Drywell, Temperature, FLUKE, Mfr# 9144-D-P-156

$9131,00

Free shipping will be applied on orders over $50

Drywell, Field Metrology Well, Fluke 9144, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D

9999 in stock

Must order in multiples of 1
Subtotal:
$9131
Final shipping and tax calculated in checkout
Brand Name: FLUKE
Mfr #: 9144-D-P-156
Availability: Ships in 10 days
SKU: GRG8046193 Category:
Promotion RestrictionNot eligible for promotion
ItemDrywell
Accuracy+/-0.05 Degrees C
Thermocouple TypeC, E, J, K, L, M, N, R, S, T, U
Loop Supply Voltage24V DC
RTD TypeNI-120, 385, 3892, JIS
RTD Temperature Range-196 to 660 Degrees C
Thermocouple Temperature Range0 to 1480 Degrees C (type S)
Max. Loop Current24 mA
Includes9144 Field Metrology Well, Insert for Configuration Ordered, Power Cord, RS-232 Cable, User Guide, Technical Manual CD, Report of Calibration, Calibration Label, 6-pin DIN Connector, Test Lead Kit, Clamp-on ferrites (3), Tongs (insert removal tool), 9930 Interface-it Software and User's Guide
Agency ComplianceCE, CSA, C-TICK, ROHS, WEEE
Calibration CertificateNVLAP accredited
DisplayLCD
InterfaceRS-232
StandardsNVLAP Accredited
Brand and SeriesFluke 9144
Typical Heating Time15 min (50 Degrees to 660 Degrees C)
Stability+/-0.03 Degrees C at 50 Degrees C, +/-0.04 Degrees C at 420 Degrees C, +/-0.05 Degrees C at 660 Degrees C
Power Source Details100 to 115V, 230V
Display Temperature Accuracy+/-0.35 Degrees C at 420 Degrees C, +/-0.35 Degrees C at 50 Degrees C, +/-0.5 Degrees C at 660 Degrees C
Reference Input Temperature Characteristics+/-0.010 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 150 Degrees C, +/-0.030 Degrees C at 200 Degrees C, +/-0.040 Degrees C at 350 Degrees C, +/-0.050 Degrees C at 420 Degrees C, +/-0.070 Degrees C at 660 Degrees C
With Process ConnectionsYes
Calibrator ApplicationIndustrial Process Environment
RTD Temperature Range C-196 Degrees to 660 Degrees C
For RTD Type4-Wire, Ni-120
Includes NIST-Traceable CertificateNo
Overall Dimensions11 13/32 in H x 7 5/16 in W x 11 39/64 in D
Well Size5 29/32 D Well
Calibration DetailsNVLAP Accredited Calibration Included
Probe Connection Types(1) 4-Terminal RTD Input, (1) Small Connectors TC
Thermocouple mV Characteristics0.025% + 0.01 mV at -10 to 75 mV
Overall Height11.41 in
Calibrator Accuracy+/-0.35 Degrees C at 420 Degrees C, +/-0.35 Degrees C at 50 Degrees C, +/-0.5 Degrees C at 660 Degrees C
Resistance Sensing Current Characteristics0.02% at 2 mV, Cal 4-22 mA, Spec 4-24 mA
ApplicationField Testing
Reference Input Resistance Characteristics+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Calibrator TypeField Metrology Well
For Thermocouple TypeType C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
Well Depth5.91 in
Current mA Characteristics0.02% + 2 mV Accuracy/4 to 22 mA, 4 to 24 mA Range
Calibrator Weight17 lb
Typical Cooling Time25 min (660 Degrees to 100 Degrees C), 35 min (660 Degrees to 50 Degrees C)
Reference Junction Temperature Characteristics+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Typical Uniformity+/-0.05 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C, +/-0.02 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 420 Degrees C, +/-0.10 Degrees C at 660 Degrees C
Thermocouple Temperature Accuracy CharacteristicsType C: +/-1.1 Degrees C at 660 Degrees C, Type E: +/-0.7 Degrees C at 660 Degrees C, Type J: +/-0.7 Degrees C at 660 Degrees C, Type K: +/-0.8 Degrees C at 660 Degrees C, Type L: +/-0.7 Degrees C at 660 Degrees C, Type M: +/-1.4 Degrees C at 660 Degrees C, Type N: +/-0.9 Degrees C at 660 Degrees C, Type R: +/-1.4 Degrees C at 660 Degrees C, Type S: +/-1.5 Degrees C at 660 Degrees C, Type T: +/-0.8 Degrees C at 400 Degrees C, Type U: +/-0.75 Degrees C at 600 Degrees C
Display Resolution0.01 Degrees
Overall Width7.31 in
Thermocouple Temperature Range C0 Degrees to 1,480 Degrees C
Overall Depth11.61 in
For Stem Diameter(2) 3 mm, (2) 4 mm, (2) 6 mm
Sensor TypeRTD, Thermocouple
Temperature Range-196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C
4-Wire Device Resistance CharacteristicsRange: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Number of Set PointsVariable
Set Point StyleAdjustable
Single Well/Dual WellSingle Well
Temperature Accuracy+/-0.05 Degrees C
Country of Origin (subject to change)United States
Package Quantity1
TAGS:
#Drywell
#Temperature
#FLUKE
#Mfr 9144-D-P-156
#FLUKE
#GRG8046193
#mfr:9144-D-P-156
#part number:9144-D-P-156
#pn:9144-D-P-156
#part code:9144-D-P-156
#item number:9144-D-P-156
#product code:9144-D-P-156
#manufacturer number:9144-D-P-156
#manufacturers part number:9144-D-P-156
#mfn:9144-D-P-156

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!