Item - Relay
Current Sensing Relay
Input or Control Voltage
120V AC
AC Contact Rating - Relay
10A @ 240V
DC Contact Rating - Relay
8A @ 28V
Sensing Amp Range
0.10 to 10.00A
Core Type - Relay
Internal
Electrical Connection
Terminal Strip
Status Indicator
LED Indicator
Operating Current
0.05-1 A, 0.5-10 A, 5-100 A
Electrical Operating Durability
100,000
Trip Point Type
Adjustable
Monitored Parameters
Overcurrent
Minimum Operating Temperature
-18 Degrees F
Contact Rating (AC)
10 A @ 240V
Contact Rating (DC)
7 A @ 28V
Mechanical Operating Durability
10,000,000
Maximum Operating Temperature
149 Degrees F
Standards
cULus Listed, cURus
Load (Burden)
Less than 5VA for all voltages
Sensing Delay On Power
0.1 - 10 seconds
Voltage Tolerance
AC Operation: +10/-15% of nominal at 50/60 Hz.
Pick-up u0026 Drop-out
Fixed 100ms
Three built-in current ranges to monitor both AC u0026 DC current
5 -100ma DC (3.5 - 70.7ma AC); 0.05 - 1A DC (0.035 - 0.707A AC); and 0.5 - 10A DC (0.35 - 7.07A AC)
Configuration / Contact Rating
SPDT. 10A @ 240V AC / 7A @ 28V DC SPDT, 1/4 HP @ 120V AC (N.O.)
Output Contacts
10A @ 240V AC / 7A @ 28V DC SPDT, 1/4 HP @ 120V AC (N.O.)
Indicator LED
Green when Input Voltage is applied; Red when Relay is energized
Temperature
-28oto 65oC (-18oto 149oF)
Function
Overcurrent AC/DC
Current Range
DC: 5 -100mA, 0.05 - 1A, and 0.5 - 10A ; AC: 3.5 - 70.7mA, 0.035 - 0.707A, and 0.35 - 7.707A
Life
Mechanical: 10,000,000 operations; Full Load: 100,000 operations
Enclosure Style
Plug-in case utilizing industry-standard 11 pin octal sockets, Plug-in
Sensing delay on power-up ts
0.1 - 10 seconds
Country of Origin (subject to change)