC || 5 to 250 V AC
Maximum Power Consumption In Va55 VA 100 to 240 V with max number of I/O expansion module || 32 VA 100 to 240 V without I/O expansion module
Control Signal TypeA/B || single phase || pulse/direction
Supply Voltage Limits85-264 V
Protection Typewithout protection 5 A
Discrete Input Number14 , discrete input IEC 61131-2 Type 1
Output Voltage Limits125 V DC || 277 V AC
Inrush Current40 A
Battery TypeBR2032 lithium non-rechargeable 4 year(s)
Switching Frequency20 switching operations/minute with maximum load
Maximum Size Of Object Areas255 %C counters || 8000 %MW memory words || 512 %M memory bits || 512 %KW constant words || 255 %TM timers
Absolute Accuracy Error+/- 1 % of full scale analog input
Discrete Output Typerelay normally open
MarkingCE
Product Or Component Typelogic controller
Ambient Air Temperature For Storage-25-70 °C
Country of Origin (subject to change)Taiwan, Province of China
Package Quantity1
TAGS:
#Controller
#24VDC
#4.17 in. H
#Compact
#SCHNEIDER ELECTRIC
#Mfr TM221C24R
#SCHNEIDER ELECTRIC
#GRG9372133
#mfr:TM221C24R
#part number:TM221C24R
#pn:TM221C24R
#part code:TM221C24R
#item number:TM221C24R
#product code:TM221C24R
#manufacturer number:TM221C24R
#manufacturers part number:TM221C24R
#mfn:TM221C24R

Reviews

There are no reviews yet.

Add a review