Discount -3%

IEC Magnetic Contactor, 3 Poles, 120 V AC, 50 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D50AG7

$281,99
-$8.46 / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$281.99
Final shipping and tax calculated in checkout
Subtotal: $273.53 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D50AG7
Availability: Ships in 1 days
SKU: GRG1710055 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive50 A
ActionNon-Reversing
Full Load Amps-Resistive80 A
Number of Poles3
Coil Volts120 V AC
ReversingNo
HP @ 1 Phase - 120V3 hp
HP @ 1 Phase - 230V7-1/2
Height2.17 in
HP @ 1 Phase - 240V7 1/2 hp
HP @ 3 Phase - 208V15 hp
Width2.17 in
Depth4.61 in
HP @ 3 Phase - 575V40 hp
HP @ 3 Phase - 240V15 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V40 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Frame / Series / Class / CodeTeSys
IncludesEverlink Power Connections
SeriesTeSys Deca
NEMA SizeNot Applicable
Switching Current5 mA (Signalling Circuit)
Non-Overlap Time1.5 ms
FeaturesWithout Built-In Suppressor Module
Rated Voltage690V AC, 300V DC
Switching Voltage17 V (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Fuse Amps10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Electrical ConnectionScrew Clamp Terminals
Mounts OnPlate, Rail
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Includes Protective CoverYes
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Rated Short-Time Withstand Current400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Max. Temperature850°C
Signalling Circuit Frequency25 to 400 Hz
Fire RatingUL 94 V1
Inrush VA140 VA
IP RatingIP20
Max. Operating Watts15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz) , Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 60 Hz)
Watts Loss4 to 5W
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Overvoltage CategoryCAT III
Net Weight0.855 kg
Operating Speed3600 cycles per hr
Hold VA13 VA
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Rated Breaking Capacity900 A @ 440V
Impedance1.5 mOhm
Rated Insulation Volts600/690V
Mechanical Durability6 Mcycles
Working HeightUp to 9842.52 ft
Thermal Amperage10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Impulse Withstand Voltage6 kV
Electrical Durability1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
Electrical Operating Durability1,100,000, 1,450,000
Number of Auxillary Contacts2
Mechanical Operating Durability6,000,000
Resistance PropertiesFire Resistant, Insulation Resistant
Coil Voltage120V AC
Overall Width2.17 in
Overall Depth4.72 in
NEMA Enclosure RatingNo Enclosure
Frequency50/60 Hz
Horsepower @ Single Phase - 120V AC3 hp
Horsepower @ Three Phase - 600V AC40 hp
PhaseThree
Minimum Operating Temperature-40 Degrees F
Full Load Current - Inductive50 A
Overall Height4.8 in
Embedded Surge SuppressorNo
Full Load Current - Resistive80 A
Number of Normally Open Main Contacts3
Horsepower @ Three Phase - 240V AC15 hp
Includes Auxiliary ContactsYes
Maximum Voltage Rating690V AC
Maximum Operating Temperature140 Degrees F
Horsepower @ Single Phase - 240V AC7 1/2 hp
NEMA Enclosure MaterialNot Applicable
Horsepower @ Three Phase - 480V AC40 hp
Horsepower @ Three Phase - 208V AC15 hp
Reversing CapabilityNon-Reversing
Contactor StyleIEC
Mounting StyleDIN Rail, Plate
Terminal Connection TypeScrew Clamp Terminals
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Contactor ApplicationResistive load, Motor control
Insulation ResistanceGreater than 10 MOhm for signalling circuit
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 900 A at 440 V for power circuit conforming to IEC 60947
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 80 A (at 140°F (60°C)) for power circuit
Protective CoverWith
Pole Contact Composition3 NO
Mounting SupportRail, Plate
Auxiliary Contact Composition1 NO + 1 NC
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Product Or Component TypeContactor
Rated Short Time Withstand Current400 A 104°F (40°C) - 10 s for power circuit, 810 A 104°F (40°C) - 1 s for power circuit, 84 A 104°F (40°C) - 10 min for power circuit, 208 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Compatibility CodeLC1D
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Flame RetardanceV1 conforming to UL 94
Control Circuit TypeAC 60 Hz
Protective TreatmentTHIEC 60068-2-30
Minimum Switching Current5 mA for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Poles Description3P
Rated Operational Current50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Control Circuit Voltage120 V AC 60 Hz
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Power Dissipation Per Pole3.7 W AC-3, 9.6 W AC-1, 3.7 W AC-3e
Maximum Horse Power Rating3 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: solid without cable end
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Heat Dissipation4 to 5 W at 60 Hz
Product CertificationsDNV, GOST, UL, LROS (Lloyds register of shipping), GL, RINA, BV, CSA, CCC
Inrush Power in VA140 VA 60 Hz cos phi 0.75 (at 68°F (20°C))
Contact CompatibilityM2
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms)
Motor Power KW15 kW at 220 to 230 V AC 50/60 Hz (AC-3), 22 kW at 380 to 400 V AC 50/60 Hz (AC-3), 30 kW at 500 V AC 50/60 Hz (AC-3), 33 kW at 660 to 690 V AC 50/60 Hz (AC-3), 25 kW at 415 V AC 50/60 Hz (AC-3), 30 kW at 440 V AC 50/60 Hz (AC-3), 11 kW at 400 V AC 50/60 Hz (AC-4), 15 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 22 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 30 kW at 500 V AC 50/60 Hz (AC-3e), 33 kW at 660 to 690 V AC 50/60 Hz (AC-3e), 25 kW at 415 V AC 50/60 Hz (AC-3e), 30 kW at 440 V AC 50/60 Hz (AC-3e)
Fire Resistance1562°F (850°C) IEC 60695-2-1
Hold-In Power Consumption in VA13 VA 60 Hz cos phi 0.3 (at 68°F (20°C))
Rated Impulse Withstand Voltage6 kV IEC 60947
IP Degree Of ProtectionIP20 front face IEC 60529
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1
Pollution Degree3
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#120 V AC
#50 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D50AG7
#SCHNEIDER ELECTRIC
#GRG1710055
#mfr:LC1D50AG7
#part number:LC1D50AG7
#pn:LC1D50AG7
#part code:LC1D50AG7
#item number:LC1D50AG7
#product code:LC1D50AG7
#manufacturer number:LC1D50AG7
#manufacturers part number:LC1D50AG7
#mfn:LC1D50AG7