Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Full Load Amps-Resistive | 20 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 480 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 230V | 1 |
Height | 3.03 in |
HP @ 1 Phase - 240V | 1 hp |
HP @ 3 Phase - 208V | 2 hp |
Width | 1.77 in |
HP @ 3 Phase - 575V | 7 1/2 hp |
HP @ 3 Phase - 240V | 2 hp |
Depth | 3.38 in |
HP @ 3 Phase - 480V | 5 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Auxiliary Contact Form | 1NO/1NC |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Electrical Durability | 0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V), 2 Mcycles (9 A, AC-3e, Less than 440 V) |
Impulse Withstand Voltage | 6 kV |
Overvoltage Category | CAT III |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Net Weight | 0.32 kg |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Fire Rating | UL 94 V1 |
Working Height | Up to 9842.52 ft |
Application | Motor Control, Resistive Load |
Rated Breaking Capacity | 250 A @ 440V |
Watts Loss | 2 to 3W |
Signalling Circuit Frequency | 25 to 400 Hz |
Mechanical Durability | 15 Mcycles |
Inrush VA | 70 VA |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
IP Rating | IP20 |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Includes Protective Cover | Yes |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Switching Voltage | 17 V (Signalling Circuit) |
Thermal Amperage | 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Max. Temperature | 850°C |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Electrical Connection | Screw Clamp Terminals |
Rated Voltage | 690V AC, 300V DC |
Operating Speed | 3600 cycles per hr |
Tightening Torque | 1.7 Nm |
Mounts On | Plate, Rail |
Features | Without Built-In Suppressor Module |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Rated Insulation Volts | 600/690V |
Impedance | 2.5 mOhm |
Non-Overlap Time | 1.5 ms |
Fuse Amps | 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit) |
Maximum Operating Temperature | 140 Degrees F |
NEMA Enclosure Material | Not Applicable |
Phase | Three |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Horsepower @ Three Phase - 480V AC | 5 hp |
Number of Auxillary Contacts | 2 |
Coil Voltage | 480V AC |
Horsepower @ Three Phase - 208V AC | 2 hp |
Overall Width | 1.77 in |
Full Load Current - Resistive | 20 A |
Overall Depth | 3.39 in |
Horsepower @ Single Phase - 120V AC | 1/3 hp |
NEMA Enclosure Rating | No Enclosure |
Full Load Current - Inductive | 9 A |
Number of Normally Open Main Contacts | 3 |
Electrical Operating Durability | 2,000,000, 600,000 |
Terminal Connection Type | Screw Clamp Terminals |
Mechanical Operating Durability | 15,000,000 |
Maximum Voltage Rating | 690V AC |
Frequency | 50/60 Hz |
Embedded Surge Suppressor | No |
Mounting Style | DIN Rail, Plate |
Overall Height | 3.03 in |
Horsepower @ Three Phase - 240V AC | 2 hp |
Minimum Operating Temperature | -40 Degrees F |
Reversing Capability | Non-Reversing |
Resistance Properties | Fire Resistant, Insulation Resistant |
Includes Auxiliary Contacts | Yes |
Contactor Style | IEC |
Horsepower @ Single Phase - 240V AC | 1 hp |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 20 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Protective Cover | With |
IRMS Rated Making Capacity | 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Control Circuit Voltage | 480 V AC 50/60 Hz |
Minimum Switching Current | 5 mA for signalling circuit |
Protective Treatment | THIEC 60068-2-30 |
Motor Power KW | 2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3), 5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3), 2.2 kW at 400 V AC 50/60 Hz (AC-4), 2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 5.5 kW at 500 V AC 50/60 Hz (AC-3e), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Power Dissipation Per Pole | 1.56 W AC-1, 0.2 W AC-3, 0.2 W AC-3e |
Auxiliary Contact Composition | 1 NO + 1 NC |
Contact Compatibility | M2 |
Minimum Switching Voltage | 17 V for signalling circuit |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
Rated Short Time Withstand Current | 105 A 104°F (40°C) - 10 s for power circuit, 210 A 104°F (40°C) - 1 s for power circuit, 30 A 104°F (40°C) - 10 min for power circuit, 61 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Control Circuit Type | AC 50/60 Hz |
Conventional Free Air Thermal Current | 25 A (at 140°F (60°C)) for power circuit, 10 A (at 140°F (60°C)) for signalling circuit |
Pole Contact Composition | 3 NO |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Heat Dissipation | 2 to 3 W at 50/60 Hz |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Pollution Degree | 3 |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Poles Description | 3P |
Product Or Component Type | Contactor |
Compatibility Code | LC1D |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms) |
Maximum Horse Power Rating | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors |
Rated Operational Current | 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Connections - Terminals | Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end |
Utilisation Category | AC-4, AC-3, AC-1, AC-3e |
Mounting Support | Rail, Plate |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Contactor Application | Resistive load, Motor control |
IP Degree Of Protection | IP20 front face IEC 60529 |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Flame Retardance | V1 conforming to UL 94 |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Product Certifications | CSA, BV, GL, CCC, UL, GOST, LROS (Lloyds register of shipping), RINA, DNV, UKCA |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 480 V AC, 9 A, Reversing: No, SCHNEIDER, Mfr# LC1D09T7
$123,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC