Item
Electromechanical Timer
Description/Special Features
1R Enclosures in Steel or Noncorrosive Plastic, Furnished with a Maximum of 2 Trippers, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day
Nominal Max. Time Setting
24 hr
Number of Trippers Included
2
Time Setting Range
1 hr. to 23 hr.
Finish
Metal Enclosure has Gray Enamel
Packaging Applications
Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps
Motor Load Ratings
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
Tungsten Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Resistive Load Ratings
40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz; 40 A, 347 VAC, 60 Hz
Application Compatibilities
LED; HID
Product Height
7 7/8 in; 200 mm
Electronic Ballast Load Ratings Ranges
16 A, 120-277 VAC
Maximum On Off Operations
12
Pilot Duty Load Ratings
1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz
Electronic Ballast Load Ratings
16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC
Power Consumption Max W
3 W
Product Depth
3 7/16 in; 87.3 mm
Market
Commercial; Industrial
Operating Temperature Max
130°C
Minimum On Off Time
1 hour
UL Cerfication File Number
UL917
Inductive Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Skipper Wheel Operation Mode
Not Included
Knockout Dimensions Bottom
(2) combination 1/2
Has Manual Override CVL
Yes
Input Voltage Ranges
208-277 VAC, 60 Hz
Resistive Load Ratings Ranges
40 A, 120-480 VAC, 60 Hz
Pilot Duty Load Ratings Ranges
1000 VA, 120-277 VAC, 60 Hz
Inductive Load Ratings
40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
Knockout Dimensions Back
(1) combination 1/2
Tungsten Load Ratings
40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz
Product Width
5 1/8 in; 130.2 mm
Operating Temperature Min
-40°C
Solutions
Machinery u0026 Pumps; Panel Integrators
Applications
Timing/Scheduling ON/OFF; Indoor Lighting Control
Tungsten Range(s)
40 A, 120-277 VAC, 60 Hz
Tungsten (NO)
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
Operating Temperature Min (°F)
-40
Operating Temperature Max (°F)
130
Inductive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
Skipper Wheel
Not Included
Maximum Power Consumption (W)
3 W
Resistive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 347 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz
Features
Direct 24-hour control of most loads; Up to 12 ON/OFF operations each day with minimum ON/OFF times of one hour; Manual override; One ON and one OFF tripper included; Can be installed in most Intermatic enclosures
Motor Load Ratings Ranges
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
Electronic Ballast
16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC
Input Voltage Range(s)
208-277 VAC, 60 Hz
Pilot Duty (NO)
1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz
Maximum ON/OFF Operations
12
Minimum ON/OFF Times
1 hour
Operating Temperature Min (°F)
-40
Operating Temperature Max (°F)
130
Country of Origin (subject to change)
Mexico