Promotion Restriction
Not eligible for promotion
Includes
(4) TRM50 Cable Terminators, (4) VPS410-II Probes, AC Power Adapter, Carrying Case, DWA-131 Wi-Fi Dongle, Hand Strap, Hanging Strap, Power Cord, USB Cable
Persistence
Off, Short, Medium, Long, Infinite and Envelope Mode
Manufacturers Warranty Length
1 yr (Battery and Accessories), 3 yr (Main Instrument)
Waveform / Measurement Stored
Two Multiple Input ScopeRecord Waveforms Can Be Saved Internally for Later Recall And Analysis
Real Time Clock
Yes, Provides Date and Time Stamp Information for ScopeRecord, for 100 Screen Replay Sequences and for TrendPlot Recordings
Features
10,000 Points per Trace Waveform Capture (Scope Mode), 4 Independently Floating Isolated Inputs Up to 1000V, 999 Count DMM (2-ch Models: Insulated 5,000 Counts DMM Built-In), Automatic Capture and Replay of 100 Screens, Connect-and-View(TM) Triggering, Frequency Spectrum Analysis Using FFT-Analysis, ScopeRecord(TM) Roll Mode, TrendPlot(TM) Paperless Recorder Mode with Deep Memory, Up to 5 GS/s High-Speed Sampling
Safety Rating
CAT III 1000V/CAT IV 600V
Calibration Certificate
Yes
Max./Min. Sweep Speed
10 nsec/div to 4 sec/div
Input Sensitivity
With 10:1 Probe, 20 mV to 1000 V/div_x000B; With 100:1 Probe, 200 mV to 10 kV/div _x000B; Direct (1:1), 2 mV to 100 V/div
Battery Type
Rechargeable Li-Ion
Max. Record Length
10k/ Channel
AC Voltage Measurement - Minimum
500 mV AC
AC Current Measurement - Maximum
Not Applicable
Input Sensitivity - Minimum
100 V/div
CAT Safety Rating
CAT III 1000V, CAT IV 600V
Includes Batteries
Batteries Included
Time Base - Maximum
4 sec/div
Digital Display Screen Type
LCD
Calibration Certificate Type
Not Certified
Time Base - Minimum
10 nsec/div
DC Voltage Measurement - Maximum
1,100 V DC
Input Sensitivity - Maximum
100 V/div
Capacitance Measurement - Maximum
Not Applicable
Standards
EN 61010-1, IEC 61010-2-030: CAT IV 600V/CAT III 1000V
AC Voltage Measurement - Maximum
1,100 V AC
AC Voltage Measurement Resolution
100 mV
Basic AC Voltage Accuracy
+/-(1% +10 Counts)
Display Screen Width
3.5 in
Basic DC Voltage Accuracy
+/-(0.50% +6 Counts)
Display Screen Length
5.2 in
Battery Chemistry
Lithium Ion
AC Current Measurement - Minimum
Not Applicable
AC Magnitude Calculation
True RMS
DC Current Measurement - Maximum
Not Applicable
DC Voltage Measurement - Minimum
500 mV DC
Memory Depth
30,000 Data Points Per Channel
DC Current Measurement - Minimum
Not Applicable
Capacitance Measurement - Minimum
Not Applicable
Channel Source Isolation
Fully Isolated
Country of Origin (subject to change)
Romania