Discount -3%

IEC Magnetic Contactor, 3 Poles, 24 V AC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D09B7

$297.78

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 2 hp

9999 in stock

Must order in multiples of 1
Subtotal:
$297.78
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2D09B7
Availability: Ships in 1 days
SKU: GRG4558224 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive9 A
ActionReversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts24 V AC
ReversingYes
HP @ 1 Phase - 230V1
HP @ 1 Phase - 120V1/2 hp
Height3.8 in
HP @ 1 Phase - 240V1 hp
HP @ 3 Phase - 208V2 hp
Width3.8 in
Depth5.3 in
HP @ 3 Phase - 240V2 hp
HP @ 3 Phase - 575V7 1/2 hp
HP @ 3 Phase - 480V5 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Auxiliary Contact Form1NO/1NC
IncludesElectrical Interlock
NEMA SizeNot Applicable
SeriesTeSys Deca
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Tightening Torque1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
Rated Breaking Capacity250 A @ 440V
Thermal Amperage10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Inrush VA70 VA
ApplicationMotor Control, Resistive Load
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Impulse Withstand Voltage6 kV
FeaturesWithout Built-In Suppressor Module, Preassembled with Reversing Power Busbar
Signalling Circuit Frequency25 to 400 Hz
Fuse Amps25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Rated Voltage690V AC, 300V DC
Mechanical Durability15 Mcycles
Includes Protective CoverYes
Fire RatingUL 94 V1
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Rated Short-Time Withstand Current30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Working HeightUp to 9842.52 ft
Electrical Durability0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V)
IP RatingIP20
Max. Temperature850°C
Net Weight0.687 kg
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Watts Loss2 to 3W
Operating Speed3600 cycles per hr
Max. Operating Watts2.2 kW (at 220 to 230V AC 50 Hz), 4 kW (at 380 to 400V AC 50 Hz), 4 kW (at 415 to 440V AC 50 Hz), 5.5 kW (at 500V AC 50 Hz), 5.5 kW (at 660 to 690V AC 50 Hz)
Rated Insulation Volts600/690V
Switching Voltage17 V (Signalling Circuit)
Impedance2.5 mOhm
Overvoltage CategoryCAT III
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Non-Overlap Time1.5 ms
Mounts OnPlate, Rail
Electrical ConnectionScrew Clamp Terminals
Switching Current5 mA (Signalling Circuit)
Resistance PropertiesFire Resistant, Insulation Resistant
Number of Auxillary Contacts2
NEMA Enclosure MaterialNot Applicable
Frequency50/60 Hz
Electrical Operating Durability2,000,000, 600,000
Maximum Operating Temperature140 Degrees F
Reversing CapabilityReversing
Horsepower @ Three Phase - 240V AC2 hp
Horsepower @ Single Phase - 120V AC1/2 hp
Horsepower @ Three Phase - 600V AC7 1/2 hp
Mechanical Operating Durability15,000,000
Maximum Voltage Rating690V AC
Coil Voltage24V AC
Contactor StyleIEC
Number of Normally Open Main Contacts3
Full Load Current - Resistive20 A
NEMA Enclosure RatingNo Enclosure
Minimum Operating Temperature-40 Degrees F
Horsepower @ Three Phase - 480V AC5 hp
Full Load Current - Inductive9 A
Overall Height3.03 in
Embedded Surge SuppressorNo
Phase3
Terminal Connection TypeScrew Clamp Terminals
Overall Depth3.39 in
Horsepower @ Single Phase - 240V AC1 hp
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 208V AC2 hp
Overall Width3.54 in
Includes Auxiliary ContactsYes
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#9 A
#Reversing: Yes
#SCHNEIDER ELECTRIC
#Mfr LC2D09B7
#SCHNEIDER ELECTRIC
#GRG4558224
#mfr:LC2D09B7
#part number:LC2D09B7
#pn:LC2D09B7
#part code:LC2D09B7
#item number:LC2D09B7
#product code:LC2D09B7
#manufacturer number:LC2D09B7
#manufacturers part number:LC2D09B7
#mfn:LC2D09B7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!