Promotion Restriction | Not eligible for promotion |
Item | Drywell |
Accuracy | +/-0.2 Degrees C Full Range |
Thermocouple Type | C, E, J, K, L, M, N, R, S, T, U |
Loop Supply Voltage | 24V DC |
RTD Type | 4 Wire, 3 Wire, 2 Wire |
RTD Temperature Range | -139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C) |
Thermocouple Temperature Range | -139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C) |
Calibration Certificate | yes |
Includes | 6 ft Main Power Cord, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap |
Display | LCD |
Agency Compliance | EU Directives, CSA, Australian EMC Requirements |
Interface | RS-232, USB Cable |
Max. Loop Current | 4 to 20mA |
Power Source | Plug-In |
Standards | IEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic |
RTD Temperature Range F | -139 Degrees to 284 Degrees F |
Reference Junction Temperature Characteristics | +/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C |
Overall Height | 18.81 in |
Display Temperature Accuracy | +/-0.2 Degrees C |
Stability | +/-0.015 Degrees C |
Well Depth | 6.31 in |
Sensor Type | RTD, Thermocouple |
Typical Uniformity | +/-0.05 Degrees C |
Power Source Details | 100 to 115V, 200 to 230V |
Well Size | 1 3/16 in Dia x 6 5/16 D Well |
Overall Width | 8 in |
Typical Cooling Time | 80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C), 60 min (140 Degrees to 23 Degrees C) |
Thermocouple Temperature Range F | -139 Degrees to 284 Degrees F |
Display Resolution | 0.01 Degrees |
With Process Connections | Yes |
Application | Blood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves) |
Stabilization Time | 15 min |
Temperature Range | -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C |
For RTD Type | 2-Wire, 3-Wire, 4-Wire, Ni-120, PT-100 (385), PT-100 (3926), PT-100 (JIS) |
For Thermocouple Type | Type C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U |
Calibrator Weight | 35 lb |
Thermocouple Temperature Range C | -95 Degrees to 140 Degrees C |
RTD Temperature Range C | -95 Degrees to 140 Degrees C |
Thermocouple Temperature Accuracy Characteristics | Type C: +/-1.00 Degrees C at 140 Degrees C, Type E: +/-0.60 Degrees C at 140 Degrees C, Type J: +/-0.70 Degrees C at 140 Degrees C, Type K: +/-0.75 Degrees C at 140 Degrees C, Type L: +/-0.65 Degrees C at 140 Degrees C, Type M: +/-0.65 Degrees C at 140 Degrees C, Type N: +/-0.75 Degrees C at 140 Degrees C, Type R: +/-1.60 Degrees C at 140 Degrees C, Type S: +/-1.60 Degrees C at 140 Degrees C, Type T: +/-0.60 Degrees C at 140 Degrees C, Type U: +/-0.70 Degrees C at 140 Degrees C |
Calibrator Accuracy | +/-0.2 Degrees C |
Thermocouple mV Characteristics | 0.025% + 0.01 mV at -10 to 75 mV |
Reference Input Temperature Characteristics | +/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C |
Overall Depth | 14.91 in |
Overall Dimensions | 18 13/16 in H x 8 in W x 14 29/32 in D |
Typical Heating Time | 40 min (-95 Degrees to 140 Degrees C) |
Probe Connection Types | (1) 4-Terminal RTD Input, (1) Miniature connectors (ASTM E1684) |
Resistance Sensing Current Characteristics | 0.02% at 0.002 mA, Cal 4-22 mA, Spec 4-24 mA |
Current mA Characteristics | 0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range |
Reference Input Resistance Characteristics | +/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm) |
Calibrator Type | Field Metrology Well |
For Stem Diameter | (2) 3 mm, (2) 4 mm, (2), 6 mm |
Well Diameter | 1.19 in |
Brand and Series | Fluke 9190A |
Number of Set Points | Variable |
Set Point Style | Adjustable |
Single Well/Dual Well | Single Well |
4-Wire Device Resistance Characteristics | Range: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms) |
Temperature Accuracy | +/-0.2 Degrees C |
Country of Origin (subject to change) | United States |
Package Quantity | 1 |
Drywell, Temperature Calibrator, FLUKE, Mfr# 9190A-DW-P-156
$24369,00
Free shipping will be applied on orders over $50
Drywell, Field Metrology Well, Fluke 9190A, -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C, Interface RS-232, USB Cable, Number of Set Points Variable, 18 13/16 in H x 8 in W x 14 29/32 in D
9999 in stock
Must order in multiples of 1
Subtotal:
$24369
You must be logged in to post a review.