Full Load Amps-Inductive | 40 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 60 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
HP @ 1 Phase - 230V | 5 |
HP @ 1 Phase - 120V | 3 hp |
HP @ 1 Phase - 240V | 5 hp |
Height | 2.17 in |
HP @ 3 Phase - 208V | 10 hp |
Width | 2.17 in |
Depth | 4.61 in |
HP @ 3 Phase - 240V | 10 hp |
HP @ 3 Phase - 575V | 30 hp |
HP @ 3 Phase - 480V | 30 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Standards | CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed |
Auxiliary Contact Form | 1NO/1NC |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Includes | Everlink Power Connections |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Rated Short-Time Withstand Current | 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Control Circuit Voltage Limits | Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C), Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
IP Rating | IP20 |
Max. Operating Watts | 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Switching Current | 5 mA (Signalling Circuit) |
Mounts On | Plate, Rail |
Switching Voltage | 17 V (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Electrical Connection | Screw Clamp Terminals |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit) |
Application | Motor Control, Resistive Load |
Rated Breaking Capacity | 800 A @ 440V |
Includes Protective Cover | Yes |
Signalling Circuit Frequency | 25 to 400 Hz |
Net Weight | 0.925 kg |
Working Height | Up to 9842.52 ft |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit) |
Overvoltage Category | CAT III |
Impulse Withstand Voltage | 6 kV |
Operating Speed | 3600 cycles per hr |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Rated Voltage | 690V AC, 300V DC |
Operating Time | 42.5 to 57.5 ms (Closing), 16 to 24 ms (Opening) |
Fire Rating | UL 94 V1 |
Rated Insulation Volts | 600/690V |
Impedance | 1.5 mOhm |
Fuse Amps | 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit) |
Mechanical Durability | 10 Mcycles |
Electrical Durability | 0.7 Mcycles (60 A, AC-1, Less than 440 V), 1.5 Mcycles (40 A, AC-3, Less than 440 V), 1.5 Mcycles (40 A, AC-3e, Less than 440 V) |
Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Max. Temperature | 850°C |
Includes Auxiliary Contacts | Yes |
Horsepower @ Single Phase - 120V AC | 3 hp |
Reversing Capability | Non-Reversing |
Frequency | 50/60 Hz |
Minimum Operating Temperature | -40 Degrees F |
Embedded Surge Suppressor | Yes |
Contactor Style | IEC |
Mechanical Operating Durability | 10,000,000 |
Horsepower @ Three Phase - 480V AC | 30 hp |
Horsepower @ Three Phase - 208V AC | 10 hp |
Electrical Operating Durability | 1,500,000, 700,000 |
Horsepower @ Three Phase - 240V AC | 10 hp |
Overall Depth | 4.72 in |
Overall Width | 2.17 in |
Full Load Current - Inductive | 40 A |
Horsepower @ Three Phase - 600V AC | 30 hp |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Single Phase - 240V AC | 5 hp |
NEMA Enclosure Rating | No Enclosure |
Phase | Three |
Terminal Connection Type | Screw Clamp Terminals |
Maximum Operating Temperature | 140 Degrees F |
Mounting Style | DIN Rail, Plate |
Coil Voltage | 24V DC |
Number of Auxillary Contacts | 2 |
Maximum Voltage Rating | 690V AC |
Resistance Properties | Fire Resistant, Insulation Resistant |
Full Load Current - Resistive | 60 A |
Overall Height | 4.8 in |
NEMA Enclosure Material | Not Applicable |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 40 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D40ABD
$278,99
-$8.37 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 40 A, Full Load Current - Resistive 60 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$278.99
You must be logged in to post a review.
Reviews
There are no reviews yet.