IEC Magnetic Contactor, 3 Poles, 240 V AC, 18 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D18U7

$195,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp

9999 in stock

Must order in multiples of 1
Subtotal:
$195.99
Final shipping and tax calculated in checkout
Subtotal: $190.11 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D18U7
Availability: Ships in 1 days
SKU: GRG0533653 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive18 A
ActionNon-Reversing
Full Load Amps-Resistive32 A
Number of Poles3
Coil Volts240 V AC
ReversingNo
HP @ 1 Phase - 230V3
HP @ 1 Phase - 120V1 hp
Height3.03 in
HP @ 1 Phase - 240V3 hp
Width1.77 in
HP @ 3 Phase - 208V5 hp
HP @ 3 Phase - 240V5 hp
Depth3.38 in
HP @ 3 Phase - 575V15 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V10 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / CodeTeSys
SeriesTeSys Deca
NEMA SizeNot Applicable
Impedance2.5 mOhm
Rated Voltage690V AC, 300V DC
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Impulse Withstand Voltage6 kV
Working HeightUp to 9842.52 ft
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Includes Protective CoverYes
Electrical ConnectionScrew Clamp Terminals
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Max. Operating Watts4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Rated Insulation Volts600/690V
Overvoltage CategoryCAT III
Tightening Torque1.7 Nm
Watts Loss2 to 3W
Inrush VA70 VA
Rated Breaking Capacity300 A @ 440V
ApplicationMotor Control, Resistive Load
IP RatingIP20
Rated Short-Time Withstand Current145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Fuse Amps10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Fire RatingUL 94 V1
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Mechanical Durability15 Mcycles
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Non-Overlap Time1.5 ms
Switching Current5 mA (Signalling Circuit)
Signalling Circuit Frequency25 to 400 Hz
Mounts OnPlate, Rail
Switching Voltage17 V (Signalling Circuit)
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Operating Speed3600 cycles per hr
Thermal Amperage10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit)
FeaturesWithout Built-In Suppressor Module
Max. Temperature850°C
Electrical Durability1.65 Mcycles (18 A, AC-3, Less than 440 V), 1 Mcycles (32 A, AC-1, Less than 440 V), 1.65 Mcycles (18 A, AC-3e, Less than 440 V)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Net Weight0.33 kg
Mounting StyleDIN Rail, Plate
Horsepower @ Single Phase - 120V AC1 hp
Overall Width1.77 in
Maximum Operating Temperature140 Degrees F
NEMA Enclosure RatingNo Enclosure
Number of Normally Open Main Contacts3
Horsepower @ Three Phase - 208V AC5 hp
Horsepower @ Single Phase - 240V AC3 hp
Embedded Surge SuppressorNo
PhaseThree
Mechanical Operating Durability15,000,000
Includes Auxiliary ContactsYes
Overall Depth3.39 in
Terminal Connection TypeScrew Clamp Terminals
Coil Voltage240V AC
Minimum Operating Temperature-40 Degrees F
Resistance PropertiesFire Resistant, Insulation Resistant
Full Load Current - Inductive18 A
Horsepower @ Three Phase - 600V AC15 hp
Number of Auxillary Contacts2
Frequency50/60 Hz
Contactor StyleIEC
Reversing CapabilityNon-Reversing
Horsepower @ Three Phase - 240V AC5 hp
Horsepower @ Three Phase - 480V AC10 hp
Electrical Operating Durability1,000,000, 1,650,000
Maximum Voltage Rating690V AC
NEMA Enclosure MaterialNot Applicable
Overall Height3.03 in
Control Circuit TypeAC 50/60 Hz
Power Dissipation Per Pole2.5 W AC-1, 0.8 W AC-3, 0.8 W AC-3e
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 50 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 35 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Product Or Component TypeContactor
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Compatibility CodeLC1D
Fire Resistance1562°F (850°C) IEC 60695-2-1
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end
Rated Impulse Withstand Voltage6 kV IEC 60947
Flame RetardanceV1 conforming to UL 94
Rated Operational Current18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Heat Dissipation2 to 3 W at 50/60 Hz
Pole Contact Composition3 NO
Mounting SupportRail, Plate
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 32 A (at 140°F (60°C)) for power circuit
Product CertificationsUL, DNV, RINA, GOST, LROS (Lloyds register of shipping), CCC, CSA, GL, BV, UKCA
Poles Description3P
Utilisation CategoryAC-3, AC-1, AC-4, AC-3e
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Maximum Horse Power Rating1 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Contact CompatibilityM2
Control Circuit Voltage240 V AC 50/60 Hz
Rated Short Time Withstand Current145 A 104°F (40°C) - 10 s for power circuit, 240 A 104°F (40°C) - 1 s for power circuit, 40 A 104°F (40°C) - 10 min for power circuit, 84 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Auxiliary Contact Composition1 NO + 1 NC
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Pollution Degree3
IP Degree Of ProtectionIP20 front face IEC 60529
Motor Power KW4 kW at 220 to 230 V AC 50/60 Hz (AC-3), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3), 10 kW at 500 V AC 50/60 Hz (AC-3), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3), 4 kW at 400 V AC 50/60 Hz (AC-4), 4 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 10 kW at 500 V AC 50/60 Hz (AC-3e), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Average Impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
Contactor ApplicationMotor control, Resistive load
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Minimum Switching Voltage17 V for signalling circuit
Protective TreatmentTHIEC 60068-2-30
Protective CoverWith
Minimum Switching Current5 mA for signalling circuit
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#240 V AC
#18 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D18U7
#SCHNEIDER ELECTRIC
#GRG0533653
#mfr:LC1D18U7
#part number:LC1D18U7
#pn:LC1D18U7
#part code:LC1D18U7
#item number:LC1D18U7
#product code:LC1D18U7
#manufacturer number:LC1D18U7
#manufacturers part number:LC1D18U7
#mfn:LC1D18U7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!