IEC Magnetic Contactor, 3 Poles, 220 V AC, 115 A, SCHNEIDER ELECTRIC, Mfr# LC1D115M7

$519,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor

9999 in stock

Must order in multiples of 1
Subtotal:
$519.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D115M7
Availability: Ships in 5 days
SKU: GRG0849786 Category:
Full Load Amps-Inductive115 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive200 A
Number of Poles3
Coil Volts220 V AC
Height158 mm
HP @ 3 Phase - 208V30 hp
Width120 mm
HP @ 3 Phase - 575V100 hp
Depth136 mm
HP @ 3 Phase - 240V40 hp
HP @ 3 Phase - 480V75 hp
Aux. Contact Configuration1NO/1NC
SeriesLC1D
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, RINA, CSA, CCC, BV, LROS, GL, GOST, DNV, UL, UKCA, THIEC 60068-2-30
Operating Time6 to 20 ms (Opening), 20 to 50 ms (Closing)
Inrush VA280 to 350 VA
IP RatingIP20
Shock Resistance15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Impedance0.6 mOhm
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Tightening Torque1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Net Weight2.5 kg
Rated Insulation Volts600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Max. Temperature850°C
Impulse Withstand Voltage8 kV
Environmental AttributesMercury Free, PVC Free, Pollution Degree 3
Max. Operating Watts30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
Electrical ConnectionScrew Clamp Terminals
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Mounts OnPlate, Rail
Fire RatingUL 94 V1
Rated Short-Time Withstand Current250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Non-Overlap Time1.5 ms
Switching Voltage17 V (Signalling Circuit)
Rated Breaking Capacity1100 A @ 440V
Operating Speed2400 cycles per hr
Signalling Circuit Frequency25 to 400 Hz
Switching Current5 mA (Signalling Circuit)
Thermal Amperage200 A (at 60°C Power Circuit)
Rated Voltage1000V AC, 300V DC
ApplicationMotor Control, Resistive Load
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor
Includes Protective CoverYes
Overvoltage CategoryCAT III
Hold VA2 to 18 VA
Mechanical Durability8 Mcycles
Fuse Amps250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Watts Loss3 to 8W
Rated Making Capacity1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Working HeightUp to 9842.52 ft
Electrical Durability0.8 Mcycles (200 A, AC-1, Less than 440 V), 0.95 Mcycles (115 A, AC-3, Less than 440 V), 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption in VA2 to 18 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 2 to 18 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Fire Resistance1562°F (850°C) IEC 60695-2-1
Maximum Horse Power Rating30 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Product CertificationsRINA, CSA, CCC, BV, LROS (Lloyds register of shipping), GL, GOST, DNV, UL, UKCA
Auxiliary Contact Composition1 NO + 1 NC
Rated Operational Current200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Flame RetardanceV1 conforming to UL 94
Heat Dissipation3 to 8 W at 50/60 Hz
Pollution Degree3
IP Degree Of ProtectionIP20 front face IEC 60529
Contact CompatibilityM13
Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 6 Gn for 11 ms)
Associated Fuse Rating250 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 200 A gG at Less than or Equal to 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Maximum Operating Rate2400 cyc/h 140°F (60°C)
Contactor ApplicationMotor control, Resistive load
Inrush Power in VA280 to 350 VA 60 Hz cos phi 0.8 (at 68°F (20°C)), 280 to 350 VA 50 Hz cos phi 0.8 (at 68°F (20°C))
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Power circuit 1000 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Pole Contact Composition3 NO
Rated Impulse Withstand Voltage8 kV IEC 60947
Power Dissipation Per Pole24 W AC-1, 7.9 W AC-3, 7.9 W AC-3e
Rated Operational VoltagePower circuit Less than or Equal to 1000 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Mounting SupportRail, Plate
Minimum Switching Current5 mA for signalling circuit
Control Circuit TypeAC 50/60 Hz standard
Motor Power KW30 kW at 220 to 230 V AC 50/60 Hz (AC-3), 55 kW at 380 to 400 V AC 50/60 Hz (AC-3), 59 kW at 415 to 440 V AC 50/60 Hz (AC-3), 75 kW at 500 V AC 50/60 Hz (AC-3), 80 kW at 660 to 690 V AC 50/60 Hz (AC-3), 65 kW at 1000 V AC 50/60 Hz (AC-3), 18.5 kW at 400 V AC 50/60 Hz (AC-4), 30 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 55 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 59 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 660 to 690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e)
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: solid without cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: solid without cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: solid without cable end
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Control Circuit Voltage220 V AC 50/60 Hz
IRMS Rated Making Capacity1260 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Product Or Component TypeContactor
Protective TreatmentTHIEC 60068-2-30
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Poles Description3P
Rated Short Time Withstand Current250 A 104°F (40°C) - 10 min for power circuit, 550 A 104°F (40°C) - 1 min for power circuit, 950 A 104°F (40°C) - 10 s for power circuit, 1100 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Average Impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
Conventional Free Air Thermal Current200 A (at 140°F (60°C)) for power circuit
Protective CoverWith
Safety Reliability LevelB10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Country of Origin (subject to change)Czechia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#220 V AC
#115 A
#SCHNEIDER ELECTRIC
#Mfr LC1D115M7
#SCHNEIDER ELECTRIC
#GRG0849786
#mfr:LC1D115M7
#part number:LC1D115M7
#pn:LC1D115M7
#part code:LC1D115M7
#item number:LC1D115M7
#product code:LC1D115M7
#manufacturer number:LC1D115M7
#manufacturers part number:LC1D115M7
#mfn:LC1D115M7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!