Drywell, Temperature, FLUKE, Mfr# 9143-E-P-156

$8650,00
Free shipping will be applied on orders over $50

Drywell, Field Metrology Well, Fluke 9143, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D

9999 in stock

Must order in multiples of 1
Subtotal:
$8650
Final shipping and tax calculated in checkout
Brand Name: FLUKE
Mfr #: 9143-E-P-156
Availability: Ships in 10 days
SKU: GRG8174171 Category:
Promotion RestrictionNot eligible for promotion
ItemDrywell
Accuracy+/-0.03 Degrees C
Thermocouple TypeC, E, J, K, L, M, N, R, S, T, U
Loop Supply Voltage24V DC
RTD TypeNI-120, 385, 3892, JIS
RTD Temperature Range-196 to 660 Degrees C
Thermocouple Temperature Range0 to 1480 Degrees C (type S)
Includes9143 Field Metrology Well, Insert for Configuration Ordered, Power Cord, RS-232 Cable, User Guide, Technical Manual CD, Report of Calibration, Calibration Label, 6-pin DIN Connector, Test Lead Kit, Clamp-on ferrites (3), Tongs (insert removal tool), 9930 Interface-it Software and User's Guide
InterfaceRS-232
DisplayLCD
Agency ComplianceCE, CSA, C-TICK, ROHS, WEEE
Max. Loop Current24 mA
Calibration CertificateNVLAP accredited
StandardsNVLAP Accredited
For Thermocouple TypeType C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
RTD Temperature Range C-196 Degrees to 660 Degrees C
Overall Height11.41 in
Probe Connection Types(1) 4-Terminal RTD Input, (1) Small Connectors TC
Calibrator Weight16 lb
Reference Input Temperature Characteristics+/-0.010 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 150 Degrees C, +/-0.030 Degrees C at 200 Degrees C, +/-0.040 Degrees C at 350 Degrees C, +/-0.050 Degrees C at 420 Degrees C, +/-0.070 Degrees C at 660 Degrees C
For RTD Type4-Wire, Ni-120
Calibrator ApplicationIndustrial Process Environment
Brand and SeriesFluke 9143
Resistance Sensing Current Characteristics0.02% at 2 mV, Cal 4-22 mA, Spec 4-24 mA
Reference Junction Temperature Characteristics+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Calibrator TypeField Metrology Well
Includes NIST-Traceable CertificateNo
For Stem Diameter(2) 3 mm, (2) 4 mm, (2) 6 mm
Current mA Characteristics0.02% + 2 mV Accuracy/4 to 22 mA, 4 to 24 mA Range
Overall Width7.31 in
Thermocouple Temperature Range C0 Degrees to 1,480 Degrees C
Reference Input Resistance Characteristics+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Typical Heating Time5 min (33 Degrees to 350 Degrees C)
Display Resolution0.01 Degrees
Well Size5 29/32 D Well
Overall Depth11.61 in
Display Temperature Accuracy+/-0.2 Degrees C
Typical Cooling Time32 min (350 Degrees to 33 Degrees C), 14 min (350 Degrees to 100 Degrees C)
With Process ConnectionsYes
Calibrator Accuracy+/-0.2 Degrees C (Display - Full Range)
Calibration DetailsNVLAP Accredited Calibration Included
Thermocouple mV Characteristics0.025% + 0.01 mV at -10 to 75 mV
Sensor TypeRTD, Thermocouple
Thermocouple Temperature Accuracy CharacteristicsType C: +/-1.1 Degrees C at 660 Degrees C, Type E: +/-0.7 Degrees C at 660 Degrees C, Type J: +/-0.7 Degrees C at 660 Degrees C, Type K: +/-0.8 Degrees C at 660 Degrees C, Type L: +/-0.7 Degrees C at 660 Degrees C, Type M: +/-1.4 Degrees C at 660 Degrees C, Type N: +/-0.9 Degrees C at 660 Degrees C, Type R: +/-1.4 Degrees C at 660 Degrees C, Type S: +/-1.5 Degrees C at 660 Degrees C, Type T: +/-0.8 Degrees C at 400 Degrees C, Type U: +/-0.75 Degrees C at 600 Degrees C
Overall Dimensions11 13/32 in H x 7 5/16 in W x 11 39/64 in D
Power Source Details100 to 115V, 230V
Temperature Range-196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C
Stability+/-0.02 Degrees C at 200 Degrees C, +/-0.02 Degrees C at 33 Degrees C, +/-0.03 Degrees C at 350 Degrees C
ApplicationField Testing
Typical Uniformity+/-0.04 Degrees C at 33 Degrees C, +/-0.1 Degrees C at 200 Degrees C, +/-0.2 Degrees C at 350 Degrees C, +/-0.01 Degrees C at 33 Degrees C, +/-0.015 Degrees C at 200 Degrees C, +/-0.02 Degrees C at 350 Degrees C
Well Depth5.91 in
4-Wire Device Resistance CharacteristicsRange: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Set Point StyleAdjustable
Single Well/Dual WellSingle Well
Number of Set PointsVariable
Temperature Accuracy+/-0.03 Degrees C
Country of Origin (subject to change)United States
Package Quantity1
TAGS:
#Drywell
#Temperature
#FLUKE
#Mfr 9143-E-P-156
#FLUKE
#GRG8174171
#mfr:9143-E-P-156
#part number:9143-E-P-156
#pn:9143-E-P-156
#part code:9143-E-P-156
#item number:9143-E-P-156
#product code:9143-E-P-156
#manufacturer number:9143-E-P-156
#manufacturers part number:9143-E-P-156
#mfn:9143-E-P-156

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!