IEC Magnetic Contactor, 3 Poles, 100 to 250 V AC/DC, 12 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D12KUE

$44,79

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 100-250V AC/DC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 25 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$44.79
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D12KUE
Availability: Ships in 5 days
SKU: GRG6555530 Category:
Full Load Amps-Inductive12 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive25 A
Number of Poles3
Coil Volts100 to 250 V AC/DC
ReversingNo
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 240V2 hp
Height3.03 in
HP @ 3 Phase - 208V3 hp
Width1.77 in
HP @ 3 Phase - 575V10 hp
Depth3.38 in
HP @ 3 Phase - 240V3 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V7 1/2 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
SeriesTeSys Deca
NEMA SizeNot Applicable
Auxiliary Contact Form1NO/1NC
Fuse Amps10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Rated Insulation Volts690V
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Watts Loss1.1W
Includes Protective CoverYes
Tightening Torque1.7 Nm
Operating Speed3600 cycles per hr
Rated Voltage690V AC
Max. Operating Watts3 kW (at 220 to 230V AC 50 Hz AC-3), 5.5 kW (at 380 to 400V AC 50 Hz AC-3), 5.5 kW (at 415V AC 50 Hz AC-3), 5.5 kW (at 440V AC 50 Hz AC-3), 7.5 kW (at 500V AC 50 Hz AC-3), 7.5 kW (at 660 to 690V AC 50 Hz AC-3), 3 kW (at 220 to 230V AC 50 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50 Hz AC-3e), 5.5 kW (at 415V AC 50 Hz AC-3e), 5.5 kW (at 440V AC 50 Hz AC-3e), 7.5 kW (at 500V AC 50 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50 Hz AC-3e)
Working HeightUp to 9842.52 ft
Fire RatingUL 94 V1
Impulse Withstand Voltage6 kV
Rated Breaking Capacity250 A @ 440V
Control Circuit Voltage LimitsDrop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC/DC: 0.85 to 1.1 Uc (at -40 to 60°C), 1 to 1.1 Uc (at 60 to 70°C)
Overvoltage CategoryCAT III
Switching Voltage17 V (Signalling Circuit)
Inrush VA25 VA
Mounts OnPlate, Rail
Electrical ConnectionScrew Clamp Terminals
Hold VA1.6 VA
Rated Short-Time Withstand Current100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit)
Net Weight0.373 kg
Thermal Amperage10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Operating Time45 to 55 ms (Closing), 20 to 90 ms (Opening)
ApplicationMotor Control, Resistive Load
Electrical Durability2.3 Mcycles (11 A, AC-3, Less than 440 V), 0.8 Mcycles (25 A, AC-1, Less than 440 V), 2.3 Mcycles (11 A, AC-3e, Less than 440 V)
Signalling Circuit Frequency25 to 400 Hz
FeaturesBuilt-In Bi-Directional Peak Limiting
Mechanical Durability15 Mcycles
Impedance2.5 mOhm
Max. Temperature850°C
Non-Overlap Time1.5 ms
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Environmental AttributesMercury Free, Pollution Degree 3
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
IP RatingIP20
Minimum Operating Temperature-40 Degrees F
Mounting StyleDIN Rail, Plate
NEMA Enclosure RatingNo Enclosure
Horsepower @ Single Phase - 120V AC1/2 hp
Overall Depth3.39 in
Horsepower @ Three Phase - 240V AC3 hp
Horsepower @ Three Phase - 480V AC7 1/2 hp
Embedded Surge SuppressorNo
Contactor StyleIEC
Number of Normally Open Main Contacts3
NEMA Enclosure MaterialNot Applicable
Overall Height3.03 in
Mechanical Operating Durability15,000,000
Number of Auxillary Contacts2
Full Load Current - Resistive25 A
Maximum Operating Temperature140 Degrees F
Coil Voltage100-250V AC/DC
Frequency50/60 Hz
Reversing CapabilityNon-Reversing
PhaseThree
Electrical Operating Durability2,300,000, 800,000
Horsepower @ Three Phase - 208V AC3 hp
Horsepower @ Single Phase - 240V AC2 hp
Terminal Connection TypeScrew Clamp Terminals
Includes Auxiliary ContactsYes
Full Load Current - Inductive12 A
Resistance PropertiesFire Resistant, Insulation Resistant
Overall Width1.77 in
Horsepower @ Three Phase - 600V AC10 hp
Maximum Voltage Rating690V AC
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#100 to 250 V AC/DC
#12 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D12KUE
#SCHNEIDER ELECTRIC
#GRG6555530
#mfr:LC1D12KUE
#part number:LC1D12KUE
#pn:LC1D12KUE
#part code:LC1D12KUE
#item number:LC1D12KUE
#product code:LC1D12KUE
#manufacturer number:LC1D12KUE
#manufacturers part number:LC1D12KUE
#mfn:LC1D12KUE

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!