Item
IEC Magnetic Contactor
Full Load Amps-Inductive
80 A
Aux. Contact Configuration
1NO/1NC
Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, UL, DNV, BV, CCC, CSA, LROS, GL, RINA, GOST, THIEC 60068-2-30
Includes
Everlink Power Connections
Application
Resistive Load
Features
Without Built-In Suppressor Module
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
Rated Breaking Capacity
1000 A @ 440V
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz) , Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 60 Hz)
Rated Short-Time Withstand Current
520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Working Height
Up to 9842.52 ft
Fuse Amps
10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Thermal Amperage
10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Electrical Connection
Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors
Impulse Withstand Voltage
6 kV
Switching Current
5 mA (Signalling Circuit)
Switching Voltage
17 V (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Voltage
690V AC, 300V DC
Mechanical Durability
6 Mcycles
Electrical Durability
1.4 Mcycles (80 A, AC-1, Less than 440 V)
Operating Speed
3600 cycles per hr
Includes Protective Cover
Yes
Overvoltage Category
CAT III
Operating Time
4 to 19 ms (Opening), 12 to 26 ms (Closing)
Rated Insulation Volts
600/690V
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Signalling Circuit Frequency
25 to 400 Hz
Insulation Resistance
u003e 10 MOhm for signalling circuit
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at u003c= 690 V coordination type 1 for power circuit, 125 A gG at u003c= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Permissible Ambient Air Temperature Around The Device
-40-60°C, 60-70°C with derating
Protective Treatment
THIEC 60068-2-30
[Ith] Conventional Free Air Thermal Current
10 A (at 60°C) for signalling circuit, 80 A (at 60°C) for power circuit
Flame Retardance
V1 conforming to UL 94
Pole Contact Composition
4 NO
Range of Product
TeSys Deca
Inrush Power In Va
140-140 VA 60 Hz cos phi 0.75 (at 20°C)
Maximum Operating Rate
3600 cyc/h 60°C
[Icw] Rated Short-Time Withstand Current
640 A 40°C - 10 s for power circuit, 900 A 40°C - 1 s for power circuit, 110 A 40°C - 10 min for power circuit, 260 A 40°C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Operating Altitude
0...9842.52 ft (0...3000 m)
Fire Resistance
850°C IEC 60695-2-1
Control Circuit Type
AC 60 Hz
Product or Component Type
contactor
[Ui] Rated Insulation Voltage
power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 690 V IEC 60947-4-1
Minimum Switching Current
5 mA for signalling circuit
Heat Dissipation
4-5 W at 60 Hz
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1000 A at 440 V for power circuit conforming to IEC 60947
[Ie] Rated Operational Current
80 A (at u003c60°C) at u003c= 440 V AC AC-1 for power circuit
Climatic Withstand
IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Hold-In Power Consumption In Va
13-13 VA 60 Hz cos phi 0.3 (at 20°C)
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) , vibrations contactor closed 4 Gn, 5...300 Hz) , shocks contactor closed 15 Gn for 11 ms) , shocks contactor open 10 Gn for 11 ms)
Connections - Terminals
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible without cable end, power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible without cable end, power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible with cable end, power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible with cable end, power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: solid without cable end, power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: solid without cable end
Ip Degree of Protection
IP20 front face IEC 60529
Average Impedance
1.6 mOhm - Ith 80 A 50 Hz for power circuit
Mounting Support
plate, rail
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition
1 NO + 1 NC
Power Dissipation Per Pole
10.2 W AC-1
[Ue] Rated Operational Voltage
power circuit u003c= 690 V AC 25...400 Hz, power circuit u003c= 300 V DC
Minimum Switching Voltage
17 V for signalling circuit
[Uc] Control Circuit Voltage
120 V AC 60 Hz
Country of Origin (subject to change)
Indonesia