Discount -3%

IEC Magnetic Contactor, 3 Poles, 24 V DC, 32 A, Reversing: No, SCHNEIDER, Mfr# LC1D32BD

$225,99
-$6.78 / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 32 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$225.99
Final shipping and tax calculated in checkout
Subtotal: $219.21 with subscription
Brand Name: SCHNEIDER
Mfr #: LC1D32BD
Availability: Ships in 1 days
SKU: GRG2582027 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive32 A
ActionNon-Reversing
Full Load Amps-Resistive50 A
Number of Poles3
Coil Volts24 V DC
ReversingNo
HP @ 1 Phase - 230V5
HP @ 1 Phase - 120V2 hp
HP @ 1 Phase - 240V5 hp
Height3.36 in
Width1.77 in
HP @ 3 Phase - 208V10 hp
Depth3.62 in
HP @ 3 Phase - 240V10 hp
HP @ 3 Phase - 575V30 hp
HP @ 3 Phase - 480V20 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
SeriesTeSys Deca
NEMA SizeNot Applicable
Max. Temperature850°C
Rated Short-Time Withstand Current260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical ConnectionScrew Clamp Terminals
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Control Circuit Voltage LimitsDrop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
Operating Speed3600 cycles per hr
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Net Weight0.535 kg
IP RatingIP20
Signalling Circuit Frequency25 to 400 Hz
Mounts OnPlate, Rail
Overvoltage CategoryCAT III
Max. Operating Watts7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Rated Voltage690V AC, 300V DC
Non-Overlap Time1.5 ms
Electrical Durability1.65 Mcycles (32 A, AC-3, Less than 440 V), 1.4 Mcycles (50 A, AC-1, Less than 440 V), 1.65 Mcycles (32 A, AC-3e, Less than 440 V)
Impedance2 mOhm
Switching Voltage17 V (Signalling Circuit)
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor
Rated Breaking Capacity550 A @ 440V
Impulse Withstand Voltage6 kV
Operating Time53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening)
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Includes Protective CoverYes
Mechanical Durability30 Mcycles
Working HeightUp to 9842.52 ft
Thermal Amperage10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)
Rated Insulation Volts600/690V
ApplicationMotor Control, Resistive Load
Fire RatingUL 94 V1
Environmental AttributesMercury Free, PVC Free, Pollution Degree 3
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Overall Width1.77 in
NEMA Enclosure MaterialNot Applicable
Embedded Surge SuppressorYes
Coil Voltage24V DC
Horsepower @ Three Phase - 208V AC7 1/2 hp
Minimum Operating Temperature-40 Degrees F
NEMA Enclosure RatingNo Enclosure
Overall Depth3.98 in
Terminal Connection TypeScrew Clamp Terminals
PhaseThree
Full Load Current - Resistive50 A
Mechanical Operating Durability30,000,000
Full Load Current - Inductive32 A
Horsepower @ Single Phase - 240V AC5 hp
Number of Auxillary Contacts2
Frequency50/60 Hz
Horsepower @ Three Phase - 600V AC30 hp
Includes Auxiliary ContactsYes
Number of Normally Open Main Contacts3
Horsepower @ Three Phase - 240V AC10 hp
Mounting StyleDIN Rail, Plate
Electrical Operating Durability1,400,000, 1,650,000
Horsepower @ Three Phase - 480V AC20 hp
Overall Height3.35 in
Horsepower @ Single Phase - 120V AC2 hp
Contactor StyleIEC
Maximum Voltage Rating690V AC
Reversing CapabilityNon-Reversing
Maximum Operating Temperature140 Degrees F
Resistance PropertiesFire Resistant, Insulation Resistant
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 63 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Fire Resistance1562°F (850°C) IEC 60695-2-1
Rated Impulse Withstand Voltage6 kV IEC 60947
Hold-In Power Consumption in W5.4 W 68°F (20°C)
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 50 A (at 140°F (60°C)) for power circuit
Pollution Degree3
Product Or Component TypeContactor
Contactor ApplicationResistive load, Motor control
Maximum Horse Power Rating2 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
Power Dissipation Per Pole2 W AC-3, 5 W AC-1, 2 W AC-3e
Auxiliary Contact Composition1 NO + 1 NC
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Product CertificationsDNV, GL, CCC, UL, GOST, BV, LROS (Lloyds register of shipping), RINA, CSA, UKCA
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Pole Contact Composition3 NO
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms)
Protective CoverWith
Mounting SupportRail, Plate
Control Circuit TypeDC standard
Contact CompatibilityM4
Minimum Switching Voltage17 V for signalling circuit
Average Impedance2 mOhm - Ith 50 A 50 Hz for power circuit
Minimum Switching Current5 mA for signalling circuit
Inrush Power in W5.4 W 68°F (20°C))
Rated Operational Current32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Rated Short Time Withstand Current260 A 104°F (40°C) - 10 s for power circuit, 430 A 104°F (40°C) - 1 s for power circuit, 60 A 104°F (40°C) - 10 min for power circuit, 138 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protective TreatmentTHIEC 60068-2-30
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end
Motor Power KW7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 15 kW at 380 to 400 V AC 50/60 Hz (AC-3), 15 kW at 415 to 440 V AC 50/60 Hz (AC-3), 18.5 kW at 500 V AC 50/60 Hz (AC-3), 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3), 7.5 kW at 400 V AC 50/60 Hz (AC-4), 7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 15 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 15 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 18.5 kW at 500 V AC 50/60 Hz (AC-3e), 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
IP Degree Of ProtectionIP20 front face IEC 60529
Flame RetardanceV1 conforming to UL 94
Compatibility CodeLC1D
Poles Description3P
Time Constant28 ms
Utilisation CategoryAC-3, AC-1, AC-4, AC-3e
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V DC
#32 A
#Reversing: No
#SCHNEIDER
#Mfr LC1D32BD
#SCHNEIDER
#GRG2582027
#mfr:LC1D32BD
#part number:LC1D32BD
#pn:LC1D32BD
#part code:LC1D32BD
#item number:LC1D32BD
#product code:LC1D32BD
#manufacturer number:LC1D32BD
#manufacturers part number:LC1D32BD
#mfn:LC1D32BD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!