Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Full Load Amps-Resistive | 20 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 240 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 1 |
HP @ 1 Phase - 120V | 1/2 hp |
Height | 3.03 in |
HP @ 1 Phase - 240V | 1 hp |
Width | 1.77 in |
HP @ 3 Phase - 208V | 2 hp |
Depth | 3.38 in |
HP @ 3 Phase - 575V | 7 1/2 hp |
HP @ 3 Phase - 240V | 2 hp |
HP @ 3 Phase - 480V | 5 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NO/1NC |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Mechanical Durability | 15 Mcycles |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Fuse Amps | 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit) |
Rated Insulation Volts | 600/690V |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Electrical Durability | 0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V), 2 Mcycles (9 A, AC-3e, Less than 440 V) |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Overvoltage Category | CAT III |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Inrush VA | 70 VA |
Operating Speed | 3600 cycles per hr |
IP Rating | IP20 |
Watts Loss | 2 to 3W |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Electrical Connection | Screw Clamp Terminals |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Includes Protective Cover | Yes |
Working Height | Up to 9842.52 ft |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Signalling Circuit Frequency | 25 to 400 Hz |
Features | Without Built-In Suppressor Module |
Fire Rating | UL 94 V1 |
Impulse Withstand Voltage | 6 kV |
Switching Current | 5 mA (Signalling Circuit) |
Max. Temperature | 850°C |
Rated Voltage | 690V AC, 300V DC |
Thermal Amperage | 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Mounts On | Plate, Rail |
Application | Motor Control, Resistive Load |
Impedance | 2.5 mOhm |
Net Weight | 0.32 kg |
Tightening Torque | 1.7 Nm |
Non-Overlap Time | 1.5 ms |
Rated Breaking Capacity | 250 A @ 440V |
Horsepower @ Single Phase - 240V AC | 1 hp |
Contactor Style | IEC |
Overall Depth | 3.39 in |
Mechanical Operating Durability | 15,000,000 |
NEMA Enclosure Material | Not Applicable |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 240V AC | 2 hp |
Overall Height | 3.03 in |
Coil Voltage | 240V AC |
Horsepower @ Single Phase - 120V AC | 1/3 hp |
Full Load Current - Resistive | 20 A |
Overall Width | 1.77 in |
Horsepower @ Three Phase - 480V AC | 5 hp |
Full Load Current - Inductive | 9 A |
Includes Auxiliary Contacts | Yes |
Electrical Operating Durability | 2,000,000, 600,000 |
Number of Normally Open Main Contacts | 3 |
Maximum Operating Temperature | 140 Degrees F |
Minimum Operating Temperature | -40 Degrees F |
Resistance Properties | Fire Resistant, Insulation Resistant |
Phase | Three |
Frequency | 50/60 Hz |
Number of Auxillary Contacts | 2 |
Reversing Capability | Non-Reversing |
NEMA Enclosure Rating | No Enclosure |
Maximum Voltage Rating | 690V AC |
Horsepower @ Three Phase - 208V AC | 2 hp |
Mounting Style | DIN Rail, Plate |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 240 V AC, 9 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D09U7
$118,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$118.99
You must be logged in to post a review.
Reviews