Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Full Load Amps-Resistive | 25 A |
Number of Poles | 3 |
Coil Volts | 220 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 5/16 hp |
HP @ 1 Phase - 240V | 1 hp |
Height | 3.03 in |
HP @ 3 Phase - 208V | 2 hp |
Width | 1.77 in |
HP @ 3 Phase - 240V | 2 hp |
HP @ 3 Phase - 575V | 7 1/2 hp |
Depth | 3.39 in |
HP @ 3 Phase - 480V | 5 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Series | TeSys Deca |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
NEMA Size | Not Applicable |
Switching Current | 5 mA (Signalling Circuit) |
Thermal Amperage | 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Impulse Withstand Voltage | 6 kV |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Rated Voltage | 690V AC, 300V DC |
Fire Rating | UL 94 V1 |
Features | Without Built-In Suppressor Module |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Mounts On | Plate, Rail |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Inrush VA | 70 VA |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Electrical Connection | Screw Clamp Terminals |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Impedance | 2.5 mOhm |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Working Height | Up to 9842.52 ft |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Mechanical Durability | 15 Mcycles |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Overvoltage Category | CAT III |
Electrical Durability | 0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V), 2 Mcycles (9 A, AC-3e, Less than 440 V) |
Operating Speed | 3600 cycles per hr |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Rated Breaking Capacity | 250 A @ 440V |
Watts Loss | 2 to 3W |
Rated Insulation Volts | 600/690V |
Signalling Circuit Frequency | 25 to 400 Hz |
Application | Motor Control, Resistive Load |
Tightening Torque | 1.7 Nm |
Net Weight | 0.32 kg |
IP Rating | IP20 |
Switching Voltage | 17 V (Signalling Circuit) |
Max. Temperature | 850°C |
Includes Protective Cover | Yes |
Fuse Amps | 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit) |
Overall Depth | 3.39 in |
NEMA Enclosure Material | Not Applicable |
Electrical Operating Durability | 2,000,000, 600,000 |
Full Load Current - Inductive | 9 A |
Overall Width | 1.77 in |
Horsepower @ Three Phase - 480V AC | 5 hp |
Mechanical Operating Durability | 15,000,000 |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Maximum Operating Temperature | 140 Degrees F |
Number of Auxillary Contacts | 2 |
Mounting Style | DIN Rail, Plate |
Full Load Current - Resistive | 25 A |
Coil Voltage | 220V AC |
Number of Normally Open Main Contacts | 3 |
Contactor Style | IEC |
Phase | Three |
Overall Height | 3.03 in |
Minimum Operating Temperature | -40 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Single Phase - 120V AC | 1/3 hp |
Frequency | 50/60 Hz |
Embedded Surge Suppressor | No |
Horsepower @ Single Phase - 240V AC | 1 hp |
Terminal Connection Type | Screw Clamp Terminals |
Reversing Capability | Non-Reversing |
Horsepower @ Three Phase - 240V AC | 2 hp |
Maximum Voltage Rating | 690V AC |
Horsepower @ Three Phase - 208V AC | 2 hp |
Includes Auxiliary Contacts | Yes |
Resistance Properties | Fire Resistant, Insulation Resistant |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 220 V AC, 9 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D09M7
$124,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 220V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 25 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1