IEC Magnetic Contactor, 3 Poles, 100 to 250 V AC/DC, 38 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D38KUE

$267,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 100-250V AC/DC, Number of Poles 3, Full Load Current - Inductive 38 A, Full Load Current - Resistive 50 A, Reversing Capability Reversing, Overall Height 3.35 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2D38KUE
Availability: Ships in 18 days
SKU: GRG6047909 Category:

Analogues

ItemIEC Magnetic Contactor
Full Load Amps-Inductive38 A
Full Load Amps-Resistive50 A
Number of Poles3
Coil Volts100 to 250 V AC/DC
ReversingYes
HP @ 1 Phase - 120V2 hp
HP @ 1 Phase - 240V5 hp
Height3.35 in
Width3.54 in
HP @ 3 Phase - 208V10 hp
HP @ 3 Phase - 575V25 hp
Depth3.62 in
HP @ 3 Phase - 240V10 hp
HP @ 3 Phase - 480V20 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
Auxiliary Contact Form1NO/1NC
SeriesTeSys Deca
NEMA SizeNot Applicable
Electrical Durability1.8 Mcycles (35 A, AC-3, Less than 440 V), 0.9 Mcycles (50 A, AC-1, Less than 440 V)
Rated Voltage690V AC
Mechanical Durability15 Mcycles
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Rated Short-Time Withstand Current100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 150 A (at 40°C for 1 min Power Circuit), 310 A (at 40°C for 10 s Power Circuit)
FeaturesBuilt-In Bi-Directional Peak Limiting, Preassembled with Reversing Power Busbar
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Fire RatingUL 94 V1
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Electrical ConnectionScrew Clamp Terminals
Operating Speed3600 cycles per hr
Thermal Amperage10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)
Switching Voltage17 V (Signalling Circuit)
Max. Temperature850°C
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Inrush VA25 VA
Non-Overlap Time1.5 ms
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Max. Operating Watts9 kW (at 220 to 230V AC 50 Hz), 18.5 kW (at 380 to 400V AC 50 Hz), 18.5 kW (at 415V AC 50 Hz), 18.5 kW (at 440V AC 50 Hz), 18.5 kW (at 500V AC 50 Hz), 18.5 kW (at 660 to 690V AC 50 Hz)
Rated Insulation Volts690V
Working HeightUp to 9842.52 ft
Operating Time45 to 55 ms (Closing), 20 to 90 ms (Opening)
Includes Protective CoverYes
Impulse Withstand Voltage6 kV
Hold VA1.6 VA
Switching Current5 mA (Signalling Circuit)
Watts Loss1.1W
Mounts OnPlate, Rail
IP RatingIP20
Control Circuit Voltage LimitsDrop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC/DC: 0.85 to 1.1 Uc (at -40 to 60°C), 1 to 1.1 Uc (at 60 to 70°C)
Net Weight0.933 kg
Environmental AttributesMercury Free, Pollution Degree 3
Overvoltage CategoryCAT III
ApplicationMotor Control, Resistive Load
Signalling Circuit Frequency25 to 400 Hz
Impedance2 mOhm
Rated Breaking Capacity550 A @ 440V
Coil Voltage100-250V AC/DC
Horsepower @ Three Phase - 208V AC10 hp
Maximum Operating Temperature140 Degrees F
Frequency50/60 Hz
Resistance PropertiesFire Resistant, Insulation Resistant
Horsepower @ Three Phase - 600V AC25 hp
Maximum Voltage Rating690V AC
Reversing CapabilityReversing
Embedded Surge SuppressorNo
Number of Auxillary Contacts2
Contactor StyleIEC
Mounting StyleDIN Rail, Plate
NEMA Enclosure RatingNo Enclosure
Mechanical Operating Durability15,000,000
Full Load Current - Inductive38 A
Minimum Operating Temperature-40 Degrees F
Horsepower @ Three Phase - 480V AC20 hp
Horsepower @ Three Phase - 240V AC10 hp
Overall Height3.35 in
Overall Depth3.62 in
Number of Normally Open Main Contacts3
Horsepower @ Single Phase - 240V AC5 hp
Includes Auxiliary ContactsYes
NEMA Enclosure MaterialNot Applicable
Electrical Operating Durability1,800,000, 900,000
Horsepower @ Single Phase - 120V AC2 hp
Overall Width3.54 in
Terminal Connection TypeScrew Clamp Terminals
Full Load Current - Resistive50 A
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#100 to 250 V AC/DC
#38 A
#Reversing: Yes
#SCHNEIDER ELECTRIC
#Mfr LC2D38KUE
#SCHNEIDER ELECTRIC
#GRG6047909
#mfr:LC2D38KUE
#part number:LC2D38KUE
#pn:LC2D38KUE
#part code:LC2D38KUE
#item number:LC2D38KUE
#product code:LC2D38KUE
#manufacturer number:LC2D38KUE
#manufacturers part number:LC2D38KUE
#mfn:LC2D38KUE

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!