Promotion Restriction
Not eligible for promotion
Multimeter Style
Full Size - General Features
Basic DC Accuracy
+/-0.15% of Reading + 2 Digits
Instrument Safety Rating
CAT III 1000V, CAT IV 600V
Capacitance Range
1 nF to 9999 uF
Special Features
Closed Case Calibration Through Front Panel, Ergonomic Case with Integrated Protective Holster
Calibration Certificate Included
Yes
Instrument Frequency Counter Range
0.01 Hz to 100 kHz
Series
FLUKE (R) Fluke-175
NIST Certification By
Techni-Tool
Standards
CSA, EN61010-1, TUV, UL, VDE
Manufacturers Warranty Length
Lifetime
Includes
(1 Pair) Test Leads, 9V Battery (Installed), Quick Reference Guide
Temp. Range
14 Degrees to 122 Degrees F
Calibration Certificate
Included
Parameters Measured
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance
Maximum AC Voltage Measurement
1,000 V
Minimum Operating Temperature
14 Degrees F
Minimum Storage Temperature
-22 Degrees F
Maximum DC Voltage Measurement
1,000 V
Resistance Measurement Resolution
Not Applicable
Current Leakage Testing
No
Temperature Measurement Accuracy
Not Applicable
DC Voltage Measurement Resolution
Not Applicable
Minimum Capacitance Measurement
1 nF
Maximum DC Current Measurement
10 A
Minimum AC Voltage Measurement
0 V
Maximum Frequency Measurement
100 kHz
Minimum AC Current Measurement
0 A
Maximum Operating Temperature
122 Degrees F
Maximum AC Current Measurement
10 A
Minimum Frequency Measurement
0.01 Hz
Maximum Storage Temperature
140 Degrees F
NIST Certification By Manufacturer
Techni-Tool
Battery Chemistry
Alkaline
Maximum Capacitance Measurement
9,999 uF
Minimum DC Voltage Measurement
0 V
Min-Max-Avg Button Included
Yes
Basic AC Current Accuracy
+/-1.5% + 3
Maximum Resistance Measurement
50 megaohm
Basic DC Voltage Accuracy
+/-0.15% + 2 Digits
Multimeter Features
Data Logging
AC Current Measurement Resolution
Not Applicable
Resistance Measurement Accuracy
+/-0.9%
Minimum/Maximum Memory
Yes
Capacitance Measurement Accuracy
1.20 % + 2
Basic AC Voltage Accuracy
+/-1% + 3
Minimum Temperature Measurement
14 Degrees F
Frequency Measurement Accuracy
0.10 % + 1
AC Voltage Measurement Resolution
Not Applicable
Minimum DC Current Measurement
0 A
Maximum Temperature Measurement
122 Degrees F
DC Current Measurement Resolution
Not Applicable
Basic DC Current Accuracy
+/-1% + 3
Capacitance Measurement Resolution
1 nF
Frequency Measurement Resolution
0.01 Hz
Computer Interface Connection Type
None
AC Response Calculation
TRMS
Country of Origin (subject to change)
United States