Basic DC Accuracy
0.025% +2 Digits
Special Features
Low Pass Filter for Accurate Voltage and Frequency Measurements, Zoom on Trend Provides Unprecedented Ability to View and Analyze Trend, Capture Data
Calibration Certificate Included
No
Instrument Frequency Counter Range
99.99 Hz to 999.99 kHz
NIST Certification By
Not Certified
Includes
Alligator Clips, Current Clamp, Test Lead Set
Safety Rating
CAT III 1000V; CAT I 600V
Manufacturers Warranty Length
1 yr
Calibration Certificate
Not Included
Instrument Safety Rating
CAT IV 600V
Capacitance Range
1 nF to 1000 nF
Temp. Range
-128 Degrees F to 732 Degrees F (-200 Degrees C to 1350 Degrees C)
Minimum/Maximum Memory
Yes
Minimum DC Current Measurement
0 mA
Resistance Measurement Accuracy
+/-0.05%
AC Response Calculation
TRMS
Capacitance Measurement Accuracy
1.00 %
Maximum Resistance Measurement
500 megaohm
Minimum DC Voltage Measurement
0 V
Minimum Storage Temperature
-40 Degrees F
Maximum AC Current Measurement
400 A
Additional Components
Current Clamp Probe
Features
Bluetooth-Compatible ; Data Logging
Basic DC Voltage Accuracy
+/-0.025% + 2 Digits
Maximum Capacitance Measurement
1,000 nF
Parameters Measured
AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K)
AC Current Measurement Resolution
500 uA
Minimum AC Current Measurement
0 uA
Minimum Temperature Measurement
-128 Degrees F
Frequency Measurement Resolution
99.999 Hz
Basic AC Current Accuracy
+/-0.6%
True RMS Bandwidth
100 kHz
Computer Interface Connection Type
USB
Maximum AC Voltage Measurement
1,000 V
Multimeter Features
Bluetooth-Compatible, Data Logging
Resistance Measurement Resolution
50 ohm
Min-Max-Avg Button Included
Yes
Basic DC Current Accuracy
+/-0.05%
DC Current Measurement Resolution
500 uA
Maximum Operating Temperature
131 Degrees F
Maximum DC Current Measurement
400 A
Current Leakage Testing
No
Multiple On-Screen Displays
Yes
Maximum Storage Temperature
140 Degrees F
Minimum Frequency Measurement
99.99 Hz
Basic AC Voltage Accuracy
+/-0.4%
Minimum Capacitance Measurement
1 nF
Temperature Measurement Accuracy
1.00 %
DC Voltage Measurement Resolution
50 V
Battery Chemistry
Alkaline
AC Voltage Measurement Resolution
50 V
Maximum DC Voltage Measurement
1,000 V
Maximum Temperature Measurement
732 Degrees F
Maximum Frequency Measurement
999.99 kHz
Frequency Measurement Accuracy
0.005 %
Capacitance Measurement Resolution
1 nF
NIST Certification By Manufacturer
Not Certified
Minimum Operating Temperature
-4 Degrees F
Minimum AC Voltage Measurement
0 V
Country of Origin (subject to change)
United States