AC Contact Rating - Relay | 1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1 |
DC Contact Rating - Relay | 5 A DC-1, 3 A DC-13, 3 A DC-1, 1 A DC-13 |
Mounting - Relay | DIN Rail |
Input Power Consumption (Burden) | 3 W |
Delay Time - Relay | Sync time between inputs: 0.5s 2s 4 s |
Body Width - Relay | 1.77 in |
Environmental Protection | Dust & Splash Resistant |
Depth | 120 mm |
Width | 45 mm |
Body Height - Relay | 3.94 in |
Overall Height - Relay | 3.94 in |
Body Depth - Relay | 4.72 in |
Item | Force |
Standards | IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard |
Height | 100 mm |
Electrical Connection - Relay | Screw Terminal, Terminal Block Removable |
Electrical Connection Type | Screw |
Relay Mounting Style | DIN-Rail |
Input Compatibility | normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP |
[Us] Rated Supply Voltage | 24 V AC - 15...10 % || 24 V DC - 20...20 % |
Input/Output Type | semiconductor output 24 V DC, 20 mA Z2, not safety-related || pulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related |
Product Certifications | TUV || cULus |
Electrical Circuit Type | NC pair || PNP pair || antivalent pair || OSSD pair |
Input Protection Type | internal, electronic |
Time Delay Range | 0...900 s off |
Safety Level | can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508 |
Minimum Output Current | 20 mA relay output |
Minimum Output Voltage | 24 V relay output |
Mounting Support | 35 mm symmetrical DIN rail |
[Uimp] Rated Impulse Withstand Voltage | 4 kV II EN/IEC 60947-1 |
Ip Degree Of Protection | IP54 mounting area)EN/IEC 60947-1 || IP40 housing)EN/IEC 60947-1 || IP20 terminals)EN/IEC 60947-1 |
Number Of Inputs | 2 positive safety input 24 V DC 8 || 1 negative safety input |
Product Or Component Type | safety module |
Power Consumption In W | 3 W 24 V DC |
Safety Module Application | monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring || monitoring of pressure-sensitive 4-wire protective devices |
Power Consumption In Va | 6.5 VA 24 V AC 50/60 Hz |
Maximum Line Resistance | 500 Ohm |
Ambient Air Temperature For Storage | -25-85°C |
Connections - Terminals | removable screw terminal block, 0.2...2.5 mm? solid or flexible || removable screw terminal block, 0.25...2.5 mm? flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm? solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm? flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm? flexible with ferrule with cable end, with bezel |
[Ie] Rated Operational Current | 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact |
Safety Module Name | XPSUAT |
[Ith] Conventional Free Air Thermal Current | 16 A |
Function Of Module | emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || sensing mat/edges || proximity sensor monitoring || monitoring 1 PNP + 1 NPN sensor |
[Ui] Rated Insulation Voltage | 250 V 2)EN/IEC 60947-1 |
Associated Fuse Rating | 10 A gG NO relay output circuit IEC 60947-1 |
Type Of Start | automatic/manual/monitored |
Maximum Response Time On Input Open | 20 ms |
Relative Humidity | 5-95 % non-condensing |
Number Of Outputs | 4 on/off configurable pulsed output |
Synchronisation Time Between Inputs | 0.5 s || 2 s || 4 s |
Auxiliary Contact Composition | 1 NC configurable || 3 NO configurable || 3 NO immediate |
Minimum Operating Temperature | -13 Degrees F |
Maximum Operating Temperature | 185 Degrees F |
Safety Outputs | 1 NC configurable, 3 NO configurable, 3 NO immediate |
Rated Impulse Withstand Voltage | 4 kV II IEC 60947-1 |
Rated Insulation Voltage | 250 V 2)IEC 60947-1 |
Rated Operational Current | 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact, 3 A AC-1 for normally closed relay contact, 1 A AC-15 for normally closed relay contact, 3 A DC-1 for normally closed relay contact, 1 A DC-13 for normally closed relay contact |
Rated Supply Voltage | 24 V AC - 15 to 10%, 24 V DC - 20 to 20% |
Safety Inputs | 2 positive safety input 24 V DC 8 mA, 1 negative safety input |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
Force, DIN Rail, 4.72" D, 3.94" H, 1.77"W, 3W, SCHNEIDER, Mfr# XPSUAT13A3AP
$452,99
Free shipping will be applied on orders over $50
Force, Maximum Operating Temperature 185 Degrees F, Minimum Operating Temperature -13 Degrees F
0 in stock
Must order in multiples of 1
Subtotal:
$452.99
You must be logged in to post a review.
Reviews