Force, DIN Rail, 4.72"D, 3.94"H, 1.77"W, 4.5W, SCHNEIDER, Mfr# XPSUDN13AP

$355,99
Free shipping will be applied on orders over $50

Force, Delay Time 0.5 sec, 2 sec, 4 sec, Delay Type Adjustable, Electrical Connection Screw Terminal, Terminal Block Removable, IP Rating IP20; IP40; IP54, Input Voltage 24V AC/DC, Mounting Style DIN Rail, Response Time 20 msec, Standards CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified, Contact Rating (AC) 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO), Contact Rating (DC) 1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO)

0 in stock

Must order in multiples of 1
Subtotal:
$355.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER
Mfr #: XPSUDN13AP
Availability: Ships in 18 days
SKU: GRG003529055 Category:
AC Contact Rating - Relay1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1
DC Contact Rating - Relay5 A DC-1, 3 A DC-13, 3 A DC-1, 1 A DC-13
Mounting - RelayDIN Rail
Input Power Consumption (Burden)4.5 W
Delay Time - RelaySync time between inputs: 0.5s 2s 4 s
For Use WithGuard Switch, Magnetic Switch, Monitoring Emergency Stop, PNP Sensors, Proximity Safety Switch, RFID Safety Switch or Safety Light Curtain
Body Depth - Relay4.72 in
IP RatingIP20, IP40, IP54
Response Time20 msec
ItemForce
Height100 mm
Body Width - Relay1.77 in
Overall Depth3.9 in
Power Consumption4.5 W
Depth120 mm
StandardsCCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified
Overall Height - Relay3.94 in
Body Height - Relay3.94 in
Width45 mm
Environmental ProtectionDust & Splash Resistant
Mounting StyleDIN Rail
ApplicationEmergency Stops
Input Voltage24V AC/DC
Electrical Connection - RelayScrew Terminal, Terminal Block Removable
Weight12.35 oz
Relay Mounting StyleDIN-Rail
Electrical Connection TypeScrew
Number of Input Channels6
Maximum Operating Temperature185 Degrees F
Contact Rating (DC)1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO)
Body Width1.77 in
Delay Time0.5 sec, 2 sec, 4 sec
Delay TypeAdjustable
Body Depth4.72 in
Electrical ConnectionScrew Terminal, Terminal Block Removable
Frequency50/60 Hz
Minimum Operating Temperature-13 Degrees F
Contact Rating (AC)1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO)
Body Height3.94 in
Safety Reliability DataDcavg Greater Than= 99% Conforming to ISO 13849-1, HFT = 1 Conforming to IEC 61508-1, HFT = 1 Conforming to IEC 62061, MTTFd Greater Than 30 years Conforming to ISO 13849-1, PFHd = 0.88E-09 Conforming to IEC 61508-1, PFHd = 0.88E-09 Conforming to IEC 62061, PFHd = 0.88E-09 Conforming to ISO 13849-1, SFF Greater Than 99% Conforming to IEC 61508-1, SFF Greater Than 99% Conforming to IEC 62061, Type = B Conforming to IEC 61508-1
Input Protection Typeinternal, electronic
Local Signallingfor power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety input S23 LED (yellow) || for safety input S32 LED (yellow) || for safety input S33 LED (yellow) || for safety input S42 LED (yellow) || for safety input S43 LED (yellow) || for safety input S52 LED (yellow) || for safety input S53 LED (yellow) || for safety input S62 LED (yellow) || for safety input S73 LED (yellow)
Maximum Line Resistance500 Ohm
Power Consumption In Va10.5 VA 24 V AC 50/60 Hz
Product Or Component Typesafety module
[Ie] Rated Operational Current5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
Safety Module NameXPSUDN
Type Of Startautomatic/manual/monitored
Function Of Moduleemergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring
[Uimp] Rated Impulse Withstand Voltage4 kV II EN/IEC 60947-1
Mounting Support35 mm symmetrical DIN rail
Number Of Outputs7 on/off configurable pulsed output
[Ith] Conventional Free Air Thermal Current16 A
[Ui] Rated Insulation Voltage250 V 2)EN/IEC 60947-1
Associated Fuse Rating10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1
Product CertificationsTUV || cULus
Number Of Inputs6 safety input 24 V DC 5
Relative Humidity5-95 % non-condensing
Power Consumption In W4.5 W 24 V DC
Safety Module Applicationmonitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
Minimum Output Voltage12 V relay output
Electrical Circuit TypeNC pair || PNP pair || antivalent pair || OSSD pair
Ip Degree Of ProtectionIP20 terminals)EN/IEC 60947-1 || IP40 housing)EN/IEC 60947-1 || IP54 mounting area)EN/IEC 60947-1
Safety Levelcan reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508
Ambient Air Temperature For Storage-25-85°C
Synchronisation Time Between Inputs0.5 s || 2 s || 2.2 s || 4 s
Ambient Air Temperature For Operation-25-50°C at 24 V AC || -25-55°C at 24 V DC
Maximum Response Time On Input Open20 ms
[Us] Rated Supply Voltage24 V AC - 15...10 % || 24 V DC - 20...20 %
Connections - Terminalsremovable screw terminal block, 0.2...2.5 mm? solid or flexible || removable screw terminal block, 0.25...2.5 mm? flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm? solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm? flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm? flexible with ferrule with cable end, with bezel
Input Compatibilitynormally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Minimum Output Current10 mA relay output
Auxiliary Contact Composition3 NO + 1 NC
Input/Output Typesemiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Rated Supply Voltage24 V AC - 15 to 10%, 24 V DC - 20 to 20%
Rated Operational Current5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact, 3 A AC-1 for normally closed relay contact, 1 A AC-15 for normally closed relay contact, 3 A DC-1 for normally closed relay contact, 1 A DC-13 for normally closed relay contact
Safety Inputs6 safety input 24 V DC 5 mA
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#Force
#DIN Rail
#4.72"D
#3.94"H
#1.77"W
#4.5W
#SCHNEIDER
#Mfr XPSUDN13AP
#SCHNEIDER
#GRG003529055
#mfr:XPSUDN13AP
#part number:XPSUDN13AP
#pn:XPSUDN13AP
#part code:XPSUDN13AP
#item number:XPSUDN13AP
#product code:XPSUDN13AP
#manufacturer number:XPSUDN13AP
#manufacturers part number:XPSUDN13AP
#mfn:XPSUDN13AP

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!