Item
IEC Magnetic Contactor
Full Load Amps-Inductive
18 A
Full Load Amps-Resistive
18 A
HP @ 1 Phase - 120V
1/2 hp
HP @ 3 Phase - 480V
7 1/2 hp
Aux. Contact Configuration
1NO
Enclosure NEMA Rating
3R; 4
Standards
CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
Frame / Series / Class / Code
TeSys
Special Features
Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
Application
Motor Control, Resistive Load
Features
Without Built-In Suppressor Module
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Voltage
690V AC, 300V DC
Control Circuit Voltage Limits
Drop-Out: 0.3 to 0.6 Uc (at 70°C 50/60 Hz); Operational: 0.8 to 1.1 Uc (at 60°C 50 Hz 0.85 to 1.1 Uc (at 60°C 60 Hz), 1 to 1.1 Uc (at 70°C 50/60 Hz)
Electrical Durability
1 Mcycles (18 A, AC-3, Less than 440 V); 0.6 Mcycles (25 A, AC-1, Less than 440 V)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Impulse Withstand Voltage
6 kV
Max. Operating Watts
4 kW (at 220 to 230V AC 50/60 Hz), 7.5 kW (at 380 to 400V AC 50/60 Hz), 9 kW (at 415V AC 50/60 Hz), 9 kW (at 440V AC 50/60 Hz), 10 kW (at 500V AC 50/60 Hz), 10 kW (at 660 to 690V AC 50/60 Hz)
Thermal Amperage
10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Electrical Connection
Screw Clamp Terminals
Working Height
Up to 6561.68 ft
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Switching Voltage
17 V (Signalling Circuit)
Operating Speed
3600 cycles per hr
Signalling Circuit Frequency
25 to 400 Hz
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Current
5 mA (Signalling Circuit)
Rated Insulation Volts
600/690V
Mechanical Durability
10 Mcycles
Overvoltage Category
CAT III
Fuse Amps
10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Rated Breaking Capacity
250 A @ 440V
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Maximum Operating Temperature
140 Degrees F
Resistance Properties
Fire Resistant, Insulation Resistant
Auxiliary Contact Form
1NO
Mechanical Operating Durability
10,000,000
Full Load Current - Resistive
18 A
Terminal Connection Type
Screw Clamp Terminals
NEMA Enclosure Rating
No Enclosure
Electrical Operating Durability
1,000,000, 600,000
Number of Auxillary Contacts
1
Maximum Voltage Rating
690V AC
Horsepower @ Single Phase - 120V AC
1/2 hp
Includes Auxiliary Contacts
Yes
Mounting Style
DIN Rail, Plate
Number of Normally Open Main Contacts
3
Horsepower @ Three Phase - 600V AC
10 hp
Horsepower @ Single Phase - 240V AC
2 hp
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Full Load Current - Inductive
18 A
Embedded Surge Suppressor
No
Horsepower @ Three Phase - 240V AC
3 hp
Reversing Capability
Non-Reversing
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 208V AC
3 hp
Hold-In Power Consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Connections - Terminals
Power circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end
Control Circuit Type
AC 50/60 Hz
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 25 A (at 140°F (60°C)) for power circuit
Maximum Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Motor Power KW
4 kW 220 to 230 V AC 50/60 Hz; 7.5 kW 380 to 400 V AC 50/60 Hz; 9 kW 415 V AC 50/60 Hz; 9 kW 440 V AC 50/60 Hz; 10 kW 500 V AC 50/60 Hz; 10 kW 660 to 690 V AC 50/60 Hz
Rated Impulse Withstand Voltage
6 kV IEC 60947
Pole Contact Composition
3 NO
Heat Dissipation
2 to 3 W 50/60 Hz
Auxiliary Contact Composition
1 NO
Power Dissipation Per Pole
0.36 W AC-3; 1.56 W AC-1
Rated Insulation Voltage
Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1
Ambient Air Temperature For Storage
-76 to 176°F (-60 to 80°C)
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1; 40 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 25 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Product Or Component Type
Contactor
Maximum Horse Power Rating
0.5 hp at 115 V AC 50/60 Hz for 1 phase motors; 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 10 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Operating Altitude
0 to 6561.68 ft (0 to 2000 m)
Mounting Support
Rail; Plate
Utilisation Category
AC-4; AC-1; AC-3
Minimum Switching Voltage
17 V for signalling circuit
IRMS Rated Making Capacity
250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Minimum Switching Current
5 mA for signalling circuit
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
Resistive load; Motor control
IP Degree Of Protection
IP20 front face IEC 60529
Rated Operational Current
18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
Insulation Resistance
Greater than 10 MOhm for signalling circuit
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Product Certifications
UL; CSA
Control Circuit Voltage
240 V AC 50/60 Hz
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C)
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Auxiliary Contacts Type
Mechanically linked 1 NO IEC 60947-5-1
Product Name
Easy TeSys DPE
Country of Origin (subject to change)
Indonesia