Full Load Amps-Inductive | 12 A |
Item | Miniature IEC Magnetic Contactor |
Action | Reversing |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 24 V AC |
Reversing | Yes |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 120V | 1/2 hp |
Height | 3.54 in |
HP @ 1 Phase - 240V | 1 1/2 hp |
Width | 3.54 in |
Depth | 2.24 in |
HP @ 3 Phase - 575V | 10 hp |
HP @ 3 Phase - 240V | 3 hp |
HP @ 3 Phase - 480V | 7 1/2 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NC |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
NEMA Size | Not Applicable |
Series | TeSys K |
Electrical Connection | Screw Clamp Terminals |
Application | Motor Control, Resistive Load |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Inrush VA | 30 VA |
Impedance | 3 mOhm |
Operating Speed | 3600 cycles per hr |
Signalling Circuit Frequency | Less Than 400 Hz |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
IP Rating | IP20 |
Max. Operating Watts | 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz) |
Net Weight | 0.39 kg |
Electrical Durability | 0.3 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (12 A, AC-3, Less than 440 V), 1.3 Mcycles (12 A, AC-3e, Less than 440 V) |
Rated Short-Time Withstand Current | 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Impulse Withstand Voltage | 8 kV |
Rated Breaking Capacity | 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V |
Mechanical Durability | 5 Mcycles |
Tightening Torque | 0.8 to 1.3 Nm |
Watts Loss | 1.3W |
Rated Voltage | 690V AC |
Working Height | 6561.68 ft |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Insulation Volts | 600/690V |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Overvoltage Category | CAT III |
Features | Preassembled with Reversing Power Busbar |
Rated Making Capacity | 144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit) |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Hold VA | 4.5 VA |
Mounts On | Plate, Rail |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Electrical Operating Durability | 1,300,000, 300,000 |
Overall Depth | 2.24 in |
Terminal Connection Type | Screw Clamp Terminals |
Maximum Operating Temperature | 122 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
Frequency | 50/60 Hz |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Mechanical Operating Durability | 5,000,000 |
Coil Voltage | 24V AC |
Reversing Capability | Reversing |
Horsepower @ Three Phase - 240V AC | 3 hp |
Overall Width | 3.54 in |
Contactor Style | IEC |
Mounting Style | DIN Rail, Plate |
Number of Auxillary Contacts | 1 |
Overall Height | 2.28 in |
Includes Auxiliary Contacts | Yes |
Full Load Current - Inductive | 12 A |
NEMA Enclosure Material | Not Applicable |
Horsepower @ Three Phase - 480V AC | 7 1/2 hp |
Minimum Operating Temperature | -13 Degrees F |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 600V AC | 10 hp |
Full Load Current - Resistive | 20 A |
Number of Normally Open Main Contacts | 3 |
Maximum Voltage Rating | 690V AC |
Resistance Properties | Insulation Resistant |
Ambient Air Temperature For Operation | -13 to 122°F (-25 to 50°C) |
Product Or Component Type | Reversing contactor |
Auxiliary Contact Composition | 1 NC |
IP Degree Of Protection | IP20 VDE 0106 |
Minimum Switching Voltage | 17 V for signalling circuit |
Protective Treatment | TC IEC 60068, TC DIN 50016 |
Rated Operational Voltage | Power circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz |
Contactor Application | Resistive load, Motor control |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Control Circuit Type | AC 50/60 Hz |
Utilisation Category | AC-3, AC-3e, AC-4, AC-1 |
Inrush Power in VA | 30 VA (at 68°F (20°C)) |
Device Application | Control |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Interlocking Type | Mechanical |
Rated Operational Current | 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
IRMS Rated Making Capacity | 144 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Hold-In Power Consumption in VA | 4.5 VA (at 68°F (20°C)) |
Auxiliary Contacts Type | Instantaneous 1 NC |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Non Overlap Distance | 0.02 in (0.5 mm) |
Maximum Operating Rate | 3600 cyc/h |
Poles Description | 3P |
Mounting Support | Plate, Rail |
Control Circuit Voltage | 24 V AC 50/60 Hz |
Minimum Switching Current | 5 mA for signalling circuit |
Motor Power KW | 3 kW 220 to 230 V AC 50/60 Hz, 5.5 kW 380 to 415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz, 4 kW 690 V AC 50/60 Hz |
Rated Short Time Withstand Current | 115 A 122°F (50°C) - 1 s for power circuit, 105 A 122°F (50°C) - 5 s for power circuit, 100 A 122°F (50°C) - 10 s for power circuit, 75 A 122°F (50°C) - 30 s for power circuit, 55 A 122°F (50°C) - 1 min for power circuit, 50 A 122°F (50°C) - 3 min for power circuit, 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Power Pole Contact Composition | 3 NO |
Heat Dissipation | 1.3 W |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 24 V AC, 12 A, Reversing: Yes, SCHNEIDER, Mfr# LC2K1201B7
$213,99
-$6.42 / ea
with subscription
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$213.99
You must be logged in to post a review.
Reviews
There are no reviews yet.