Full Load Amps-Inductive | 12 A |
Item | IEC Magnetic Contactor |
Action | Reversing |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 24 V AC |
Reversing | Yes |
Height | 2.28 in |
Width | 3.54 in |
Depth | 2.24 in |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | None |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO |
Series | TeSys K |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Signalling Circuit Frequency | Less Than 400 Hz |
Max. Operating Watts | 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz) |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Hold VA | 4.5 VA |
Working Height | 6561.68 ft |
Rated Making Capacity | 144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit) |
IP Rating | IP20 |
Rated Insulation Volts | 600/690V |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Operating Speed | 3600 cycles per hr |
Application | Motor Control, Resistive Load |
Net Weight | 0.39 kg |
Watts Loss | 1.3W |
Overvoltage Category | CAT III |
Mechanical Durability | 5 Mcycles |
Features | Preassembled with Reversing Power Busbar |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Rated Short-Time Withstand Current | 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit) |
Impedance | 3 mOhm |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Voltage | 690V AC |
Inrush VA | 30 VA |
Impulse Withstand Voltage | 8 kV |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Mounts On | Plate, Rail |
Switching Current | 5 mA (Signalling Circuit) |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Rated Breaking Capacity | 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Electrical Durability | 0.3 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (12 A, AC-3, Less than 440 V), 1.3 Mcycles (12 A, AC-3e, Less than 440 V) |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Tightening Torque | 0.8 to 1.3 Nm |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Electrical Connection | Screw Clamp Terminals |
Overall Width | 3.54 in |
Number of Auxillary Contacts | 1 |
Terminal Connection Type | Screw Clamp Terminals |
Reversing Capability | Reversing |
Contactor Style | IEC |
Embedded Surge Suppressor | No |
Resistance Properties | Insulation Resistant |
Full Load Current - Inductive | 12 A |
Minimum Operating Temperature | -13 Degrees F |
Coil Voltage | 24V AC |
NEMA Enclosure Material | Not Applicable |
Overall Depth | 2.24 in |
NEMA Enclosure Rating | No Enclosure |
Electrical Operating Durability | 1,300,000, 300,000 |
Frequency | 50/60 Hz |
Mounting Style | DIN Rail, Plate |
Maximum Operating Temperature | 122 Degrees F |
Number of Normally Open Main Contacts | 3 |
Mechanical Operating Durability | 5,000,000 |
Maximum Voltage Rating | 690V AC |
Overall Height | 2.28 in |
Includes Auxiliary Contacts | Yes |
Full Load Current - Resistive | 20 A |
Rated Operational Voltage | Power circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz |
Minimum Switching Current | 5 mA for signalling circuit |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Motor Power KW | 3 kW 220 to 230 V AC 50/60 Hz, 5.5 kW 380 to 415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz, 4 kW 690 V AC 50/60 Hz |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Interlocking Type | Mechanical |
Control Circuit Type | AC 50/60 Hz |
Device Application | Control |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Product Or Component Type | Reversing contactor |
Minimum Switching Voltage | 17 V for signalling circuit |
Protective Treatment | TC IEC 60068, TC DIN 50016 |
Rated Short Time Withstand Current | 115 A 122°F (50°C) - 1 s for power circuit, 105 A 122°F (50°C) - 5 s for power circuit, 100 A 122°F (50°C) - 10 s for power circuit, 75 A 122°F (50°C) - 30 s for power circuit, 55 A 122°F (50°C) - 1 min for power circuit, 50 A 122°F (50°C) - 3 min for power circuit, 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Utilisation Category | AC-3, AC-3e, AC-4, AC-1 |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 |
Heat Dissipation | 1.3 W |
Auxiliary Contact Composition | 1 NO |
Operating Altitude | 6561.68 ft (2000 m) without derating |
IP Degree Of Protection | IP20 VDE 0106 |
Contactor Application | Resistive load, Motor control |
Maximum Operating Rate | 3600 cyc/h |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Rated Operational Current | 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
Auxiliary Contacts Type | Instantaneous 1 NO |
Control Circuit Voltage | 24 V AC 50/60 Hz |
Power Pole Contact Composition | 3 NO |
Mounting Support | Plate, Rail |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end |
Poles Description | 3P |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
IRMS Rated Making Capacity | 144 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Non Overlap Distance | 0.02 in (0.5 mm) |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
Hold-In Power Consumption in VA | 4.5 VA (at 68°F (20°C)) |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Ambient Air Temperature For Operation | -13 to 122°F (-25 to 50°C) |
Inrush Power in VA | 30 VA (at 68°F (20°C)) |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V AC, 12 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K1210B7
$203,99
-$6.12 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC, Maximum Voltage Rating 690V AC
9999 in stock
Must order in multiples of 1
Subtotal:
$203.99
You must be logged in to post a review.
Reviews
There are no reviews yet.