Item
IEC Magnetic Contactor
Full Load Amps-Inductive
25 A
Full Load Amps-Resistive
25 A
Aux. Contact Configuration
1NO
Enclosure NEMA Rating
3R; 4
Standards
CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
Frame / Series / Class / Code
TeSys
Special Features
Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
Application
Motor Control, Resistive Load
Features
Without Built-In Suppressor Module
Impulse Withstand Voltage
6 kV
Max. Operating Watts
5.5 kW (at 220 to 230V AC 50/60 Hz), 11 kW (at 380 to 400V AC 50/60 Hz), 11 kW (at 415V AC 50/60 Hz), 11 kW (at 440V AC 50/60 Hz), 15 kW (at 500V AC 50/60 Hz), 15 kW (at 660 to 690V AC 50/60 Hz)
Control Circuit Voltage Limits
Drop-Out: 0.1 to 0.3 Uc (at 70°C); Operational: 0.8 to 1.25 Uc (at 60°C), 1 to 1.25 Uc (at 70°C)
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Switching Current
5 mA (Signalling Circuit)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Voltage
17 V (Signalling Circuit)
Operating Speed
3600 cycles per hr
Electrical Durability
1 Mcycles (25 A, AC-3, Less than 440 V); 0.6 Mcycles (32 A, AC-1, Less than 440 V)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Thermal Amperage
10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit)
Overvoltage Category
CAT III
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Rated Insulation Volts
600/690V
Signalling Circuit Frequency
25 to 400 Hz
Rated Breaking Capacity
300 A @ 440V
Working Height
Up to 6561.68 ft
Mechanical Durability
10 Mcycles
Fuse Amps
10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Operating Time
65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening)
Electrical Connection
Screw Clamp Terminals
Rated Voltage
690V AC, 300V DC
Number of Normally Open Main Contacts
3
Embedded Surge Suppressor
No
Horsepower @ Single Phase - 120V AC
1 hp
Horsepower @ Single Phase - 240V AC
3 hp
Includes Auxiliary Contacts
Yes
Horsepower @ Three Phase - 208V AC
5 hp
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 600V AC
15 hp
Electrical Operating Durability
1,000,000, 600,000
Horsepower @ Three Phase - 480V AC
10 hp
Minimum Operating Temperature
-40 Degrees F
Full Load Current - Inductive
25 A
Full Load Current - Resistive
25 A
Terminal Connection Type
Screw Clamp Terminals
Horsepower @ Three Phase - 240V AC
5 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Reversing Capability
Non-Reversing
Maximum Operating Temperature
140 Degrees F
Number of Auxillary Contacts
1
Mounting Style
DIN Rail, Plate
Auxiliary Contact Form
1NO
Maximum Voltage Rating
690V AC
Mechanical Operating Durability
10,000,000
Country of Origin (subject to change)
Indonesia