Full Load Amps-Inductive | 12 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 16 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
HP @ 1 Phase - 120V | 1/2 hp |
Height | 3.9 in |
HP @ 1 Phase - 240V | 2 hp |
HP @ 3 Phase - 208V | 3 hp |
Width | 1.77 in |
Depth | 3.74 in |
HP @ 3 Phase - 240V | 3 hp |
HP @ 3 Phase - 575V | 10 hp |
HP @ 3 Phase - 480V | 7 1/2 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Series | TeSys Deca |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Signalling Circuit Frequency | 25 to 400 Hz |
Fuse Amps | 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit) |
Rated Insulation Volts | 600/690V |
Non-Overlap Time | 1.5 ms |
Rated Voltage | 690V AC, 300V DC |
Working Height | Up to 9842.52 ft |
Impulse Withstand Voltage | 6 kV |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Mechanical Durability | 30 Mcycles |
Operating Time | 53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening) |
Max. Temperature | 850°C |
Mounts On | Plate, Rail |
Overvoltage Category | CAT III |
Impedance | 2.5 mOhm |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Max. Operating Watts | 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3), 7.5 kW (at 500V AC 50/60 Hz AC-3), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 3.7 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3e), 7.5 kW (at 500V AC 50/60 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 16 A (at 60°C Power Circuit) |
Application | Motor Control, Resistive Load |
Electrical Durability | 2 Mcycles (12 A, AC-3, Less than 440 V), 0.8 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (12 A, AC-3e, Less than 440 V) |
Switching Voltage | 17 V (Signalling Circuit) |
Control Circuit Voltage Limits | Drop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C) |
Operating Speed | 3600 cycles per hr |
Electrical Connection | Spring Terminals |
Net Weight | 0.485 kg |
Includes Protective Cover | Yes |
Rated Breaking Capacity | 250 A @ 440V |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
IP Rating | IP20 |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Fire Rating | UL 94 V1 |
Switching Current | 5 mA (Signalling Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Features | With Integral Suppression Device |
Full Load Current - Resistive | 16 A |
NEMA Enclosure Rating | No Enclosure |
Embedded Surge Suppressor | Yes |
Overall Height | 3.9 in |
Horsepower @ Single Phase - 240V AC | 2 hp |
Overall Width | 1.77 in |
Full Load Current - Inductive | 12 A |
Resistance Properties | Fire Resistant, Insulation Resistant |
Reversing Capability | Non-Reversing |
Horsepower @ Three Phase - 600V AC | 10 hp |
Horsepower @ Three Phase - 240V AC | 3 hp |
Contactor Style | IEC |
Coil Voltage | 24V DC |
Number of Auxillary Contacts | 2 |
Horsepower @ Three Phase - 208V AC | 3 hp |
Electrical Operating Durability | 2,000,000, 800,000 |
NEMA Enclosure Material | Not Applicable |
Maximum Operating Temperature | 140 Degrees F |
Horsepower @ Three Phase - 480V AC | 7 1/2 hp |
Mounting Style | DIN Rail, Plate |
Number of Normally Open Main Contacts | 3 |
Maximum Voltage Rating | 690V AC |
Includes Auxiliary Contacts | Yes |
Phase | Three |
Overall Depth | 3.74 in |
Frequency | 50/60 Hz |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Mechanical Operating Durability | 30,000,000 |
Terminal Connection Type | Spring Loaded Terminals |
Minimum Operating Temperature | -40 Degrees F |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 12 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D123BD
$195,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 16 A, Reversing Capability Non-Reversing, Overall Height 3.9 in, Overall Width 1.77 in, Terminal Connection Type Spring Loaded Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$195.99
You must be logged in to post a review.
Reviews
There are no reviews yet.