Drywell, Temperature, FLUKE, Mfr# 9144-C-P-156

$9131,00
Free shipping will be applied on orders over $50

Drywell, Field Metrology Well, Fluke 9144, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D

0 in stock

Must order in multiples of 1
Subtotal:
$9131
Final shipping and tax calculated in checkout
Brand Name: FLUKE
Mfr #: 9144-C-P-156
Availability: Ships in 10 days
SKU: GRG7837085 Category:
Promotion RestrictionNot eligible for promotion
ItemDrywell
Accuracy+/-0.05 Degrees C
Thermocouple TypeC, E, J, K, L, M, N, R, S, T, U
Loop Supply Voltage24V DC
RTD TypeNI-120, 385, 3892, JIS
RTD Temperature Range-196 to 660 Degrees C
Thermocouple Temperature Range0 to 1480 Degrees C (type S)
Agency ComplianceCE, CSA, C-TICK, ROHS, WEEE
Calibration CertificateNVLAP accredited
Max. Loop Current24 mA
Includes9144 Field Metrology Well, Insert for Configuration Ordered, Power Cord, RS-232 Cable, User Guide, Technical Manual CD, Report of Calibration, Calibration Label, 6-pin DIN Connector, Test Lead Kit, Clamp-on ferrites (3), Tongs (insert removal tool), 9930 Interface-it Software and User's Guide
InterfaceRS-232
DisplayLCD
StandardsNVLAP Accredited
Typical Uniformity+/-0.05 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C, +/-0.02 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 420 Degrees C, +/-0.10 Degrees C at 660 Degrees C
Calibrator ApplicationIndustrial Process Environment
Resistance Sensing Current Characteristics0.02% at 2 mV, Cal 4-22 mA, Spec 4-24 mA
Overall Width7.31 in
Includes NIST-Traceable CertificateNo
Overall Dimensions11 13/32 in H x 7 5/16 in W x 11 39/64 in D
Calibrator TypeField Metrology Well
RTD Temperature Range C-196 Degrees to 660 Degrees C
Display Temperature Accuracy+/-0.35 Degrees C at 420 Degrees C, +/-0.35 Degrees C at 50 Degrees C, +/-0.5 Degrees C at 660 Degrees C
Typical Cooling Time25 min (660 Degrees to 100 Degrees C), 35 min (660 Degrees to 50 Degrees C)
Sensor TypeRTD, Thermocouple
Stability+/-0.03 Degrees C at 50 Degrees C, +/-0.04 Degrees C at 420 Degrees C, +/-0.05 Degrees C at 660 Degrees C
Thermocouple Temperature Range C0 Degrees to 1,480 Degrees C
Calibrator Accuracy+/-0.35 Degrees C at 420 Degrees C, +/-0.35 Degrees C at 50 Degrees C, +/-0.5 Degrees C at 660 Degrees C
Thermocouple mV Characteristics0.025% + 0.01 mV at -10 to 75 mV
With Process ConnectionsYes
Brand and SeriesFluke 9144
Well Size5 29/32 D Well
For Thermocouple TypeType C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
Calibrator Weight17 lb
Display Resolution0.01 Degrees
Probe Connection Types(1) 4-Terminal RTD Input, (1) Small Connectors TC
Reference Junction Temperature Characteristics+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Current mA Characteristics0.02% + 2 mV Accuracy/4 to 22 mA, 4 to 24 mA Range
Well Depth5.91 in
Overall Height11.41 in
For RTD Type4-Wire, Ni-120
Temperature Range-196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C
ApplicationField Testing
Calibration DetailsNVLAP Accredited Calibration Included
Overall Depth11.61 in
For Stem Diameter(4) 1/4 in
Typical Heating Time15 min (50 Degrees to 660 Degrees C)
Thermocouple Temperature Accuracy CharacteristicsType C: +/-1.1 Degrees C at 660 Degrees C, Type E: +/-0.7 Degrees C at 660 Degrees C, Type J: +/-0.7 Degrees C at 660 Degrees C, Type K: +/-0.8 Degrees C at 660 Degrees C, Type L: +/-0.7 Degrees C at 660 Degrees C, Type M: +/-1.4 Degrees C at 660 Degrees C, Type N: +/-0.9 Degrees C at 660 Degrees C, Type R: +/-1.4 Degrees C at 660 Degrees C, Type S: +/-1.5 Degrees C at 660 Degrees C, Type T: +/-0.8 Degrees C at 400 Degrees C, Type U: +/-0.75 Degrees C at 600 Degrees C
Power Source Details100 to 115V, 230V
Reference Input Temperature Characteristics+/-0.010 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 150 Degrees C, +/-0.030 Degrees C at 200 Degrees C, +/-0.040 Degrees C at 350 Degrees C, +/-0.050 Degrees C at 420 Degrees C, +/-0.070 Degrees C at 660 Degrees C
Reference Input Resistance Characteristics+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Single Well/Dual WellSingle Well
4-Wire Device Resistance CharacteristicsRange: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Number of Set PointsVariable
Set Point StyleAdjustable
Temperature Accuracy+/-0.05 Degrees C
Country of Origin (subject to change)United States
Package Quantity1
TAGS:
#Drywell
#Temperature
#FLUKE
#Mfr 9144-C-P-156
#FLUKE
#GRG7837085
#mfr:9144-C-P-156
#part number:9144-C-P-156
#pn:9144-C-P-156
#part code:9144-C-P-156
#item number:9144-C-P-156
#product code:9144-C-P-156
#manufacturer number:9144-C-P-156
#manufacturers part number:9144-C-P-156
#mfn:9144-C-P-156

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!