Promotion Restriction
Not eligible for promotion
Multimeter Style
Full Size - Basic Features
Basic DC Accuracy
+/-0.05% of Reading +2 Digits
Instrument Safety Rating
CAT III 600V
Instrument Frequency Counter Range
10 Hz to 50 kHz
Temp. Range
-40 Degrees to 752 Degrees F
Manufacturers Warranty Length
5 yr
Capacitance Range
10 pF to 1000 uF
Series
MILWAUKEE (R) 2216-20
Includes
(1) Electrical Test Lead Set, (2) AA Batteries
Display
Backlit Black On White LCD
Calibration Certificate Included
No
Special Features
Auto Range to MV, Capacitance to 1000 ¿f, CAT III 600V for Increased Safety, Current Measurement to 10A AC/DC, Frequency Measurements from 10Hz to 50KHz, Resistance Range from 600 Ohm to 40 Mohm, Rugged Over-Molding Increases Durability and User Grip, True-RMS for Accurate Measurement in All Applications, Wide Voltage Range to 600 AC/Dc Volts
Standards
C1, CE, cULus, EMC EN61326-1, EN61010-031 (Probes), EN61010-1, IEC/EN61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, UL 61010-031 (Probes), UL 61010-1
Calibration Certificate
No
Parameters Measured
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance
AC Response Calculation
TRMS
AC Voltage Measurement Resolution
Not Applicable
Minimum Capacitance Measurement
10 pF
Minimum DC Current Measurement
0 A
Maximum Capacitance Measurement
1,000 uF
Maximum AC Current Measurement
10 A
Maximum DC Current Measurement
10 A
Maximum AC Voltage Measurement
600 V
Minimum/Maximum Memory
Yes
Minimum AC Current Measurement
0 A
Minimum Temperature Measurement
-40 Degrees F
Maximum Resistance Measurement
40 megaohm
Maximum Temperature Measurement
752 Degrees F
Resistance Measurement Accuracy
+/-2%
Minimum Storage Temperature
-40 Degrees F
Basic AC Current Accuracy
+/-1.5%
AC Current Measurement Resolution
Not Applicable
Maximum Storage Temperature
140 Degrees F
Temperature Measurement Accuracy
Not Applicable
Multimeter Features
Data Logging, Dustproof
Capacitance Measurement Resolution
Not Applicable
Maximum DC Voltage Measurement
600 V
Frequency Measurement Accuracy
+/-0.10%
Resistance Measurement Resolution
Not Applicable
Basic AC Voltage Accuracy
+/-2%
DC Current Measurement Resolution
Not Applicable
Basic DC Current Accuracy
+/-1%
Capacitance Measurement Accuracy
+/-1.90%
Computer Interface Connection Type
None
Basic DC Voltage Accuracy
+/-0.05% + 2 Digits
Maximum Frequency Measurement
50 kHz
Minimum AC Voltage Measurement
6 V
Minimum Frequency Measurement
2 Hz
Maximum Operating Temperature
122 Degrees F
Minimum DC Voltage Measurement
0 V
Minimum Resistance Measurement
600 ohm
DC Voltage Measurement Resolution
Not Applicable
Battery Chemistry
Alkaline
Minimum Operating Temperature
14 Degrees F
Frequency Measurement Resolution
Not Applicable
Min-Max-Avg Button Included
Yes
Current Leakage Testing
No
Country of Origin (subject to change)
Taiwan, Province of China