Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 65 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$391.87
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D65AB7
Availability: Ships in 1 days
SKU: GRG2830545 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive65 A
Full Load Amps-Resistive80 A
ActionNon-Reversing
Number of Poles3
Coil Volts24 V AC
ReversingNo
HP @ 1 Phase - 120V5 hp
HP @ 1 Phase - 230V10
HP @ 1 Phase - 240V10 hp
Height4.8 in
Width2.17 in
HP @ 3 Phase - 208V20 hp
HP @ 3 Phase - 240V20 hp
HP @ 3 Phase - 575V50 hp
Depth4.72 in
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V40 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
StandardsCCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
Auxiliary Contact Form1NO/1NC
NEMA SizeNot Applicable
IncludesEverlink Power Connections
SeriesTeSys Deca
Electrical ConnectionScrew Clamp Terminals
Hold VA13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Max. Operating Watts11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Signalling Circuit Frequency25 to 400 Hz
IP RatingIP20
ApplicationMotor Control, Resistive Load
Overvoltage CategoryCAT III
Working HeightUp to 9842.52 ft
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Breaking Capacity1000 A @ 440V
Fire RatingUL 94 V1
Impulse Withstand Voltage6 kV
Impedance1.5 mOhm
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Mechanical Durability6 Mcycles
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Thermal Amperage10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Non-Overlap Time1.5 ms
Rated Voltage690V AC, 300V DC
Rated Insulation Volts600/690V
FeaturesWithout Built-In Suppressor Module
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Rated Short-Time Withstand Current520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Electrical Durability1.4 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (65 A, AC-3, Less than 440 V), 1.45 Mcycles (65 A, AC-3e, Less than 440 V)
Max. Temperature850°C
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Watts Loss4 to 5W
Fuse Amps10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Net Weight0.86 kg
Inrush VA140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
Operating Speed3600 cycles per hr
Mounts OnPlate, Rail
Switching Current5 mA (Signalling Circuit)
Includes Protective CoverYes
Switching Voltage17 V (Signalling Circuit)
Overall Width2.17 in
Full Load Current - Resistive80 A
Embedded Surge SuppressorNo
Horsepower @ Three Phase - 240V AC20 hp
Reversing CapabilityNon-Reversing
Number of Normally Open Main Contacts3
PhaseThree
NEMA Enclosure RatingNo Enclosure
Maximum Voltage Rating690V AC
Minimum Operating Temperature-40 Degrees F
Overall Depth4.72 in
Maximum Operating Temperature140 Degrees F
Electrical Operating Durability1,400,000, 1,450,000
Horsepower @ Three Phase - 600V AC50 hp
Resistance PropertiesFire Resistant, Insulation Resistant
Horsepower @ Three Phase - 208V AC20 hp
Terminal Connection TypeScrew Clamp Terminals
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 480V AC40 hp
Frequency50/60 Hz
Number of Auxillary Contacts2
Contactor StyleIEC
NEMA Enclosure MaterialNot Applicable
Coil Voltage24V AC
Mechanical Operating Durability6,000,000
Includes Auxiliary ContactsYes
Overall Height4.8 in
Horsepower @ Single Phase - 240V AC10 hp
Horsepower @ Single Phase - 120V AC5 hp
Full Load Current - Inductive65 A
Minimum Switching Voltage17 V for signalling circuit
Protective TreatmentTHIEC 60068-2-30
Rated Short Time Withstand Current640 A 104°F (40°C) - 10 s for power circuit, 900 A 104°F (40°C) - 1 s for power circuit, 110 A 104°F (40°C) - 10 min for power circuit, 260 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Inrush Power in VA140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Product CertificationsUL, CCC, CSA, GOST
Auxiliary Contact Composition1 NO + 1 NC
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 80 A (at 140°F (60°C)) for power circuit
Contact CompatibilityM2
Power Dissipation Per Pole9.6 W AC-1, 6.3 W AC-3, 6.3 W AC-3e
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Heat Dissipation4 to 5 W at 50/60 Hz
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1000 A at 440 V for power circuit conforming to IEC 60947
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Flame RetardanceV1 conforming to UL 94
IP Degree Of ProtectionIP20 front face IEC 60529
Contactor ApplicationMotor control, Resistive load
Compatibility CodeLC1D
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Poles Description3P
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1
Rated Impulse Withstand Voltage6 kV IEC 60947
Fire Resistance1562°F (850°C) IEC 60695-2-1
Control Circuit TypeAC 50/60 Hz standard
Maximum Horse Power Rating40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 50 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Motor Power KW11 kW at 400 V AC 50/60 Hz (AC-4), 18.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 30 kW at 380 to 400 V AC 50/60 Hz (AC-3), 37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660 to 690 V AC 50/60 Hz (AC-3), 18.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 30 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Minimum Switching Current5 mA for signalling circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 125 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Pole Contact Composition3 NO
Product Or Component TypeContactor
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Hold-In Power Consumption in VA13 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: solid without cable end
Control Circuit Voltage24 V AC 50/60 Hz
Protective CoverWith
Rated Operational Current80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms)
Mounting SupportRail, Plate
Pollution Degree3
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#65 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D65AB7
#SCHNEIDER ELECTRIC
#GRG2830545
#mfr:LC1D65AB7
#part number:LC1D65AB7
#pn:LC1D65AB7
#part code:LC1D65AB7
#item number:LC1D65AB7
#product code:LC1D65AB7
#manufacturer number:LC1D65AB7
#manufacturers part number:LC1D65AB7
#mfn:LC1D65AB7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!