Discount -3%

IEC Magnetic Contactor, 3 Poles, 48 to 130 V AC/DC, 12 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D12EHE

$106,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 48-130V AC/DC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 25 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$106.99
Final shipping and tax calculated in checkout
Subtotal: $103.78 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D12EHE
Availability: Ships in 1 days
SKU: GRG6043751 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive12 A
Full Load Amps-Resistive25 A
Number of Poles3
Coil Volts48 to 130 V AC/DC
ReversingNo
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 240V2 hp
Height3.03 in
HP @ 3 Phase - 208V3 hp
Width1.77 in
Depth3.38 in
HP @ 3 Phase - 240V3 hp
HP @ 3 Phase - 575V10 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V7 1/2 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
NEMA SizeNot Applicable
Auxiliary Contact Form1NO/1NC
SeriesTeSys Deca
ApplicationMotor Control, Resistive Load
Signalling Circuit Frequency25 to 400 Hz
Control Circuit Voltage LimitsDrop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC/DC: 0.85 to 1.1 Uc (at -40 to 60°C), 1 to 1.1 Uc (at 60 to 70°C)
Watts Loss0.8W
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Electrical ConnectionScrew Clamp Terminals
Operating Speed3600 cycles per hr
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Overvoltage CategoryCAT III
Rated Short-Time Withstand Current100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit)
IP RatingIP20
Max. Temperature850°C
Switching Current5 mA (Signalling Circuit)
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Fuse Amps10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Impedance2.5 mOhm
Thermal Amperage10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Fire RatingUL 94 V1
Hold VA1.3 VA
Mounts OnPlate, Rail
Rated Insulation Volts690V
Max. Operating Watts3 kW (at 220 to 230V AC 50 Hz AC-3), 5.5 kW (at 380 to 400V AC 50 Hz AC-3), 5.5 kW (at 415V AC 50 Hz AC-3), 5.5 kW (at 440V AC 50 Hz AC-3), 7.5 kW (at 500V AC 50 Hz AC-3), 7.5 kW (at 660 to 690V AC 50 Hz AC-3), 3 kW (at 220 to 230V AC 50 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50 Hz AC-3e), 5.5 kW (at 415V AC 50 Hz AC-3e), 5.5 kW (at 440V AC 50 Hz AC-3e), 7.5 kW (at 500V AC 50 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50 Hz AC-3e)
Inrush VA25 VA
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Switching Voltage17 V (Signalling Circuit)
Operating Time45 to 55 ms (Closing), 20 to 90 ms (Opening)
Impulse Withstand Voltage6 kV
Mechanical Durability15 Mcycles
Includes Protective CoverYes
Net Weight0.373 kg
Working HeightUp to 9842.52 ft
Electrical Durability2.3 Mcycles (11 A, AC-3, Less than 440 V), 0.8 Mcycles (25 A, AC-1, Less than 440 V), 2.3 Mcycles (11 A, AC-3e, Less than 440 V)
FeaturesBuilt-In Bi-Directional Peak Limiting
Tightening Torque1.7 Nm
Environmental AttributesMercury Free, Pollution Degree 3
Non-Overlap Time1.5 ms
Rated Breaking Capacity250 A @ 440V
Rated Voltage690V AC
Number of Auxillary Contacts2
Overall Height3.03 in
Horsepower @ Three Phase - 240V AC3 hp
Full Load Current - Inductive12 A
Embedded Surge SuppressorNo
Horsepower @ Three Phase - 600V AC10 hp
Resistance PropertiesFire Resistant, Insulation Resistant
Terminal Connection TypeScrew Clamp Terminals
Full Load Current - Resistive25 A
Mounting StyleDIN Rail, Plate
Contactor StyleIEC
Minimum Operating Temperature-40 Degrees F
Includes Auxiliary ContactsYes
Horsepower @ Three Phase - 208V AC3 hp
NEMA Enclosure RatingNo Enclosure
Reversing CapabilityNon-Reversing
NEMA Enclosure MaterialNot Applicable
Number of Normally Open Main Contacts3
Overall Depth3.39 in
Electrical Operating Durability2,300,000, 800,000
Frequency50/60 Hz
Overall Width1.77 in
Maximum Operating Temperature140 Degrees F
PhaseThree
Horsepower @ Three Phase - 480V AC7 1/2 hp
Horsepower @ Single Phase - 240V AC2 hp
Coil Voltage48-130V AC/DC
Horsepower @ Single Phase - 120V AC1/2 hp
Maximum Voltage Rating690V AC
Mechanical Operating Durability15,000,000
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#48 to 130 V AC/DC
#12 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D12EHE
#SCHNEIDER ELECTRIC
#GRG6043751
#mfr:LC1D12EHE
#part number:LC1D12EHE
#pn:LC1D12EHE
#part code:LC1D12EHE
#item number:LC1D12EHE
#product code:LC1D12EHE
#manufacturer number:LC1D12EHE
#manufacturers part number:LC1D12EHE
#mfn:LC1D12EHE

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!