Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 18 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 32 A |
Number of Poles | 3 |
Coil Volts | 240 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 3 |
HP @ 1 Phase - 120V | 1 hp |
Height | 3.03 in |
HP @ 1 Phase - 240V | 3 hp |
Width | 1.77 in |
HP @ 3 Phase - 208V | 5 hp |
HP @ 3 Phase - 240V | 5 hp |
Depth | 3.38 in |
HP @ 3 Phase - 575V | 15 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 10 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Frame / Series / Class / Code | TeSys |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Impedance | 2.5 mOhm |
Rated Voltage | 690V AC, 300V DC |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
Impulse Withstand Voltage | 6 kV |
Working Height | Up to 9842.52 ft |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Includes Protective Cover | Yes |
Electrical Connection | Screw Clamp Terminals |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Max. Operating Watts | 4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Rated Insulation Volts | 600/690V |
Overvoltage Category | CAT III |
Tightening Torque | 1.7 Nm |
Watts Loss | 2 to 3W |
Inrush VA | 70 VA |
Rated Breaking Capacity | 300 A @ 440V |
Application | Motor Control, Resistive Load |
IP Rating | IP20 |
Rated Short-Time Withstand Current | 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
Fire Rating | UL 94 V1 |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Mechanical Durability | 15 Mcycles |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Switching Current | 5 mA (Signalling Circuit) |
Signalling Circuit Frequency | 25 to 400 Hz |
Mounts On | Plate, Rail |
Switching Voltage | 17 V (Signalling Circuit) |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Operating Speed | 3600 cycles per hr |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit) |
Features | Without Built-In Suppressor Module |
Max. Temperature | 850°C |
Electrical Durability | 1.65 Mcycles (18 A, AC-3, Less than 440 V), 1 Mcycles (32 A, AC-1, Less than 440 V), 1.65 Mcycles (18 A, AC-3e, Less than 440 V) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Net Weight | 0.33 kg |
Mounting Style | DIN Rail, Plate |
Horsepower @ Single Phase - 120V AC | 1 hp |
Overall Width | 1.77 in |
Maximum Operating Temperature | 140 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Three Phase - 208V AC | 5 hp |
Horsepower @ Single Phase - 240V AC | 3 hp |
Embedded Surge Suppressor | No |
Phase | Three |
Mechanical Operating Durability | 15,000,000 |
Includes Auxiliary Contacts | Yes |
Overall Depth | 3.39 in |
Terminal Connection Type | Screw Clamp Terminals |
Coil Voltage | 240V AC |
Minimum Operating Temperature | -40 Degrees F |
Resistance Properties | Fire Resistant, Insulation Resistant |
Full Load Current - Inductive | 18 A |
Horsepower @ Three Phase - 600V AC | 15 hp |
Number of Auxillary Contacts | 2 |
Frequency | 50/60 Hz |
Contactor Style | IEC |
Reversing Capability | Non-Reversing |
Horsepower @ Three Phase - 240V AC | 5 hp |
Horsepower @ Three Phase - 480V AC | 10 hp |
Electrical Operating Durability | 1,000,000, 1,650,000 |
Maximum Voltage Rating | 690V AC |
NEMA Enclosure Material | Not Applicable |
Overall Height | 3.03 in |
Control Circuit Type | AC 50/60 Hz |
Power Dissipation Per Pole | 2.5 W AC-1, 0.8 W AC-3, 0.8 W AC-3e |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 50 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 35 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Product Or Component Type | Contactor |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Compatibility Code | LC1D |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947 |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Flame Retardance | V1 conforming to UL 94 |
Rated Operational Current | 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Heat Dissipation | 2 to 3 W at 50/60 Hz |
Pole Contact Composition | 3 NO |
Mounting Support | Rail, Plate |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 32 A (at 140°F (60°C)) for power circuit |
Product Certifications | UL, DNV, RINA, GOST, LROS (Lloyds register of shipping), CCC, CSA, GL, BV, UKCA |
Poles Description | 3P |
Utilisation Category | AC-3, AC-1, AC-4, AC-3e |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms) |
Maximum Horse Power Rating | 1 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Contact Compatibility | M2 |
Control Circuit Voltage | 240 V AC 50/60 Hz |
Rated Short Time Withstand Current | 145 A 104°F (40°C) - 10 s for power circuit, 240 A 104°F (40°C) - 1 s for power circuit, 40 A 104°F (40°C) - 10 min for power circuit, 84 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Pollution Degree | 3 |
IP Degree Of Protection | IP20 front face IEC 60529 |
Motor Power KW | 4 kW at 220 to 230 V AC 50/60 Hz (AC-3), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3), 10 kW at 500 V AC 50/60 Hz (AC-3), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3), 4 kW at 400 V AC 50/60 Hz (AC-4), 4 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 10 kW at 500 V AC 50/60 Hz (AC-3e), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Average Impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
Contactor Application | Motor control, Resistive load |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Minimum Switching Voltage | 17 V for signalling circuit |
Protective Treatment | THIEC 60068-2-30 |
Protective Cover | With |
Minimum Switching Current | 5 mA for signalling circuit |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 240 V AC, 18 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D18U7
$195,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp
9999 in stock
Must order in multiples of 1
Subtotal:
$195.99
You must be logged in to post a review.
Reviews
There are no reviews yet.