IEC Magnetic Contactor, Auxiliary Contact Form Auxiliary Contacts Not Included, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 4, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 0, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$89.89
Final shipping and tax calculated in checkout
Subtotal: $87.19 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1K09008F7
Availability: Ships in 1 days
SKU: GRG0478348 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive9 A
Full Load Amps-Resistive20 A
Number of Poles4
Coil Volts110 V AC
ReversingNo
Height2.28 in
Width1.77 in
Depth2.24 in
Enclosure NEMA RatingNo Enclosure
Aux. Contact ConfigurationNone
Hz50/60
StandardsBS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
SeriesTeSys K
Auxiliary Contact FormAuxiliary Contacts Not Included
NEMA SizeNot Applicable
Frame / Series / Class / CodeTeSys
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Rated Short-Time Withstand Current90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit)
Watts Loss1.3W
Impedance3 mOhm
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Tightening Torque0.8 to 1.3 Nm
Mechanical Durability10 Mcycles
Shock Resistance10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
ApplicationResistive Load
Operating Time10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing), 15 to 25 ms (Coil De-Energisation and NC Closing), 5 to 15 ms (Coil Energisation and NC Opening)
Impulse Withstand Voltage8 kV
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Working Height6561.68 ft
Net Weight0.18 kg
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Signalling Circuit FrequencyLess Than 400 Hz
Fuse Amps25 A
Mounts OnPlate, Rail
IP RatingIP22
Overvoltage CategoryCAT III
Thermal Amperage20 A (at 50°C Power Circuit)
Rated Making Capacity110 A (AC Power Circuit)
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
Electrical ConnectionScrew Clamp Terminals
Inrush VA30 VA
Operating Speed3600 cycles per hr
Hold VA4.5 VA
Rated Insulation Volts600/690V
Rated Voltage690V AC
Electrical Durability0.18 Mcycles (20 A, AC-1, Less than 440 V)
Frequency50/60 Hz
Terminal Connection TypeScrew Clamp Terminals
Full Load Current - Inductive9 A
Mechanical Operating Durability10,000,000
Embedded Surge SuppressorNo
Number of Normally Closed Main Contacts2
Maximum Voltage Rating690V AC
Overall Depth2.24 in
Contactor StyleIEC
Full Load Current - Resistive20 A
Number of Normally Open Main Contacts2
Includes Auxiliary ContactsNo
Overall Height2.28 in
Coil Voltage110V AC
Overall Width1.77 in
Reversing CapabilityNon-Reversing
NEMA Enclosure MaterialNot Applicable
NEMA Enclosure RatingNo Enclosure
Electrical Operating Durability180,000
Number of Auxillary Contacts0
Mounting StyleDIN Rail, Plate
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
Mounting SupportRail, Plate
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Rated Operational Current20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Control Circuit TypeAC 50/60 Hz
Hold-In Power Consumption in VA4.5 VA (at 68°F (20°C))
Poles Description4P
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
IRMS Rated Making Capacity110 A AC for power circuit conforming to IEC 60947
Device ApplicationControl
Heat Dissipation1.3 W
Maximum Operating Rate3600 cyc/h
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit
Inrush Power in VA30 VA (at 68°F (20°C))
Mechanical RobustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Operating Altitude6561.68 ft (2000 m) without derating
Product Or Component TypeContactor
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA C22.2 No 14
Protective TreatmentTC IEC 60068, TC DIN 50016
Utilisation CategoryAC-1
IP Degree Of ProtectionIP2X VDE 0106
Control Circuit Voltage110 V AC 50/60 Hz
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Power Pole Contact Composition2 NO + 2 NC
Rated Short Time Withstand Current90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#4 Poles
#110 V AC
#9 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1K09008F7
#SCHNEIDER ELECTRIC
#GRG0478348
#mfr:LC1K09008F7
#part number:LC1K09008F7
#pn:LC1K09008F7
#part code:LC1K09008F7
#item number:LC1K09008F7
#product code:LC1K09008F7
#manufacturer number:LC1K09008F7
#manufacturers part number:LC1K09008F7
#mfn:LC1K09008F7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!