AC Contact Rating - Relay | 1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1 |
DC Contact Rating - Relay | 5 A DC-1, 3 A DC-13, 3 A DC-1, 1 A DC-13 |
Mounting - Relay | DIN Rail |
Input Power Consumption (Burden) | 4.5 W |
Delay Time - Relay | Sync time between inputs: 0.5s 2s 4 s |
For Use With | Guard Switch, Magnetic Switch, Monitoring Emergency Stop, PNP Sensors, Proximity Safety Switch, RFID Safety Switch or Safety Light Curtain |
Body Depth - Relay | 4.72 in |
IP Rating | IP20, IP40, IP54 |
Response Time | 20 msec |
Item | Force |
Height | 100 mm |
Body Width - Relay | 1.77 in |
Overall Depth | 3.9 in |
Power Consumption | 4.5 W |
Depth | 120 mm |
Standards | CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified |
Overall Height - Relay | 3.94 in |
Body Height - Relay | 3.94 in |
Width | 45 mm |
Environmental Protection | Dust & Splash Resistant |
Mounting Style | DIN Rail |
Application | Emergency Stops |
Input Voltage | 24V AC/DC |
Electrical Connection - Relay | Screw Terminal, Terminal Block Removable |
Weight | 12.35 oz |
Relay Mounting Style | DIN-Rail |
Electrical Connection Type | Screw |
Number of Input Channels | 6 |
Maximum Operating Temperature | 185 Degrees F |
Contact Rating (DC) | 1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO) |
Body Width | 1.77 in |
Delay Time | 0.5 sec, 2 sec, 4 sec |
Delay Type | Adjustable |
Body Depth | 4.72 in |
Electrical Connection | Screw Terminal, Terminal Block Removable |
Frequency | 50/60 Hz |
Minimum Operating Temperature | -13 Degrees F |
Contact Rating (AC) | 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO) |
Body Height | 3.94 in |
Safety Reliability Data | Dcavg Greater Than= 99% Conforming to ISO 13849-1, HFT = 1 Conforming to IEC 61508-1, HFT = 1 Conforming to IEC 62061, MTTFd Greater Than 30 years Conforming to ISO 13849-1, PFHd = 0.88E-09 Conforming to IEC 61508-1, PFHd = 0.88E-09 Conforming to IEC 62061, PFHd = 0.88E-09 Conforming to ISO 13849-1, SFF Greater Than 99% Conforming to IEC 61508-1, SFF Greater Than 99% Conforming to IEC 62061, Type = B Conforming to IEC 61508-1 |
Input Protection Type | internal, electronic |
Local Signalling | for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety input S23 LED (yellow) || for safety input S32 LED (yellow) || for safety input S33 LED (yellow) || for safety input S42 LED (yellow) || for safety input S43 LED (yellow) || for safety input S52 LED (yellow) || for safety input S53 LED (yellow) || for safety input S62 LED (yellow) || for safety input S73 LED (yellow) |
Maximum Line Resistance | 500 Ohm |
Power Consumption In Va | 10.5 VA 24 V AC 50/60 Hz |
Product Or Component Type | safety module |
[Ie] Rated Operational Current | 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact |
Safety Module Name | XPSUDN |
Type Of Start | automatic/manual/monitored |
Function Of Module | emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring |
[Uimp] Rated Impulse Withstand Voltage | 4 kV II EN/IEC 60947-1 |
Mounting Support | 35 mm symmetrical DIN rail |
Number Of Outputs | 7 on/off configurable pulsed output |
[Ith] Conventional Free Air Thermal Current | 16 A |
[Ui] Rated Insulation Voltage | 250 V 2)EN/IEC 60947-1 |
Associated Fuse Rating | 10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1 |
Product Certifications | TUV || cULus |
Number Of Inputs | 6 safety input 24 V DC 5 |
Relative Humidity | 5-95 % non-condensing |
Power Consumption In W | 4.5 W 24 V DC |
Safety Module Application | monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring |
Minimum Output Voltage | 12 V relay output |
Electrical Circuit Type | NC pair || PNP pair || antivalent pair || OSSD pair |
Ip Degree Of Protection | IP20 terminals)EN/IEC 60947-1 || IP40 housing)EN/IEC 60947-1 || IP54 mounting area)EN/IEC 60947-1 |
Safety Level | can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508 |
Ambient Air Temperature For Storage | -25-85°C |
Synchronisation Time Between Inputs | 0.5 s || 2 s || 2.2 s || 4 s |
Ambient Air Temperature For Operation | -25-50°C at 24 V AC || -25-55°C at 24 V DC |
Maximum Response Time On Input Open | 20 ms |
[Us] Rated Supply Voltage | 24 V AC - 15...10 % || 24 V DC - 20...20 % |
Connections - Terminals | removable screw terminal block, 0.2...2.5 mm? solid or flexible || removable screw terminal block, 0.25...2.5 mm? flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm? solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm? flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm? flexible with ferrule with cable end, with bezel |
Input Compatibility | normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP |
Minimum Output Current | 10 mA relay output |
Auxiliary Contact Composition | 3 NO + 1 NC |
Input/Output Type | semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
Rated Supply Voltage | 24 V AC - 15 to 10%, 24 V DC - 20 to 20% |
Rated Operational Current | 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact, 3 A AC-1 for normally closed relay contact, 1 A AC-15 for normally closed relay contact, 3 A DC-1 for normally closed relay contact, 1 A DC-13 for normally closed relay contact |
Safety Inputs | 6 safety input 24 V DC 5 mA |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
Force, DIN Rail, 4.72"D, 3.94"H, 1.77"W, 4.5W, SCHNEIDER, Mfr# XPSUDN13AP
$355,99
Free shipping will be applied on orders over $50
Force, Delay Time 0.5 sec, 2 sec, 4 sec, Delay Type Adjustable, Electrical Connection Screw Terminal, Terminal Block Removable, IP Rating IP20; IP40; IP54, Input Voltage 24V AC/DC, Mounting Style DIN Rail, Response Time 20 msec, Standards CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified, Contact Rating (AC) 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO), Contact Rating (DC) 1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO)
0 in stock
Must order in multiples of 1
Subtotal:
$355.99
You must be logged in to post a review.
Reviews
There are no reviews yet.