Discount -3%

IEC Magnetic Contactor, 3 Poles, 24 V AC, 9 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D09B7

$111,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$111.99
Final shipping and tax calculated in checkout
Subtotal: $108.63 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D09B7
Availability: Ships in 1 days
SKU: GRG0948586 Category:
Full Load Amps-Inductive9 A
ItemIEC Magnetic Contactor
ActionNon-Reversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts24 V AC
ReversingNo
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 230V1
Height3.03 in
HP @ 1 Phase - 240V1 hp
HP @ 3 Phase - 208V2 hp
Width1.77 in
HP @ 3 Phase - 240V2 hp
Depth3.38 in
HP @ 3 Phase - 575V7 1/2 hp
HP @ 3 Phase - 480V5 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Auxiliary Contact Form1NO/1NC
SeriesTeSys Deca
NEMA SizeNot Applicable
Includes Protective CoverYes
Thermal Amperage25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Max. Operating Watts2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Tightening Torque1.7 Nm
Fire RatingUL 94 V1
Rated Breaking Capacity250 A @ 440V
Rated Voltage690V AC, 300V DC
Impulse Withstand Voltage6 kV
Rated Short-Time Withstand Current105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V), 2 Mcycles (9 A, AC-3e, Less than 440 V)
Overvoltage CategoryCAT III
Non-Overlap Time1.5 ms
ApplicationMotor Control, Resistive Load
Impedance2.5 mOhm
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts600/690V
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Mechanical Durability15 Mcycles
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Signalling Circuit Frequency25 to 400 Hz
Operating Speed3600 cycles per hr
Fuse Amps10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
IP RatingIP20
Inrush VA70 VA
Mounts OnPlate, Rail
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Working HeightUp to 9842.52 ft
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Electrical ConnectionScrew Clamp Terminals
Switching Current5 mA (Signalling Circuit)
Switching Voltage17 V (Signalling Circuit)
FeaturesWithout Built-In Suppressor Module
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Net Weight0.32 kg
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Watts Loss2 to 3W
Max. Temperature850°C
Horsepower @ Three Phase - 600V AC7 1/2 hp
Horsepower @ Three Phase - 240V AC2 hp
Mounting StyleDIN Rail, Plate
Includes Auxiliary ContactsYes
Horsepower @ Three Phase - 480V AC5 hp
Horsepower @ Three Phase - 208V AC2 hp
NEMA Enclosure RatingNo Enclosure
Reversing CapabilityNon-Reversing
Overall Depth3.39 in
Maximum Operating Temperature140 Degrees F
Overall Height3.03 in
Resistance PropertiesFire Resistant, Insulation Resistant
Embedded Surge SuppressorNo
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Single Phase - 120V AC1/3 hp
Minimum Operating Temperature-40 Degrees F
PhaseThree
NEMA Enclosure MaterialNot Applicable
Horsepower @ Single Phase - 240V AC1 hp
Overall Width1.77 in
Electrical Operating Durability2,000,000, 600,000
Number of Auxillary Contacts2
Maximum Voltage Rating690V AC
Contactor StyleIEC
Coil Voltage24V AC
Full Load Current - Resistive20 A
Mechanical Operating Durability15,000,000
Frequency50/60 Hz
Full Load Current - Inductive9 A
Number of Normally Open Main Contacts3
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Maximum Horse Power Rating1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Protective CoverWith
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Flame RetardanceV1 conforming to UL 94
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Mounting SupportRail, Plate
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Pole Contact Composition3 NO
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Motor Power KW2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3), 5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3), 2.2 kW at 400 V AC 50/60 Hz (AC-4), 2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 5.5 kW at 500 V AC 50/60 Hz (AC-3e), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Compatibility CodeLC1D
Minimum Switching Voltage17 V for signalling circuit
Connections - TerminalsPower circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end
Pollution Degree3
Rated Impulse Withstand Voltage6 kV IEC 60947
Conventional Free Air Thermal Current25 A (at 140°F (60°C)) for power circuit, 10 A (at 140°F (60°C)) for signalling circuit
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 20 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Product CertificationsGL, CSA, GOST, RINA, LROS (Lloyds register of shipping), UL, DNV, BV, CCC, UKCA
Contact CompatibilityM2
Heat Dissipation2 to 3 W at 50/60 Hz
Product Or Component TypeContactor
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Fire Resistance1562°F (850°C) IEC 60695-2-1
Control Circuit TypeAC 50/60 Hz standard
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Control Circuit Voltage24 V AC 50/60 Hz
Rated Short Time Withstand Current105 A 104°F (40°C) - 10 s for power circuit, 210 A 104°F (40°C) - 1 s for power circuit, 30 A 104°F (40°C) - 10 min for power circuit, 61 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
IRMS Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Protective TreatmentTHIEC 60068-2-30
IP Degree Of ProtectionIP20 front face IEC 60529
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Poles Description3P
Auxiliary Contact Composition1 NO + 1 NC
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Minimum Switching Current5 mA for signalling circuit
Contactor ApplicationResistive load, Motor control
Power Dissipation Per Pole1.56 W AC-1, 0.2 W AC-3, 0.2 W AC-3e
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#9 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D09B7
#SCHNEIDER ELECTRIC
#GRG0948586
#mfr:LC1D09B7
#part number:LC1D09B7
#pn:LC1D09B7
#part code:LC1D09B7
#item number:LC1D09B7
#product code:LC1D09B7
#manufacturer number:LC1D09B7
#manufacturers part number:LC1D09B7
#mfn:LC1D09B7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!