Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 32 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 50 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
HP @ 1 Phase - 230V | 5 |
HP @ 1 Phase - 120V | 2 hp |
HP @ 1 Phase - 240V | 5 hp |
Height | 3.36 in |
Width | 1.77 in |
HP @ 3 Phase - 208V | 10 hp |
Depth | 3.62 in |
HP @ 3 Phase - 240V | 10 hp |
HP @ 3 Phase - 575V | 30 hp |
HP @ 3 Phase - 480V | 20 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Max. Temperature | 850°C |
Rated Short-Time Withstand Current | 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Electrical Connection | Screw Clamp Terminals |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Control Circuit Voltage Limits | Drop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C) |
Operating Speed | 3600 cycles per hr |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit) |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
Net Weight | 0.535 kg |
IP Rating | IP20 |
Signalling Circuit Frequency | 25 to 400 Hz |
Mounts On | Plate, Rail |
Overvoltage Category | CAT III |
Max. Operating Watts | 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Rated Voltage | 690V AC, 300V DC |
Non-Overlap Time | 1.5 ms |
Electrical Durability | 1.65 Mcycles (32 A, AC-3, Less than 440 V), 1.4 Mcycles (50 A, AC-1, Less than 440 V), 1.65 Mcycles (32 A, AC-3e, Less than 440 V) |
Impedance | 2 mOhm |
Switching Voltage | 17 V (Signalling Circuit) |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Rated Breaking Capacity | 550 A @ 440V |
Impulse Withstand Voltage | 6 kV |
Operating Time | 53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit) |
Includes Protective Cover | Yes |
Mechanical Durability | 30 Mcycles |
Working Height | Up to 9842.52 ft |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit) |
Rated Insulation Volts | 600/690V |
Application | Motor Control, Resistive Load |
Fire Rating | UL 94 V1 |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Overall Width | 1.77 in |
NEMA Enclosure Material | Not Applicable |
Embedded Surge Suppressor | Yes |
Coil Voltage | 24V DC |
Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
Minimum Operating Temperature | -40 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Overall Depth | 3.98 in |
Terminal Connection Type | Screw Clamp Terminals |
Phase | Three |
Full Load Current - Resistive | 50 A |
Mechanical Operating Durability | 30,000,000 |
Full Load Current - Inductive | 32 A |
Horsepower @ Single Phase - 240V AC | 5 hp |
Number of Auxillary Contacts | 2 |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 600V AC | 30 hp |
Includes Auxiliary Contacts | Yes |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Three Phase - 240V AC | 10 hp |
Mounting Style | DIN Rail, Plate |
Electrical Operating Durability | 1,400,000, 1,650,000 |
Horsepower @ Three Phase - 480V AC | 20 hp |
Overall Height | 3.35 in |
Horsepower @ Single Phase - 120V AC | 2 hp |
Contactor Style | IEC |
Maximum Voltage Rating | 690V AC |
Reversing Capability | Non-Reversing |
Maximum Operating Temperature | 140 Degrees F |
Resistance Properties | Fire Resistant, Insulation Resistant |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 63 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Hold-In Power Consumption in W | 5.4 W 68°F (20°C) |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 50 A (at 140°F (60°C)) for power circuit |
Pollution Degree | 3 |
Product Or Component Type | Contactor |
Contactor Application | Resistive load, Motor control |
Maximum Horse Power Rating | 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Power Dissipation Per Pole | 2 W AC-3, 5 W AC-1, 2 W AC-3e |
Auxiliary Contact Composition | 1 NO + 1 NC |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Product Certifications | DNV, GL, CCC, UL, GOST, BV, LROS (Lloyds register of shipping), RINA, CSA, UKCA |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Pole Contact Composition | 3 NO |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms) |
Protective Cover | With |
Mounting Support | Rail, Plate |
Control Circuit Type | DC standard |
Contact Compatibility | M4 |
Minimum Switching Voltage | 17 V for signalling circuit |
Average Impedance | 2 mOhm - Ith 50 A 50 Hz for power circuit |
Minimum Switching Current | 5 mA for signalling circuit |
Inrush Power in W | 5.4 W 68°F (20°C)) |
Rated Operational Current | 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Rated Short Time Withstand Current | 260 A 104°F (40°C) - 10 s for power circuit, 430 A 104°F (40°C) - 1 s for power circuit, 60 A 104°F (40°C) - 10 min for power circuit, 138 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Protective Treatment | THIEC 60068-2-30 |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end |
Motor Power KW | 7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 15 kW at 380 to 400 V AC 50/60 Hz (AC-3), 15 kW at 415 to 440 V AC 50/60 Hz (AC-3), 18.5 kW at 500 V AC 50/60 Hz (AC-3), 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3), 7.5 kW at 400 V AC 50/60 Hz (AC-4), 7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 15 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 15 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 18.5 kW at 500 V AC 50/60 Hz (AC-3e), 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947 |
IP Degree Of Protection | IP20 front face IEC 60529 |
Flame Retardance | V1 conforming to UL 94 |
Compatibility Code | LC1D |
Poles Description | 3P |
Time Constant | 28 ms |
Utilisation Category | AC-3, AC-1, AC-4, AC-3e |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 32 A, Reversing: No, SCHNEIDER, Mfr# LC1D32BD
$225,99
-$6.78 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 32 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$225.99
You must be logged in to post a review.