Item - Relay
IEC Style Control Relay
AC Contact Rating - Relay
10A @ 120/240/480/600V
DC Contact Rating - Relay
2.00A @ 125/250/600V
Contact Form - Relay
(4) SPST-NO
Mounting - Relay
DIN Rail, Surface
Hz - Electrical
50 Hz, 60 Hz
Overall Height - Relay
2.28 in
Standards
CCC, CSA Certified, EAC, IEC, REACH, RoHS Compliant, UL Listed
Contact Amp Rating (Resistive)
10A
Body Depth - Relay
2.24 in
Contact Material
Silver Nickel
Body Width - Relay
1.77 in
Response Time
10 to 20 msec (Coil De-Energisation and NO Opening), 10 to 20 msec (Coil Energisation and NO Closing)
Power Consumption - Relay
4.5 VA
Body Height - Relay
2.28 in
Coil Rating
30VA Inrush, 4.5VA Sealed
Operating Time
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Immunity To Microbreaks
2 ms
Product Or Component Type
control relay
Non Overlap Distance
0.5 mm
Tightening Torque
1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
Mounting Support
rail || plate
Hold-In Power Consumption In Va
4.5-4.5 VA 20°C)
[Uc] Control Circuit Voltage
230...240 V AC 50/60 Hz
Utilisation Category
DC-13 || AC-15
Connections - Terminals
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end
Inrush Power In Va
30-30 VA 20°C)
Control Circuit Voltage Limits
drop-out 0.2...0.75 Uc 50°C) || operational 0.8...1.15 Uc 50°C)
Minimum Switching Current
5 mA
Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
[Ui] Rated Insulation Voltage
690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14
Associated Fuse Rating
10 A gG IEC 60947 || 10 A gG VDE 0660
Maximum Operating Rate
10000 cyc/h
Minimum Switching Voltage
17 V
Insulation Resistance
u003e 10 MOhm
Irms Rated Making Capacity
110 A IEC 60947
Operating Altitude
6561.68 ft (2000 m) without derating
Contactor Application
control circuit
Heat Dissipation
1.3-1.3 W
Mechanical Durability
10 Mcycles
Protective Treatment
TC IEC 60068
Ip Degree Of Protection
IP2X
Ambient Air Temperature For Storage
-50-80°C
Pole Contact Composition
4 NO
Ambient Air Temperature For Operation
-25-50°C
Control Circuit Type
AC 50/60 Hz
[Ith] Conventional Free Air Thermal Current
10 A 50°C
[Ue] Rated Operational Voltage
u003c= 690 V u003c= 400 Hz
Flame Retardance
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
Electrical Connection
Screw Clamp
Compatible with Series
TeSys SK Mini Control Relays
Maximum Operating Temperature
122 Degrees F
Contact Rating (AC)
10 A @ 120/240/480/600V
Contact Rating (DC)
2 A @ 125/250/600V
Mounting Style
DIN Rail and Surface
Minimum Operating Temperature
-13 Degrees F
Country of Origin (subject to change)
Indonesia