Drywell, Field Metrology Well, Fluke 9190A, -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C, Interface RS-232, USB Cable, Number of Set Points Variable, 18 13/16 in H x 8 in W x 14 29/32 in D

9999 in stock

Must order in multiples of 1
Subtotal:
$24369
Final shipping and tax calculated in checkout
Brand Name: FLUKE
Mfr #: 9190A-DW-P-156
Availability: Ships in 10 days
SKU: GRG8016687 Category:
Promotion RestrictionNot eligible for promotion
ItemDrywell
Accuracy+/-0.2 Degrees C Full Range
Thermocouple TypeC, E, J, K, L, M, N, R, S, T, U
Loop Supply Voltage24V DC
RTD Type4 Wire, 3 Wire, 2 Wire
RTD Temperature Range-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Thermocouple Temperature Range-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Calibration Certificateyes
Includes6 ft Main Power Cord, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
DisplayLCD
Agency ComplianceEU Directives, CSA, Australian EMC Requirements
InterfaceRS-232, USB Cable
Max. Loop Current4 to 20mA
Power SourcePlug-In
StandardsIEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic
RTD Temperature Range F-139 Degrees to 284 Degrees F
Reference Junction Temperature Characteristics+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Overall Height18.81 in
Display Temperature Accuracy+/-0.2 Degrees C
Stability+/-0.015 Degrees C
Well Depth6.31 in
Sensor TypeRTD, Thermocouple
Typical Uniformity+/-0.05 Degrees C
Power Source Details100 to 115V, 200 to 230V
Well Size1 3/16 in Dia x 6 5/16 D Well
Overall Width8 in
Typical Cooling Time80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C), 60 min (140 Degrees to 23 Degrees C)
Thermocouple Temperature Range F-139 Degrees to 284 Degrees F
Display Resolution0.01 Degrees
With Process ConnectionsYes
ApplicationBlood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves)
Stabilization Time15 min
Temperature Range-139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C
For RTD Type2-Wire, 3-Wire, 4-Wire, Ni-120, PT-100 (385), PT-100 (3926), PT-100 (JIS)
For Thermocouple TypeType C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
Calibrator Weight35 lb
Thermocouple Temperature Range C-95 Degrees to 140 Degrees C
RTD Temperature Range C-95 Degrees to 140 Degrees C
Thermocouple Temperature Accuracy CharacteristicsType C: +/-1.00 Degrees C at 140 Degrees C, Type E: +/-0.60 Degrees C at 140 Degrees C, Type J: +/-0.70 Degrees C at 140 Degrees C, Type K: +/-0.75 Degrees C at 140 Degrees C, Type L: +/-0.65 Degrees C at 140 Degrees C, Type M: +/-0.65 Degrees C at 140 Degrees C, Type N: +/-0.75 Degrees C at 140 Degrees C, Type R: +/-1.60 Degrees C at 140 Degrees C, Type S: +/-1.60 Degrees C at 140 Degrees C, Type T: +/-0.60 Degrees C at 140 Degrees C, Type U: +/-0.70 Degrees C at 140 Degrees C
Calibrator Accuracy+/-0.2 Degrees C
Thermocouple mV Characteristics0.025% + 0.01 mV at -10 to 75 mV
Reference Input Temperature Characteristics+/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C
Overall Depth14.91 in
Overall Dimensions18 13/16 in H x 8 in W x 14 29/32 in D
Typical Heating Time40 min (-95 Degrees to 140 Degrees C)
Probe Connection Types(1) 4-Terminal RTD Input, (1) Miniature connectors (ASTM E1684)
Resistance Sensing Current Characteristics0.02% at 0.002 mA, Cal 4-22 mA, Spec 4-24 mA
Current mA Characteristics0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range
Reference Input Resistance Characteristics+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Calibrator TypeField Metrology Well
For Stem Diameter(2) 3 mm, (2) 4 mm, (2), 6 mm
Well Diameter1.19 in
Brand and SeriesFluke 9190A
Number of Set PointsVariable
Set Point StyleAdjustable
Single Well/Dual WellSingle Well
4-Wire Device Resistance CharacteristicsRange: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Temperature Accuracy+/-0.2 Degrees C
Country of Origin (subject to change)United States
Package Quantity1
TAGS:
#Drywell
#Temperature Calibrator
#FLUKE
#Mfr 9190A-DW-P-156
#FLUKE
#GRG8016687
#mfr:9190A-DW-P-156
#part number:9190A-DW-P-156
#pn:9190A-DW-P-156
#part code:9190A-DW-P-156
#item number:9190A-DW-P-156
#product code:9190A-DW-P-156
#manufacturer number:9190A-DW-P-156
#manufacturers part number:9190A-DW-P-156
#mfn:9190A-DW-P-156

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!