Brand Name: SCHNEIDER ELECTRIC
Mfr #: RM35JA32MW
Availability: Ships in 5 days
SKU: GRG0572111 Category:
Item - RelayCurrent Sensing Relay
ItemCurrent Sensor Relay
Coil Volts250VAC/DC
StandardsEN/IEC 60255-6
Width35 mm
Input VoltageCurrent Sensing Relay
Supply Voltage Limits20.4-264 V AC/DC
Minimum Switching Current10 mA 5 V DC
Maximum Measuring Cycle30 ms measurement cycle as true rms value
Reset Time1500 ms time delay
Measurement Error0.05 %/°C with temperature variation || 1 by volt over the whole range with voltage variation
Maximum Switching Voltage250 V AC/DC
Polarityno DC
Product Or Component Typecurrent control relay
Operating Positionany position without derating
Housing Materialself-extinguishing plastic
Run-Up Delay At Power-Up0.3 s
Threshold Setting10...100 %
Maximum Power Consumption In Va3.5 VA AC
Repeat Accuracy+/- 0.5 % input and measurement circuit || +/- 2 % time delay
Ambient Air Temperature For Operation-20-50°C
Dielectric Test Voltage2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
Relay Monitored Parametersovercurrent or undercurrent detection
Utilisation CategoryAC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
MarkingCE : EMC 89/336/EEC || CE : 73/23/EEC
Pollution Degree3 IEC 60664-1
[Ui] Rated Insulation Voltage250 V IEC 60664-1
Electrical Durability100000 cycles
Non-Dissipating Shock Wave4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
Relay Typecurrent control relay
Product CertificationsGL || UL || GOST || C-tick || CSA
Shock Resistance15 gn 11 ms IEC 60255-21-1
Resistance Across Terminals0.005 Ohm E3-M terminals || 0.015 Ohm E2-M terminals || 0.05 Ohm E1-M terminals
Insulation Resistance> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 || > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 || > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
Electromagnetic Compatibilityemission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2
Mechanical Durability30000000 cycles
Mounting Support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Local Signallingfor power ON LED (green) || for relay ON LED (yellow)
Maximum Power Consumption In W0.6 W DC
Tightening Torque0.6-1 N.m IEC 60947-1
Output Contacts2 C/O
Measurement Range0.15...1.5 A E1-M terminals || 0.5...5 A E2-M terminals || 1.5...15 A E3-M terminals || 150 mA...15 A current
Control Circuit Voltage Limits15 % + 10 % Un
Connections - Terminalsscrew terminals, 1 x 0.5...1 x 4 mm? AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm? AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm? AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16) flexible with cable end
Maximum Switching Current5 A AC/DC
Vibration Resistance0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
Ip Degree Of ProtectionIP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
Contacts Type And Composition2 C/O
Contacts Materialcadmium free
Hysteresis5-50 % threshold setting
Measurement Accuracy+/- 10 % of the full scale value
Immunity To Microbreaks50 ms
Ambient Air Temperature For Storage-40-70°C
Relay NameRM35JA
[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz +/- 10 %
Relative Humidity95-95 % 55-55°C IEC 60068-2-30
Operating Rate<= 360 operations/hour full load
Time Delay Typeadjustable 1...20 s, 0 + 10 % on energisation Ti || adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt
Nominal Output Current5A
Switching Capacity In Va1250 VA
Overvoltage CategoryIII IEC 60664-1
Control Circuit Frequency40...70 Hz +/- 10 %
Time DelayAdjustable 1 to 20 s, 0 + 10% on energisation Ti, Adjustable 0.3 to 30 s, 0 + 10% on crossing the threshold Tt
Rated Supply Voltage24 to 240 V AC/DC 50/60 Hz +/- 10%
Operating Voltage Tolerance- 15% + 10% Un
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#Current Relay 250V 5Amp Rm35
#SCHNEIDER ELECTRIC
#Mfr RM35JA32MW
#SCHNEIDER ELECTRIC
#GRG0572111
#mfr:RM35JA32MW
#part number:RM35JA32MW
#pn:RM35JA32MW
#part code:RM35JA32MW
#item number:RM35JA32MW
#product code:RM35JA32MW
#manufacturer number:RM35JA32MW
#manufacturers part number:RM35JA32MW
#mfn:RM35JA32MW

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!