Item | Definite Purpose Magnetic Contactor |
Full Load Amps-Inductive | 20 A |
Full Load Amps-Resistive | 30 A |
Action | Non-Reversing |
Number of Poles | 2 |
Coil Volts | 24V AC |
Reversing | No |
HP @ 1 Phase - 120V | 1 hp |
HP @ 1 Phase - 230V | 2 |
Height | 2.64 in |
HP @ 1 Phase - 240V | 2 hp |
Width | 2.17 in |
Depth | 3.41 in |
Enclosure NEMA Rating | No Enclosure |
Standards | CE, cRUus |
Enclosure Type | Open |
Hz | 50/60 |
Includes | Not Applicable |
Series | Compact |
Phase | Single |
Fluorescent Lighting Current Rating | Not Applicable |
Coil Voltage | 24V AC |
Horsepower @ Three Phase - 480V AC | Not Rated |
NEMA Enclosure Material | Not Applicable |
Terminal Connection Type | Screw Terminals |
Horsepower @ Single Phase - 120V AC | 2 hp |
Minimum Operating Temperature | -40 Degrees F |
Status Indicator | Mechanical Flag |
Response Time | 20 msec |
Mounting Hole Distance - Height | 1.63 in |
Overall Height | 2.32 in |
Electrical Operating Durability | 200,000 |
Reversing Capability | Non-Reversing |
Frequency | 50/60 Hz |
Mounting Style | Through Panel |
Includes Shunt | Not Applicable |
Horsepower @ Three Phase - 600V AC | Not Rated |
Frame Size | Not Applicable |
Overall Width | 1.97 in |
Maximum Operating Temperature | 158 Degrees F |
Mounting Hole Diameter | Not Applicable |
Full Load Current - Resistive | 30 A |
Contactor Style | HVACR Definite Purpose Contactor |
Resistance Properties | Not Applicable |
Overall Depth | 3.19 in |
NEMA Enclosure Rating | No Enclosure |
Full Load Current - Inductive | 20 A |
Number of Normally Open Main Contacts | 2 |
IP Rating | Not Applicable |
Number of Normally Closed Main Contacts | 0 |
Number of Terminals | 6 |
LED Lighting Current Rating | Not Applicable |
Mechanical Operating Durability | 500,000 |
Input Control Type | Not Applicable |
Locked Rotor Load | 100 A @ 480V AC, 120 A @ 240/277V AC, 80 A @ 600V AC |
Horsepower @ Single Phase - 240V AC | 3 hp |
Auxiliary Contact Module Capacity | Not Applicable |
Horsepower @ Three Phase - 240V AC | Not Rated |
Tungsten Lighting Current Rating | Not Applicable |
Contact Material | Silver Cadmium Oxide |
Maximum Voltage Rating | 600V AC |
Mounting Hole Distance - Width | 1.61 in |
Horsepower @ Three Phase - 208V AC | Not Rated |
Mounting Postion | Horizontal, Vertical |
Country of Origin (subject to change) | China |
Package Quantity | 1 |
24VAC Non-Reversing Definite Purpose Contactor 2P 20A, DAYTON, Mfr# 6GNZ1
$22,85
-3% / ea
with subscription
Free shipping will be applied on orders over $50
Definite Purpose Magnetic Contactor, LED Lighting Current Rating Not Applicable, Coil Voltage 24V AC, Number of Poles 2, NEMA Enclosure Rating No Enclosure, Tungsten Lighting Current Rating Not Applicable, Fluorescent Lighting Current Rating Not Applicable, Reversing Capability Non-Reversing, Frame Size Not Applicable, Horsepower @ Single Phase - 240V AC 3 hp, Horsepower @ Single Phase - 120V AC 2 hp, Full Load Current - Resistive 30 A, Full Load Current - Inductive 20 A
9999 in stock
Must order in multiples of 1
Subtotal:
$22.85
You must be logged in to post a review.