Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 115 A |
Full Load Amps-Resistive | 200 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 240 V AC |
Reversing | No |
Height | 4.33 in |
Width | 4.33 in |
HP @ 3 Phase - 208V | 30 hp |
HP @ 3 Phase - 575V | 100 hp |
Depth | 5.12 in |
HP @ 3 Phase - 240V | 40 hp |
HP @ 3 Phase - 480V | 75 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Auxiliary Contact Form | 1NO/1NC |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
Max. Temperature | 850°C |
Mechanical Durability | 8 Mcycles |
Operating Speed | 2400 cycles per hr |
Thermal Amperage | 200 A (at 60°C Power Circuit) |
Inrush VA | 280 to 350 VA |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Electrical Connection | Screw Clamp Terminals |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Hold VA | 2 to 18 VA |
Fire Rating | UL 94 V1 |
Switching Current | 5 mA (Signalling Circuit) |
Impedance | 0.6 mOhm |
Operating Time | 6 to 20 ms (Opening), 20 to 50 ms (Closing) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz) |
Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Electrical Durability | 0.8 Mcycles (200 A, AC-1, Less than 440 V), 0.95 Mcycles (115 A, AC-3, Less than 440 V), 0.95 Mcycles (115 A, AC-3e, Less than 440 V) |
Rated Voltage | 1000V AC, 300V DC |
Net Weight | 2.5 kg |
Overvoltage Category | CAT III |
IP Rating | IP20 |
Rated Breaking Capacity | 1100 A @ 440V |
Max. Operating Watts | 30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e) |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Includes Protective Cover | Yes |
Watts Loss | 3 to 8W |
Working Height | Up to 9842.52 ft |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Application | Motor Control, Resistive Load |
Switching Voltage | 17 V (Signalling Circuit) |
Fuse Amps | 250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit) |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Making Capacity | 1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Mounts On | Plate, Rail |
Impulse Withstand Voltage | 8 kV |
Non-Overlap Time | 1.5 ms |
Horsepower @ Three Phase - 600V AC | 100 hp |
Horsepower @ Single Phase - 240V AC | 2 hp |
Mechanical Operating Durability | 8,000,000 |
Number of Normally Open Main Contacts | 3 |
Mounting Style | DIN Rail, Plate |
Number of Auxillary Contacts | 2 |
Coil Voltage | 240V AC |
NEMA Enclosure Rating | No Enclosure |
Maximum Voltage Rating | 1000V AC |
Embedded Surge Suppressor | Yes |
Phase | Three |
Resistance Properties | Fire Resistant, Insulation Resistant |
Horsepower @ Three Phase - 240V AC | 40 hp |
Frequency | 50/60 Hz |
Contactor Style | IEC |
Reversing Capability | Non-Reversing |
Maximum Operating Temperature | 140 Degrees F |
NEMA Enclosure Material | Not Applicable |
Electrical Operating Durability | 800,000, 950,000 |
Overall Width | 0.47 in |
Horsepower @ Three Phase - 208V AC | 30 hp |
Full Load Current - Resistive | 200 A |
Horsepower @ Three Phase - 480V AC | 75 hp |
Minimum Operating Temperature | -40 Degrees F |
Full Load Current - Inductive | 115 A |
Overall Depth | 5.35 in |
Includes Auxiliary Contacts | Yes |
Terminal Connection Type | Screw Clamp Terminals |
Overall Height | 6.22 in |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 240 V AC, 115 A, Reversing: No, SCHNEIDER, Mfr# LC1D115U7
$504.39
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 115 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$504.39
You must be logged in to post a review.
Reviews