Item | High Pressure Blower |
Type | Backward Incline |
Wheel Dia. (In.) | 16 1/2 in |
Voltage | 230/460 |
Motor HP | 7.5 hp |
Inlet Dia. (In.) | 17 5/8 in |
Max. Ambient Temp. (F) | 120 Degrees F |
CFM @ 11.00-In. SP | 2815 |
Dimension C (In.) | 32 in |
Rotation | CW |
CFM @ 6.000-In. SP | 3940 |
CFM @ 1.000-In. SP | 4645 |
Motor RPM | 3,600 RPM |
Housing Length (In.) | 32 1/2 in |
Bearing Type | Regreasable Ball |
Motor HP Range | 7-1/2 |
CFM @ 4.000-In. SP | 4235 |
Dimension A (In.) | 32 1/2 in |
Blower RPM | 3,500 |
Wheel Material | Steel |
Discharge Height (In.) | 10 in |
Housing Width (In.) | 29 7/8 in |
CFM @ 3.000-In. SP | 4375 |
dBA @ 5 Feet | 94 |
Motor Frame | 213T |
Discharge Width (In.) | 18 7/16 in |
Max. Blower RPM | 3,600 |
Shaft Dia. (In.) | 1 3/8 in |
CFM @ 8.000-In. SP | 3600 |
Full Load Amps | 8.67 A |
Hz | 60 |
CFM @ 7.000-In. SP | 3770 |
Motor Type | Three Phase |
CFM @ 9.000-In. SP | 3382 |
CFM @ 2.000-In. SP | 4510 |
Dimension D (In.) | 17 5/8 in |
Phase | 3 |
CFM @ 5.000-In. SP | 4095 |
Housing Material | Steel |
Dimension B (In.) | 29 7/8 in |
Housing Height (In.) | 32 in |
Housing Finish | Enamel Paint |
Max. Inlet Temp. (Deg. F) | 150 Degrees F |
Dimension E (In.) | 10 in |
Motor Enclosure | Totally Enclosed Fan-Cooled |
Motor Insulation | Class F |
Wheel Width (In.) | 5 7/8 in |
CFM @ 10.00-In. SP | 3135 |
Flange Type | Flanged |
Airflow @ 4.000 in SP | 4,235 cfm |
Airflow @ 11.00 in SP | 2,815 cfm |
Wheel/Housing Material | Steel Wheel and Steel Housing |
Airflow @ 6.000 in SP | 3,940 cfm |
Motor Enclosure Design | Totally Enclosed Fan-Cooled (TEFC) |
Maximum Fan Speed | 3,600 RPM |
Frequency | 60 Hz |
Housing Depth | 32 1/2 in |
Outlet Shape | Rectangular |
Wheel Type | Backward-Inclined |
Motor Frame Designation | 213T |
Outlet Height | 10 in |
Motor Horsepower | 7 1/2 hp |
Shaft Diameter | 1 3/8 in |
Motor Enclosure Design_Table | Totally Enclosed Motor |
Outlet Size (H x W) | 10 in x 18 3/8 in |
Airflow @ 1.000 in SP Range | 2000 to 4999 cfm |
Airflow @ 5.000 in SP | 4,095 cfm |
Airflow @ 1.000 in SP | 3,135 cfm |
Motor Speed | 3,600 RPM |
Wheel Dimensions | 16 1/2 in Dia. x 5 7/8 in W |
Wheel Width | 5 7/8 in |
Outlet Diameter | Not Applicable |
Motor Insulation Class | F |
Airflow @ 7.000 in SP | 3,770 cfm |
Inlet Diameter | 17 5/8 in |
Housing Material Finish | Enamel |
Nameplate Voltage | 230/460V AC |
Maximum Ambient Temperature | 120 Degrees F |
Number of Inlets | 1 |
Wheel Diameter | 16 1/2 in |
Maximum Inlet Air Temperature | 150 Degrees F |
Nominal Voltage | 230/460V AC |
Outlet Width | 18 7/16 in |
Airflow @ 8.000 in SP | 3,600 cfm |
Housing Width | 29 7/8 in |
Housing Height | 32 in |
Minimum Fan Speed | 3,500 RPM |
Sound Level | 94 dBA @ 5 ft |
Airflow @ 9.000 in SP | 3,382 cfm |
Airflow @ 3.000 in SP | 4,375 cfm |
Airflow @ 2.000 in SP | 4,510 cfm |
Current | 8.67 A |
Country of Origin (subject to change) | United States |
Package Quantity | 1 |
High Pressure Blower, 3 Phase, 7-1/2 HP, CHICAGO BLOWER, Mfr# 165-7.5HP
$3409,99
Free shipping will be applied on orders over $50
High Pressure Blower, Wheel Type Backward-Inclined, Wheel Diameter 16 1/2 in, Airflow @ 1.000 in SP 3,135 cfm, Airflow @ 2.000 in SP 4,510 cfm, Airflow @ 3.000 in SP 4,375 cfm, Airflow @ 4.000 in SP 4,235 cfm, Airflow @ 5.000 in SP 4,095 cfm, Airflow @ 6.000 in SP 3,940 cfm, Airflow @ 7.000 in SP 3,770 cfm, Airflow @ 8.000 in SP 3,600 cfm, Airflow @ 9.000 in SP 3,382 cfm, Airflow @ 11.00 in SP 2,815 cfm
0 in stock
Must order in multiples of 1
Subtotal:
$3409.99
You must be logged in to post a review.
Reviews
There are no reviews yet.