Discount -3%

IEC Magnetic Contactor, 3 Poles, 24 V AC, 12 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K1210B7

$203,99
-$6.12 / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC, Maximum Voltage Rating 690V AC

9999 in stock

Must order in multiples of 1
Subtotal:
$203.99
Final shipping and tax calculated in checkout
Subtotal: $197.87 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2K1210B7
Availability: Ships in 1 days
SKU: GRG0478366 Category:
Full Load Amps-Inductive12 A
ItemIEC Magnetic Contactor
ActionReversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts24 V AC
ReversingYes
Height2.28 in
Width3.54 in
Depth2.24 in
Enclosure NEMA RatingNo Enclosure
Aux. Contact ConfigurationNone
Hz50/60
Frame / Series / Class / CodeTeSys
NEMA SizeNot Applicable
Auxiliary Contact Form1NO
SeriesTeSys K
StandardsBS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Signalling Circuit FrequencyLess Than 400 Hz
Max. Operating Watts4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz)
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Hold VA4.5 VA
Working Height6561.68 ft
Rated Making Capacity144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit)
IP RatingIP20
Rated Insulation Volts600/690V
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Operating Speed3600 cycles per hr
ApplicationMotor Control, Resistive Load
Net Weight0.39 kg
Watts Loss1.3W
Overvoltage CategoryCAT III
Mechanical Durability5 Mcycles
FeaturesPreassembled with Reversing Power Busbar
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Rated Short-Time Withstand Current115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Impedance3 mOhm
Switching Voltage17 V (Signalling Circuit)
Rated Voltage690V AC
Inrush VA30 VA
Impulse Withstand Voltage8 kV
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Mounts OnPlate, Rail
Switching Current5 mA (Signalling Circuit)
Operating Time10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Rated Breaking Capacity110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Shock Resistance10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Electrical Durability0.3 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (12 A, AC-3, Less than 440 V), 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Tightening Torque0.8 to 1.3 Nm
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Electrical ConnectionScrew Clamp Terminals
Overall Width3.54 in
Number of Auxillary Contacts1
Terminal Connection TypeScrew Clamp Terminals
Reversing CapabilityReversing
Contactor StyleIEC
Embedded Surge SuppressorNo
Resistance PropertiesInsulation Resistant
Full Load Current - Inductive12 A
Minimum Operating Temperature-13 Degrees F
Coil Voltage24V AC
NEMA Enclosure MaterialNot Applicable
Overall Depth2.24 in
NEMA Enclosure RatingNo Enclosure
Electrical Operating Durability1,300,000, 300,000
Frequency50/60 Hz
Mounting StyleDIN Rail, Plate
Maximum Operating Temperature122 Degrees F
Number of Normally Open Main Contacts3
Mechanical Operating Durability5,000,000
Maximum Voltage Rating690V AC
Overall Height2.28 in
Includes Auxiliary ContactsYes
Full Load Current - Resistive20 A
Rated Operational VoltagePower circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Minimum Switching Current5 mA for signalling circuit
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Motor Power KW3 kW 220 to 230 V AC 50/60 Hz, 5.5 kW 380 to 415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz, 4 kW 690 V AC 50/60 Hz
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Interlocking TypeMechanical
Control Circuit TypeAC 50/60 Hz
Device ApplicationControl
Mechanical RobustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
Product Or Component TypeReversing contactor
Minimum Switching Voltage17 V for signalling circuit
Protective TreatmentTC IEC 60068, TC DIN 50016
Rated Short Time Withstand Current115 A 122°F (50°C) - 1 s for power circuit, 105 A 122°F (50°C) - 5 s for power circuit, 100 A 122°F (50°C) - 10 s for power circuit, 75 A 122°F (50°C) - 30 s for power circuit, 55 A 122°F (50°C) - 1 min for power circuit, 50 A 122°F (50°C) - 3 min for power circuit, 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Utilisation CategoryAC-3, AC-3e, AC-4, AC-1
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
Heat Dissipation1.3 W
Auxiliary Contact Composition1 NO
Operating Altitude6561.68 ft (2000 m) without derating
IP Degree Of ProtectionIP20 VDE 0106
Contactor ApplicationResistive load, Motor control
Maximum Operating Rate3600 cyc/h
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Rated Operational Current12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Auxiliary Contacts TypeInstantaneous 1 NO
Control Circuit Voltage24 V AC 50/60 Hz
Power Pole Contact Composition3 NO
Mounting SupportPlate, Rail
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Poles Description3P
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
IRMS Rated Making Capacity144 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Non Overlap Distance0.02 in (0.5 mm)
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
Hold-In Power Consumption in VA4.5 VA (at 68°F (20°C))
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Inrush Power in VA30 VA (at 68°F (20°C))
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#12 A
#Reversing: Yes
#SCHNEIDER ELECTRIC
#Mfr LC2K1210B7
#SCHNEIDER ELECTRIC
#GRG0478366
#mfr:LC2K1210B7
#part number:LC2K1210B7
#pn:LC2K1210B7
#part code:LC2K1210B7
#item number:LC2K1210B7
#product code:LC2K1210B7
#manufacturer number:LC2K1210B7
#manufacturers part number:LC2K1210B7
#mfn:LC2K1210B7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!