Discount -3%

IEC Magnetic Contactor, 3 Poles, 110 V AC, 25 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D25F7

$186,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$186.99
Final shipping and tax calculated in checkout
Subtotal: $181.38 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D25F7
Availability: Ships in 1 days
SKU: GRG0569269 Category:
Full Load Amps-Inductive25 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive40 A
Number of Poles3
Coil Volts110 V AC
ReversingNo
HP @ 1 Phase - 120V2 hp
Height3.35 in
HP @ 1 Phase - 240V3 hp
Width1.77 in
HP @ 3 Phase - 208V7 1/2 hp
HP @ 3 Phase - 575V20 hp
Depth3.62 in
HP @ 3 Phase - 240V7 1/2 hp
HP @ 3 Phase - 480V15 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / CodeTeSys
SeriesTeSys Deca
NEMA SizeNot Applicable
Auxiliary Contact Form1NO/1NC
Impedance2 mOhm
Signalling Circuit Frequency25 to 400 Hz
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Electrical ConnectionScrew Clamp Terminals
ApplicationMotor Control, Resistive Load
Working HeightUp to 9842.52 ft
Rated Insulation Volts600/690V
Rated Voltage690V AC, 300V DC
Switching Voltage17 V (Signalling Circuit)
Max. Operating Watts5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Mounts OnPlate, Rail
Includes Protective CoverYes
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Impulse Withstand Voltage6 kV
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Thermal Amperage10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)
Rated Breaking Capacity450 A @ 440V
Switching Current5 mA (Signalling Circuit)
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Watts Loss2 to 3W
IP RatingIP20
Non-Overlap Time1.5 ms
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
FeaturesWithout Built-In Suppressor Module
Mechanical Durability15 Mcycles
Overvoltage CategoryCAT III
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Net Weight0.37 kg
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Max. Temperature850°C
Fire RatingUL 94 V1
Operating Speed3600 cycles per hr
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Electrical Durability1.65 Mcycles (25 A, AC-3, Less than 440 V), 1.4 Mcycles (40 A, AC-1, Less than 440 V), 1.65 Mcycles (25 A, AC-3e, Less than 440 V)
Rated Short-Time Withstand Current240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Inrush VA70 VA
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Embedded Surge SuppressorNo
Terminal Connection TypeScrew Clamp Terminals
Overall Height3.35 in
Resistance PropertiesFire Resistant, Insulation Resistant
Horsepower @ Three Phase - 240V AC7 1/2 hp
Horsepower @ Three Phase - 480V AC15 hp
Contactor StyleIEC
Overall Depth3.62 in
Overall Width1.77 in
Maximum Operating Temperature140 Degrees F
Horsepower @ Three Phase - 600V AC20 hp
Mounting StyleDIN Rail, Plate
Coil Voltage110V AC
Reversing CapabilityNon-Reversing
Number of Auxillary Contacts2
Minimum Operating Temperature-40 Degrees F
Number of Normally Open Main Contacts3
Horsepower @ Single Phase - 120V AC2 hp
Full Load Current - Inductive25 A
NEMA Enclosure MaterialNot Applicable
Frequency50/60 Hz
Horsepower @ Single Phase - 240V AC3 hp
Horsepower @ Three Phase - 208V AC7 1/2 hp
Full Load Current - Resistive40 A
PhaseThree
NEMA Enclosure RatingNo Enclosure
Includes Auxiliary ContactsYes
Electrical Operating Durability1,400,000, 1,650,000
Mechanical Operating Durability15,000,000
Maximum Voltage Rating690V AC
Contact CompatibilityM2
Average Impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Contactor ApplicationResistive load, Motor control
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end
Product CertificationsUL, BV, RINA, CCC, GL, GOST, DNV, LROS (Lloyds register of shipping), CSA, UKCA
Minimum Switching Voltage17 V for signalling circuit
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Control Circuit TypeAC 50/60 Hz standard
Auxiliary Contact Composition1 NO + 1 NC
Mounting SupportPlate, Rail
Flame RetardanceV1 conforming to UL 94
Pole Contact Composition3 NO
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Pollution Degree3
Maximum Horse Power Rating3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
Utilisation CategoryAC-3, AC-4, AC-1, AC-3e
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Power Dissipation Per Pole3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e
Fire Resistance1562°F (850°C) IEC 60695-2-1
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
Protective CoverWith
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Control Circuit Voltage110 V AC 50/60 Hz
Poles Description3P
Protective TreatmentTHIEC 60068-2-30
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Compatibility CodeLC1D
Minimum Switching Current5 mA for signalling circuit
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Rated Impulse Withstand Voltage6 kV IEC 60947
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Rated Operational Current25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Heat Dissipation2 to 3 W at 50/60 Hz
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms)
Product Or Component TypeContactor
IP Degree Of ProtectionIP20 front face IEC 60529
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Motor Power KW5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit
Rated Short Time Withstand Current240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#110 V AC
#25 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D25F7
#SCHNEIDER ELECTRIC
#GRG0569269
#mfr:LC1D25F7
#part number:LC1D25F7
#pn:LC1D25F7
#part code:LC1D25F7
#item number:LC1D25F7
#product code:LC1D25F7
#manufacturer number:LC1D25F7
#manufacturers part number:LC1D25F7
#mfn:LC1D25F7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!