Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 32 A |
Full Load Amps-Resistive | 50 A |
Number of Poles | 3 |
Coil Volts | 110 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 2 hp |
Height | 3.35 in |
HP @ 1 Phase - 240V | 5 hp |
HP @ 3 Phase - 208V | 7 1/2 hp |
Width | 1.77 in |
HP @ 3 Phase - 240V | 10 hp |
HP @ 3 Phase - 575V | 30 hp |
Depth | 3.62 in |
HP @ 3 Phase - 480V | 20 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Series | TeSys Deca |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO/1NC |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Non-Overlap Time | 1.5 ms |
Rated Breaking Capacity | 550 A @ 440V |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Max. Operating Watts | 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Signalling Circuit Frequency | 25 to 400 Hz |
Net Weight | 0.375 kg |
Rated Insulation Volts | 600/690V |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Working Height | Up to 9842.52 ft |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Watts Loss | 2 to 3W |
Switching Voltage | 17 V (Signalling Circuit) |
Impedance | 2 mOhm |
Operating Speed | 3600 cycles per hr |
Impulse Withstand Voltage | 6 kV |
IP Rating | IP20 |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
Features | Without Built-In Suppressor Module |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit) |
Fire Rating | UL 94 V1 |
Overvoltage Category | CAT III |
Electrical Connection | Screw Clamp Terminals |
Electrical Durability | 1.65 Mcycles (32 A, AC-3, Less than 440 V), 1.4 Mcycles (50 A, AC-1, Less than 440 V), 1.65 Mcycles (32 A, AC-3e, Less than 440 V) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Rated Voltage | 690V AC, 300V DC |
Includes Protective Cover | Yes |
Rated Short-Time Withstand Current | 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit) |
Inrush VA | 70 VA |
Application | Motor Control, Resistive Load |
Max. Temperature | 850°C |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Mounts On | Plate, Rail |
Switching Current | 5 mA (Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit) |
Mechanical Durability | 15 Mcycles |
Number of Auxillary Contacts | 2 |
Number of Normally Open Main Contacts | 3 |
Mounting Style | DIN Rail, Plate |
Contactor Style | IEC |
Full Load Current - Resistive | 50 A |
Reversing Capability | Non-Reversing |
Overall Height | 3.35 in |
Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
Horsepower @ Three Phase - 480V AC | 20 hp |
Embedded Surge Suppressor | No |
Resistance Properties | Fire Resistant, Insulation Resistant |
Includes Auxiliary Contacts | Yes |
Frequency | 50/60 Hz |
Coil Voltage | 110V AC |
Horsepower @ Single Phase - 240V AC | 5 hp |
Phase | Three |
Horsepower @ Three Phase - 240V AC | 10 hp |
Overall Depth | 3.62 in |
Maximum Voltage Rating | 690V AC |
Minimum Operating Temperature | -40 Degrees F |
Terminal Connection Type | Screw Clamp Terminals |
NEMA Enclosure Rating | No Enclosure |
Overall Width | 1.77 in |
Maximum Operating Temperature | 140 Degrees F |
Horsepower @ Single Phase - 120V AC | 2 hp |
NEMA Enclosure Material | Not Applicable |
Mechanical Operating Durability | 15,000,000 |
Horsepower @ Three Phase - 600V AC | 30 hp |
Full Load Current - Inductive | 32 A |
Electrical Operating Durability | 1,400,000, 1,650,000 |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 110 V AC, 32 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D32F7
$214,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 32 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$214.99