IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 18 A, Full Load Current - Resistive 18 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Easy, Number of Auxillary Contacts 1, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 3 hp

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: DPE18BL
Availability: Ships in 5 days
SKU: GRG403481106 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive18 A
Full Load Amps-Resistive18 A
Number of Poles3
Coil Volts24 V DC
ReversingNo
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 240V2 hp
HP @ 3 Phase - 208V3 hp
HP @ 3 Phase - 240V3 hp
HP @ 3 Phase - 480V7 1/2 hp
HP @ 3 Phase - 575V10 hp
Aux. Contact Configuration1NO
Enclosure NEMA Rating3R, 4
Hz50/60 Hz
Height3.03 in
Width1.77 in
StandardsCSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
Depth3.39 in
Frame / Series / Class / CodeTeSys
Special FeaturesOvervoltage Category III, Minimum Switching Voltage 17 V Signalling Circuit, Insulation Resistance 10 MOhm Signalling Circuit
Overall Height3.03 in
Overall Width1.77 in
IncludesNot Applicable
FeaturesWithout Built-In Suppressor Module
ApplicationMotor Control, Resistive Load
Non-Overlap Time1.5 ms
Net Weight0.325 kg
Switching Current5 mA (Signalling Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Signalling Circuit Frequency25 to 400 Hz
Environmental AttributesMercury Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Voltage690V AC, 300V DC
Impulse Withstand Voltage6 kV
Operating Time65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening)
Max. Temperature850°C
Thermal Amperage10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Watts Loss2 to 3W
Fuse Amps10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Rated Insulation Volts600/690V
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Working HeightUp to 6561.68 ft
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Operating Speed3600 cycles per hr
Electrical Durability1 Mcycles (18 A, AC-3, Less than 440 V), 0.6 Mcycles (25 A, AC-1, Less than 440 V)
Max. Operating Watts4 kW (at 220 to 230V AC 50/60 Hz), 7.5 kW (at 380 to 400V AC 50/60 Hz), 9 kW (at 415V AC 50/60 Hz), 9 kW (at 440V AC 50/60 Hz), 10 kW (at 500V AC 50/60 Hz), 10 kW (at 660 to 690V AC 50/60 Hz)
Control Circuit Voltage LimitsDrop-Out: 0.1 to 0.3 Uc (at 70°C), Operational: 0.8 to 1.25 Uc (at 60°C), 1 to 1.25 Uc (at 70°C)
Rated Breaking Capacity250 A @ 440V
Mounts OnPlate, Rail
Tightening Torque1.7 Nm
Impedance2.5 mOhm
Electrical ConnectionScrew Clamp Terminals
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Mechanical Durability10 Mcycles
Overvoltage CategoryCAT III
SeriesTeSys Easy
IP RatingIP20
Switching Voltage17 V (Signalling Circuit)
Horsepower @ Three Phase - 240V AC3 hp
Embedded Surge SuppressorNo
NEMA Enclosure RatingNo Enclosure
Horsepower @ Single Phase - 120V AC1/2 hp
Maximum Operating Temperature140 Degrees F
Auxiliary Contact Form1NO
Frequency50/60 Hz
Horsepower @ Three Phase - 600V AC10 hp
Includes Auxiliary ContactsYes
Horsepower @ Three Phase - 480V AC7 1/2 hp
Horsepower @ Single Phase - 240V AC2 hp
NEMA SizeNot Applicable
Number of Normally Open Main Contacts3
Coil Voltage24V DC
Reversing CapabilityNon-Reversing
Resistance PropertiesFire Resistant, Insulation Resistant
Maximum Voltage Rating690V AC
Overall Depth3.39 in
Number of Auxillary Contacts1
Contactor StyleIEC
Electrical Operating Durability1,000,000, 600,000
Full Load Current - Resistive18 A
Minimum Operating Temperature-40 Degrees F
Full Load Current - Inductive18 A
Mechanical Operating Durability10,000,000
Terminal Connection TypeScrew Clamp Terminals
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 208V AC3 hp
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#Easy TeSys
#3 Poles
#24 V DC
#18 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr DPE18BL
#SCHNEIDER ELECTRIC
#GRG403481106
#mfr:DPE18BL
#part number:DPE18BL
#pn:DPE18BL
#part code:DPE18BL
#item number:DPE18BL
#product code:DPE18BL
#manufacturer number:DPE18BL
#manufacturers part number:DPE18BL
#mfn:DPE18BL

Reviews

There are no reviews yet.

Add a review