Promotion Restriction
Not eligible for promotion
Application
Fiber Optic Video Inspection
Features
Allow Tier 2 Certification, Detects (850/1300nm) Multimode and (1310/1550nm) Single Mode Wavelengths, Locate Connections and Faults, Measure Loss and Reflectance
Includes
Splices, Splitters
Calibration Certificate
Included
Line Polarity Indicator
No
Product Type
Fiber Optic Tester
Battery Chemistry
Lithium Ion
Minimum Wavelength Measurement
850 nm
Minimum Operating Temperature
32 Degrees F
Maximum Operating Temperature
122 Degrees F
Testing Functions
Fiber Verification
Number of Batteries Required
1
Fault Location Pulse Duration
2 sec
Fiber Mode Measured
Multi-Mode, Single-Mode
Maximum Wavelength Measurement
1,625 nm
Certifications
CE (when used with the mainframe)
Sample resolution
3 cm to 400 cm
Pulse widths (nominal)
5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns, 1300 nm: 3, 5, 20, 40, 200, 1000 ns || 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns || 850 nm: 3, 5, 20, 40, 200 ns
Tester Off
Four hours to charge from 10% to 90% capacity
On/Off control
Mechanical switch and a button on the touch screen
Laser safety (classification)
Class II CDRH Complies to EN 60825-2
Sampling points
Up to 129000
Distance uncertainty
+/-(1 + 0. 0005*distance + 0. 5*resolution)
Event dead zone 1
0. 7 m (typical), 1550 nm: 0. 6 m typical || 1310 nm: 0. 6 m typical || 850 nm: 0. 5 m typical || 1300 nm: 0. 7 m typical
Temperature range
Operating: 32°F to 122°F (0 °C to +50 °C) || Storage: -4°F to +158°F (-20°C to +70°C)
Reflectance uncertainty
±2 dB
PON dead zone3
30 m (typical)
Storage Temperature
-10ºC to +60ºC
Attenuation dead zone2
4m (typical)
Minimum detectable particle size
0. 5 µm
Magnification
~ 200X with OptiFiber Pro Display
Dynamic range 4, 5
1310 nm: 42 dB (typical || 1490 nm: 41 dB (typical) || 1625 nm: 40 dB (typical) || 1550 nm: 41 dB (typical) || 1310 nm: 42 dB (typical)
Power source
Versiv mainframe
Battery
Lithium ion battery pack, 7. 2 volts
Tester On
Six hours to charge from 10% to 90% capacity with the tester on
Operating altitude
4,000 m (13123 ft) || 3200 m (10,500 ft) with ac adapter
Operating wavelength
650 nm nominal
Dynamic range 3, 5, 6
1300 nm: 30 dB typical || 850 nm: 28 dB typical || 1550 nm: 30 dB typical || 1310 nm: 32 dB typical
Wavelengths
850 nm +/- 10 nm || 1300 nm +35/-15 nm || 1550 nm +/- 30 nm || 1310 nm +/- 25 nm, 1490 nm +/- 20 nm || 1550 nm +/- 20 nm || 1310 nm +/- 25 nm || 1625 nm +/- 20 nm
Dimensions
Mainframe with module and battery: 2. 625 in x 5. 25 in x 11. 0 in ( 6. 67 cm x 13. 33 cm x 27. 94 cm)
Compatible fiber types
50/125 µm || 62. 5/125 µm || Singlemode, Singlemode
Output power
316 µW (-5 dBm) = peak power = 1. 0 mW (0 dBm)
OTDR Port Connector
Cleanable APC ferrule with removable SC adapter
Field of View (FOV)
Horizontal: 425 µm || Vertical: 320 µm
Max distance range setting
260 km, 40 km || MM: 40 km || SM: 130 km || 130 km
Laser classification
Class 1 CDRH Complies to EN 60825-2, 3rd Edition
Operating temperature
-10ºC to 45ºC
Sampling resolution
3 cm to 2 m
Spectral width (RMS)
±3 nm
Battery life
Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Attenuation dead zone 2
1310 nm: 3. 6 m typical || 1300 nm: 4. 5 m typical || 850 nm: 2. 5 m typical || 1550 nm: 3. 7 m typical
Output modes
Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Reflectance range4
-14 to -70 dB (typical)
Integrated Wi-Fi
Meets IEEE 802. 11 a/b/g/n; dual band (2. 4 GHz and 5 GHz)
Connector adapter
2. 5 mm universal
Reflectance range 4, 5
1300 nm: -14 dB to -62 dB (typical) || 1310 nm: -14 dB to -65 dB (typical) || 1310 nm: -14 dB to -65dB (typical) || 1550 nm: -14 dB to -65 dB (typical) || 850 nm: -14 dB to -57 dB (typical)
Test Time (per wavelength)
Best resolution setting: 5 to 180 seconds/wavelength || Auto PON setting: 10 seconds/wavelength (typical) || Quick test setting: 3 seconds/wavelength (typical) || Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Auto setting: 5 seconds/wavelength (typical), || Best resolution setting: 5 to 180 sec || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || Auto setting: 10 sec (typical) || Quick test setting: 2 sec (typical) || MM - 2 sec (typical), MM - 180 sec (max) || Manual setting: || -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max) || DataCenter OTDR setting: || SM - 10 sec (typical), SM - 180 sec (max) || Auto setting: 5 sec (typical) || FaultMap setting: 10 sec (typical), 180 sec (max) || FaultMap setting: || Best resolution setting: 2 to 180 sec || MM “ 1 sec (typical at 850 nm) MM “ 7 sec (max) || MM “ 2 sec (typical) || Quick test setting: || DataCenter OTDR setting: 20 sec (typical), 40 sec (max) || MM “ 2 to 180 sec M || SM “ 10 sec (typical) || SM “ 5 sec (typical) || FaultMap setting: 2 sec (typical), 180 sec (max) || Quick test setting: 5 sec (typical) || MM “ 5 sec (typical) || SM “ 5 to 180 sec || Best resolution setting: || SM “ 20 sec (typical) SM “ 40 sec (max) || Auto setting:
Distance measurement range 4, 5, 7, 8, 9, 10
1310 nm: 80 km || 850 nm: 9 km || 1550 nm: 130 km || 1300 nm: 35 km
Country of Origin (subject to change)
United States