Full Load Amps-Inductive | 9 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 25 A |
Number of Poles | 3 |
Coil Volts | 110 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 5/16 hp |
HP @ 1 Phase - 240V | 1 hp |
Height | 1.97 in |
HP @ 3 Phase - 208V | 2 hp |
Width | 3.62 in |
HP @ 3 Phase - 240V | 2 hp |
HP @ 3 Phase - 575V | 7 1/2 hp |
Depth | 4.41 in |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 5 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO/1NC |
Series | TeSys Deca |
Frame / Series / Class / Code | TeSys |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Mounts On | Plate, Rail |
Fuse Amps | 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit) |
Inrush VA | 70 VA |
Features | Without Built-In Suppressor Module |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Watts Loss | 2 to 3W |
Application | Motor Control, Resistive Load |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Mechanical Durability | 15 Mcycles |
Operating Speed | 3600 cycles per hr |
Switching Voltage | 17 V (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Rated Insulation Volts | 600/690V |
Impedance | 2.5 mOhm |
Net Weight | 0.32 kg |
Electrical Durability | 0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V), 2 Mcycles (9 A, AC-3e, Less than 440 V) |
Tightening Torque | 1.7 Nm |
Thermal Amperage | 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Max. Temperature | 850°C |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Rated Breaking Capacity | 250 A @ 440V |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Signalling Circuit Frequency | 25 to 400 Hz |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Working Height | Up to 9842.52 ft |
Fire Rating | UL 94 V1 |
Includes Protective Cover | Yes |
Impulse Withstand Voltage | 6 kV |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Overvoltage Category | CAT III |
Switching Current | 5 mA (Signalling Circuit) |
Electrical Connection | Screw Clamp Terminals |
Rated Voltage | 690V AC, 300V DC |
IP Rating | IP20 |
Includes Auxiliary Contacts | Yes |
Mechanical Operating Durability | 15,000,000 |
Full Load Current - Inductive | 9 A |
Embedded Surge Suppressor | No |
Maximum Operating Temperature | 140 Degrees F |
Mounting Style | DIN Rail, Plate |
NEMA Enclosure Material | Not Applicable |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 208V AC | 2 hp |
Horsepower @ Single Phase - 240V AC | 1 hp |
Minimum Operating Temperature | -40 Degrees F |
Overall Height | 3.03 in |
NEMA Enclosure Rating | No Enclosure |
Number of Auxillary Contacts | 2 |
Coil Voltage | 110V AC |
Reversing Capability | Non-Reversing |
Horsepower @ Single Phase - 120V AC | 1/3 hp |
Overall Width | 1.77 in |
Contactor Style | IEC |
Full Load Current - Resistive | 25 A |
Phase | Three |
Horsepower @ Three Phase - 240V AC | 2 hp |
Resistance Properties | Fire Resistant, Insulation Resistant |
Maximum Voltage Rating | 690V AC |
Electrical Operating Durability | 2,000,000, 600,000 |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 480V AC | 5 hp |
Overall Depth | 3.39 in |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 110 V AC, 9 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D09F7
$119,99
-100% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 25 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$119.99
You must be logged in to post a review.